SCG 0187-CD- Issue 3 28.06.2024
DRAWING SIZE — At
HEIGHT DATUM
LOT 34 ON C 5603?
Level Datum AHD
Level Origin PM 24980
Wattle Street, Cooroy
[a
24
MAX WATTERSON + ASSOCIATES
Survey information provided by |
oO
LEGEND
_--7-77 INDICATES PROPOSED SURFACE
43077
+\80
CONTOURS AND LEVELS TO AHD.
EXISTING SURFACE SPOT LEVELS.
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
—_— w———_ INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
> ——_ INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES STORMWATER DRAIN EXISTING
AS NOTED
—— SW/EX
—_——_—— SLE SILT RETENTION FENCE TO DETAIL
www.dialbeforeyoudig.com.au
DIAL1100
BEFORE YOU DIG
COIR LOG OR HAY BALES PEGGED
INTO SURFACE. SPACED AT NO MORE
THAN 25m ALONG LENGTH OF TABLI
DRAIN
EXISTING STORMWATER
EXISTING SIDE ENTRY SILT FILTER SOCK TO SURROUND
EX. SWPT EXISTING STORMWATER PIT
EX. SMH
EXISTING SEWER MANHOLE
GRATED a GRATES AND SIDE ENTRY INTO EX. SCP EXISTING SEWER CONNECTION POINT
E.0.B. EXISTING EDGE OF BITUMEN
K &C EXISTING KERB & CHANNEL
So NS... NATURAL SURFACE LEVEL
FH. FIRE HYDRANT
TP TELSTRA PIT
EP. ELECTRICAL PILLAR
KERB _EXISTING KERBING
RCEW REINFORCED CONCRETE END WALL
EXISTING TABLE KERB & CHANNEL SV STOP VALVE
vovy DRAIN WM WATER METER
SILT FILTER SOCK DETAIL
PROVIDE SILT FENCE
COIR LOG CHECK DAM DETAIL AROUND INLET AS PER
' DETAIL ON THIS SHEET. +
= PROTECTION OF EXISTING STORMWATER PITS
av
ral aw
R SN
SS Sr ss a ee oe oe ee
+b
bk
N
LO a ee ee ee +
z 4 aT 7 | | | | | [ | T Ny a
_-=7 Peo | | __| |
= 2 | Steps| | | | se
bs | SPS | a
a T | 5 ___ | | te | X
3 | | 9 \ |
DB | ¥ | | |
& | Tr | no
2 || 1 | 7
B v | { |
< r | \ |
T | \ |
aa | |
7 TTS TT \ rs
| ~ | | ”
i \ » oy
= a | T . o T. eo
r -*re + KY XN . Vv
; taps qh l @signh
eg
| ve lp
| J
a
a |
He l
= iy.
4 2
A 5 |
\ 9
pe Me si -— — — — si Lit
+ WM
DUST MOBILISATION FROM WIND ACTION
SITE CONTROL TO INCLUDE PROTECTION AGAINST) |THE CARRIAGH OF
SOIL SEDIMENT FROM WIND ACTIONS. SITE FOREMAN TO COVER ALL
STOCKPILES WITH HESION OR SIMILIAR, PROVIDE HLT FENCING
AROUND BASE OF STOCKPILES
ALL SERVICES SHOWN ON THIS PLAN INDICATIVE
ONLY CONTRACTOR TO LOCATE ALL SERVICES
PRIOR TO COMMENCING WORKS ON SITE. ALL
SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY
RESPONSIBLE FOR THE SERVICE
SITE PLAN — SILT & SEDIMENT EROSION PLAN
Scale 1: 100 900(W) GEO-FABRIC SILT
FENCE, FIXED TO SPIKES
AND BURIED 300 INTO
STABLE GROUND.
SITE DRAINAGE — CONSTRUCTION
ENSURE GROUND PROFILE DURING CONSTRUCTION
FALLS TOWARDS THE CENTRE OF THE ALLOTMENT
THEN TOWARDS THE FRONT BOUNDARY WHERE
RUNOFF WILL DRAIN THROUGH THE SILT POND & SILT
FENCES. IN NO INSTANCE SHALL THE ALLOTMENT
DRAIN INTO NEIGHBOURING ALLOTMENTS.
SITE DRAINAGE — CONSTRUCTION
CONSTRUCTED STORM WATER PITS WITHIN THE SITE
ARE TO BE COVERED UNTIL THE SITE IS COMPLETED
OR TO BE FITTED WITH SILT PROTECTION MEASURES
TO THE APPROVAL OF THE ENGINEER
1200(L) 50 SQ. HDWD
SPIKES, 1800 CTRS DRIVE
600 INTO GROUND.
MAINTENANCE OF SILT PROTECTION
SITE FOREMAN TO MAINTAIN ALL SILT AND SEDIMENT PROTECTION
MEASURES THROUGHOUT THE DURATION OF THE PROJECT. ANY
BREACHING OF THE PROTECTION MEASURES MUST BE REMEDIATED
IMMEDIATELY AND REPORTED TO THE ENGINEER FOR CORRECTION
MEASURES. SILT RUNOFF PROTECTION IS TO BE MAINTAINED UNTIL
SUCH POINT THAT LANDSCAPING IS COMPLETED AND NOT
SUSCEPTABLE TO STORMWATER SCOUR.
——_—-
Yq SILT RETENTION
THE CONTRACTOR IS TO INSTALL APPROVED SILT
Ss RETENTION FENCES PRIOR TO COMMENCING ANY
° EARTHWORKS. THE FENCE IS TO BE CONSTRUCTED ALONG
THE LOWEST BOUNDARY AND RETURNED UP SIDE
BOUNDARIES TO ENSURE FULL STORMWATER ENTRAPMENT.
SURFACE RUNOFF FROM WITHIN THE ALLLOTMENT MUST
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECTURAL DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
ARCHITECTURAL DRAWINGS ARE TO BE REFERRED 10 THE
ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL
ENSURE THAT ALL NEW WORKS ARE IN ACCORDANCE WITH
THE ATTACHED CRITICAL DEPTH LINE DIAGRAM.
+>.
Revision | Description
Date
“FOR APPROVAL
the written permission of SCG Consulting Engineers.
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
C) St
ABN 68 669 675 790
SCG HOLDINGS PTY LTD T/
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
Title:
SILT & SEDIMENT EROSION
DRAIN TOWARDS THE FENCE AND SHALL NOT ENTER PLAN
NIEGHBOURING ALLOTMENTS THROUGH THE USE OF
SURFACE BUNDING OR SCOUR PROTECTED DRAINS. THE Project
FENCE MUST REMAIN IN PLACE UNTIL SUCH TIME THAT
FINISHED LANDSCAPING AND DRAINAGE MEASURES ARE 11 WATTLE ST,
SILT FENCE DETAIL — NSTALED COOROY
Date: Apri 24 Drawn 1H Design H
0 1 2 3 4 5 Checked: Drg No. Rev.
huuuuag-——L_+>——1__7m1:100 @ A1_—& ppeg 27698
1:200 @ A3 {| T Harrington 01 8/7 -OW2.1 .