Additional Geotech Investigation 22.02.01 From Douglas Partners - 95120.01.R.001 · OPW21/0315
Page 5 of 6 It is generally preferable if an ‘ag lime’ with a purity of 95% or better is used (ie. NV >95, where NV is the neutralising value, a term used to rate the neutralising power of different forms of materials relative to pure, fine calcium carbonate which is designated NV = 100). The above lime dosing rates should be adjusted by a factor of 100/NV. 6. References Ahern, C R; Ahern, M R; Powell, B. (1998). Guidelines for Sampling and Analysis of Lowland Acid Sulfate Soils (ASS) in Queensland 1998. Resource Sciences Centre, Indooroopilly: Department of Natural Resources. Ahern, C. R., McElnea, A. E., & Sullivan, L. A. (2004). Acid Sulfate Soils Laboratory Methods Guidelines. In Queensland Acid Sulfate Soils Manual 2004. Indooroopilly, Queensland, Australia: Department of Natural Resources, Mines and Energy. Dear, S., Ahern, C., O'Brien, L., Dobos, S., McElnea, A., Moore, N., & Watling, K. (2014). Queensland Acid Sulfate Soil Technical Manual: Soil Management Guidelines. Brisbane: Department of Science: Department of Science, Information, Technology, Innovation and the Arts, Queensland Government. 7. Limitations Douglas Partners Pty Ltd (DP) has prepared this report for the proposed residence at 33 Wyuna Drive, Noosaville in accordance with DP’s proposal 95120.01.P.001 dated 30 November 2021. The work was carried out under DP’s Conditions of Engagement. This report is provided for the exclusive use of Braeden Constructions Pty Ltd for this project only and for the purposes as described in the report. It should not be used by or relied upon for other projects or purposes on the same or other site or by a third party. Any party so relying upon this report beyond its exclusive use and purpose as stated above, and without the express written consent of DP, does so entirely at its own risk and without recourse to DP for any loss or damage. In preparing this report DP has necessarily relied upon information provided by the client and/or their agents. The results provided in the report are indicative of the subsurface conditions on the site only at the specific sampling and/or testing locations, and then only to the depths investigated and at the time the work was carried out. Subsurface conditions can change abruptly due to variable geological processes and also as a result of human influences. Such changes may occur after DP’s field testing has been completed. DP’s advice is based upon the conditions encountered during this investigation. The accuracy of the advice provided by DP in this report may be affected by undetected variations in ground conditions across the site between and beyond the sampling and/or testing locations. The advice may also be limited by budget constraints imposed by others or by site accessibility. The assessment of atypical safety hazards arising from this advice is restricted to the geotechnical components set out in this report and based on known project conditions and stated design advice and assumptions. While some recommendations for safe controls may be provided, detailed ‘safety in Proposed Residence 95120.01.R.001.docx 33 Wyuna Drive, Noosaville February 2022
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Additional Geotech Investigation 22.02.01 From Douglas Partners - 95120.01.R.001.pdfRelated documentApplication case desk ↗
22.02.01 From Douglas Partners - 95120.01.R.001.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.