Our ref: 170612/170901 Response to RFI 030418 abs
Council Ref: MCU17/0563


6 April 2018

Chief Executive Officer
Noosa Shire Council
PO Box 141
Tewantin QLD 4565

Attention:          Development Assessment – Lisa Pienaar
Via Email:          [email protected]

Dear Lisa,

Re:        Response to Information Request
           Proposed Material Change of Use (Multiple Housing – Type 2 Duplex)
           and Operational Works
           30 The Cockleshell, Noosaville
           Lot 11 on RP138550
           Council ref: MCU17/0563

I refer to Council’s Information Request, dated 10 January 2018 in relation to the
abovementioned development.

On behalf of the applicant, MJ Hussain & LH Randall & SM Johnson Cole & DA
Johnson, and in accordance with Part 3(13) of the DA Rules 2017, we provide a
response to all the issues raised. A response to the items raised in Councils
Information Request is outlined below:

      1.       A plan (to scale) that clearly details proposed R.L.s of the top of all roof
               lines.

RESPONSE
Please refer to Attachment 1 - Amended Architectural Plans prepared by Icon
Building Design, specifically Sheet 05, which demonstrates the RL of the roof line of
9.904 metres. Please see Figure 1 below, which details that the height of the building
does not exceed 8 metres from Natural Ground Level.




Figure 1 Building Height (Source: ICON Building Design)
Log in to download the original file

Response to RFI - Council.pdf · 4.9 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of pages 2 to 23 (of 34)

Page 2

    2.        A plan (to scale) that clearly demonstrates natural and finished ground surface levels. Include
              details of proposed fill levels.

RESPONSE
Please refer to the Amended Operational Works Plans prepared by 360 Civil Consulting Pty Ltd (Attachment
2), specifically Sheets 04 and 05 of 12, which demonstrates the earthworks plan and sections and
demonstrate the natural ground level, as well as the finished surface levels.

In addition to this, Sheet 05 of the Amended Architectural Plans (Attachment 1) also demonstrates the
natural and finished ground surface levels.




    3.        Provide amended plans that clearly demonstrate compliance with the required setbacks.

RESPONSE
Please refer to the Amended Architectural Plans (Attachment 1), specifically Sheet 03 (Section A), which
demonstrates compliant side setbacks to the ground and first levels (demonstrated in Figure 2 below). It is
noted that the unit design and setbacks are consistent for all units within the development and the identified
section below is sufficient to demonstrate compliance with the side boundary setback requirements.




  Building Setback Diagram




Figure 2 Building Setback Diagram (Source: ICON Building Design)



Although the development complies with the side and front boundary setbacks, the development remains non-
compliant with Probable Solution S9.1 of the Noosaville Locality Code, as the development contains a rear
boundary setback of 4.9 metres.

Despite this non-compliance, both adjoining sites are utilised for business purposes and will not be impacted,
nor will impact upon the proposed development within the setback variation, with 31 Thomas Street
containing a carpark to the rear of the site, and 33 Thomas Street containing a single storey building, which
does not include any outdoor functions between the built form and the boundary.

In consideration of the information provided above, the proposed development is compliant with Specific
Outcome O9, as:

Page 3

    •    The amenity of the residents is protected through the inclusion of screening and landscaping features;
    •    The development will not impact upon the amenity of adjoining development, given that the
         proposed development adjoins business uses within the Business Centre Zone;
    •    The development contains sufficient space for on-site car parking;
    •    The development includes setbacks, which are compliant with that of existing developments to the
         north and south of the subject site, which include setbacks of approximately 4.18 metres from the rear
         boundary; and,
    •    The setback variations do not result in any impacts to any mapped ecological features.

Accordingly, the development satisfies the setback Assessment Benchmarks outlined within the Noosaville
Locality Code.



    4.       Provide amended plans that have considered this and demonstrate compliance with the
             Noosaville Locality Code with respect to building design (particularly bulk), mix of materials,
             and considers the character of Noosaville and the local and surrounding streetscape.

RESPONSE
As demonstrated in the Amended Architectural Plans prepared by ICON Building Design (Attachment 1), the
development has been redesigned such that it presents a lightweight building design, which includes hip and
gable roof lines, timber cladding and variations in design. The revised design is reflective contemporary coastal
character of the surrounding area, will suitably integrate with the existing streetscape, and presents as a
considerable improvement where compared to the original design.

In addition to the variation to the architectural style, the redesign of the development has included design
variations between the two (2) building blocks, such that 30 and 32 The Cockleshell are not a mirror design.

As a result of the architectural re-design, the development complies with all assessment benchmarks of the
Noosaville Locality Code, specifically:

Probable Solution S21.1
Through the development utilising lightweight and textured external building materials.

Probable Solution S49.1
Through the development:
    •    Not exceeding a maximum wall length of 15 metres, and each wall pane contains an element which
         includes visual interest, specifically windows;
    •    Containing varied roof forms, with the use of hip and gable forms, which provide a point of difference
         between each building, it is noted that the units are stacked and do not present as individual units
         when viewed from the Cockleshell;
    •    Does not include upper level balconies, with ground level private open space provided for each unit;
    •    Visually breaks up the design through the application of different window and roof treatements, which
         visually reduces the bulk of the building; and,
    •    Utilises appropriate landscaping which is reflective of the proposed development and integrates with
         the streetscape.

Page 4

    5.       Provide amended plans that reduce the dominance and bulk of the fencing through innovative
             design and include a step-in design (maximum 5 metre intervals). Refer Item 4 of this
             information request.

RESPONSE
Please refer to the Amended Architectural Plans prepared by ICON Building Design (Attachment 1), which
demonstrates a varied fence design, such that no fence element contains a continuous section of more than 10
metres.



    6.       Provide information that provides details on practicalities of how the development will be
             accessed, whether it be an access easement, or other arrangement.

RESPONSE
Upon Approval of this Development Application, a subsequent Reconfiguring a Lot application will be lodged to
establish an Access Easement over the driveway and central vehicle manoeuvring areas.



    7.       Provide a stormwater strategy/layout that caters for the stormwater runoffs from adjoining
             properties and ensures no additional stormwater ponding or worsening of existing drainage
             conditions to occur on these properties for all storm events up and including 1% AEP (1 in 100
             year). This may require providing stormwater pipeline and/or defined overland secondary
             flowpath within the development site to convey natural stormwater runoff from other
             properties into an existing stormwater system.

RESPONSE
Please refer to the Engineering Response to Council’s Information Request (Attachment 3), as well as the
Amended Operational Works Plans prepared by 360 Civil Consulting Pty Ltd (Attachment 2), which responds to
Information Request Items 7 – 9. The specific response to Information Request Item 7 is detailed below:

   ‘Skyline Surveyors were able to provide additional survey, spot level information, on some areas of the
   neighbouring sites. This information is attached for Council’s record. Please note that in some locations
   access was not possible and Skyline obtained as best survey level information as possible. The survey
   information indicates the following: -
    •    Lot CP BUP7701 appears to have a ridge through the middle of the site with the western portion of
         the lot falling to the street and the eastern portion of the lot falling to the rear of the site. Possible
         pond may occur in the north-eastern corner of the proposed development site. In order to alleviate
         this possible ponding a side grated pit is proposed in the base level of the retaining wall which will be
         connected to the development site’s internal drainage. This stormwater system is shown on amended
         360 Civil Consulting Drawing No. 03 (Rev A).
    •    Lot 6 RP124554 has an internal stormwater pit and overland flow discharges to Thomas St via the
         existing driveway.
    •    Lot CP BUP7283 is lower than the development site and the survey levels indicate it falls towards
         Thomas St.
    •    Lot CP BUP6949 appears to be slightly lower than the development site and falls towards the street.
         The north-eastern corner of Lot CP BUP6949 appears to be approximately at a similar level to the
         development site and to address any possible ponding that may occur in this corner a side grated pit
         is proposed in the base level of the retaining wall which will be connected to the development site’s

Page 5

          internal drainage. This stormwater system is shown on amended 360 Civil Consulting Drawing No. 03
          (Rev A)’.



    8.         Provide further information, details and/or amendments to address the following:
                  a. The proposed development requires filling, increases load on the existing drainage
                      pipeline on the site and will limit future opportunities for repair and/or upgrade.
                      Also, there will be an increase in the flows in the pipeline due to the proposed
                      development. As such, it is considered necessary that CCTV investigation of the
                      existing pipeline (from The Cockleshell Street to Thomas Street) be carried out by
                      the applicant determine the condition of the pipeline and report of investigation
                      submitted to Council prior to issuing the OPW approval.
                  b. A drainage easement must be created by the applicant over the subject stormwater
                      pipeline at a width in compliance with Council’s standards and guidelines. Show the
                      required easement on the amended plans.



RESPONSE
Please refer to the Engineering Response to Council’s Information Request (Attachment 3), as well as the
Amended Operational Works Plans prepared by 360 Civil Consulting Pty Ltd (Attachment 2), which responds to
Information Request Items 7 – 9. The specific response to Information Request Item 8 is detailed below:

  a) ‘Please find attached to this response a preliminary stormwater CCTV report for the existing 375mm
     stormwater pipe that runs through 32 The Cockleshell, Noosaville. The CCTV commenced at The
     Cockleshell inlet pit and DrainsKleen have advised that "the survey was abandoned - camera travelled
     downstream about 7m, before reaching, root mass which camera could not pass. Attempted reverse
     survey from other end but unable to access pit."

         The report and photos from DrainsKleen of the root mass is attached for council's information. Further
         clarification from DrainsKleen regarding the reverse survey was sought and the DrainsKleen operator
         who was on site has advised that: -

         "I was unable to locate the downstream pit (unsure if downstream pit exists or is just cut into another
         pipe). I am also unable to go from one of the neighbour pits on Thomas Street as I can't go around
         corners with robot camera due to risk of damaging equipment."

         Since this survey, Council have advised that, in due course, they will unblock the stormwater pipe and
         that no further work by this development is required in order to address this information request item.

         Reviewing the photographs provided in the DrainsKleen report the pipe that is visible appears to be in a
         reasonable condition.

  b) Please refer to the amended 360 Civil Consulting Drawing No. 03 (Rev 3) which details the 4m wide
     drainage easement over the existing council stormwater infrastructure’.



    9.         Provide an engineering plan and longitudinal cross section for the access driveway/s and
               crossovers that include 2.0m wide pathway and demonstrates compliance with IPWEA

Page 6

               Standard Drawings RS-049 and RS-050 and have grades ensure a standard vehicle (B99),
               entering or leaving the site will not scrape or bottom down.

RESPONSE
Please refer to the Engineering Response to Council’s Information Request (Attachment 3), as well as the
Amended Operational Works Plans prepared by 360 Civil Consulting Pty Ltd (Attachment 2), which responds to
Information Request Items 7 – 9. The specific response to Information Request Item 9 is detailed below:

   ‘Please refer to the amended 360 Civil Consulting Drawing No. 11 and 12 which detail a driveway long
   section and relevant cross section drawings incorporating the 2m wide footpath and compliance with
   IPWEA Drawings RS-049 and RS-050’.



    10.        Provide amended landscaping plans that demonstrate compliance with the minimum
               landscaping requirements.

RESPONSE
Please refer to the Amended Architectural Plans (Attachment 1), specifically Sheet 2, which provides detail on
the soft and hard landscaping for each unit, as outlined below:

   30 the Cockleshell
          •   Soft Landscaping = 115.0m2 (45.18%)
          •   Hard Landscaping = 139.5m2 (54.81%)
          •   Total = 254.5m2

   32 the Cockleshell
    •     Soft Landscaping = 114.9m2 (45.21%)
    •     Hard Landscaping = 139.2m2 (54.78%)
    •     Total = 254.1m2

Overall, each unit block results in a minor shortfall in landscaping, with a shortfall of 9.5m2 for 30 The
Cockleshell and 9.9m2 for 32 The Cockleshell. Overall the development provides a total of 508m2 of
landscaped area, which equates to 42.2% of the consolidate site.

The development has mitigated the landscaping shortfall through providing the soft landscaping elements
to the frontage and rear of the site, as well as the adjoining northern and southern boundaries. Shortfalls to
the required landscaping are considered appropriate given the development is not able to provide
landscaping strips to the internal common boundary, given its required access arrangements. It is noted
that if the common internal boundary was capable of being landscaped, the development would comply
with the landscaping requirements. Thus, the provided landscaping strips on all other boundaries are of an
appropriate width to mitigate amenity impacts and integrate into the existing streetscape.

Despite the proposed non-compliance with Probable Solution S1.1 of the Landscaping Code, the
development satisfies Specific Outcomes O1, with the development providing sufficient landscaped area,
such that:
    •     The proposed landscaping enhances the visual amentiy and natural landscape character of the
          area, through the development containing a significantly improved streetscape, and through the
          inclusion of a mix of trees, shrubs and ground covers;

Page 7

        •     The existing Poinciana is required to be removed due to the central location of the tree and the
              required location of the driveway and maneuvering areas, all other vegetation is required to be
              removed, in place of new landscaping elements;
        •     The proposed landscaping assists in reducing the visual impact of the development and assists in
              concealing the carparking areas associated with the development, which are integrated into the
              design, such that they do not dominate the streetscape; and,
        •     The development contains sufficient separation and screening to adjoining development to the
              north and south, as well as appropriately screening the existing office development to the east.

Accordingly, the development satisfies the intent of Specific Outcome S1.1 of the Landscaping Code.



        11.       Provide an amended landscape plan which uses a local native species as a feature tree at the
                  frontage.

        12.       Provide an amended landscape plan with local native species in accordance with the landscape
                  and Planning Scheme Policy 3 landscaping Plants and Guidelines of the Noosa Plan.

        13.       Provide an amended landscape plan demonstrating sufficient volumes of planting media,
                  above ground volume and drainage for the proposed species.

RESPONSE
Please refer to the Amended Landscaping Plans provided by Element Design (Attachment 4). The Landscaping
Plans identify the use of a Banksia Integrifolia as the feature tree at the frontage of the site and incorporates a
native landscaping palette.



This response represents our complete response to the Information Request issued by the Noosa Council, and
we look forward to the decision notice being issued by Council in accordance with the relevant provisions of the
Planning Act 2016.

As always, please feel free to contact me direct should you require any additional information or clarification.

Yours faithfully,
ADAMS + SPARKES
TOWN PLANNING + DEVELOPMENT




Michael Lyell
SENIOR TOWN PLANNER

Encl:          Attachment 1 - Amended Architectural Plans prepared by ICON Building Design
               Attachment 2 - Operational Works Plans
               Attachment 3 - 360 Civil Consulting Response to IR
               Attachment 4 - Amended Landscape Plan
               Attachment 5 – CCTV Stormwater Footage prepared by Drains Kleen
               Attachment 6 – Additional Survey Data

Page 8

                                                                             Operational Works (Engineering) for
                                                                                     Proposed Duplexes
                                                                                             at
                                                                                 30-32 Cockleshell, Noosaville
                                                                                                                                                FOR
                                                                    A R & S M Johnson Coles & Dr D A Johnson
                                                                               (32 The Cockleshell)
                                                                         Dr L H Randall & Dr M J Hussain
                                                                               (30 The Cockleshell)

                                                       NOLAN
                                                               ST
                                                                                                                                                                                                           Drawing Schedule
                                                                                                                                 MARY
                                                                                                                                                                                                              DWG           DESCRIPTION
                                                                                                                                      ST
                                                                                                                                                                                                             2017115-01      Locality Plan and Schedule of Drawings
                                                                                                                                                                                                             2017115-02      Existing Features Plan
                                                                                                                                                                                                             2017115-03      Stormwater and Development Layout Plan
                                                                                                   LL




                                                                                                                                                                                                             2017115-04      Earthworks Plan
                                                                                                ESHE




                                                                                                                                                                                                             2017115-05      Earthworks Sections
                                                                                                                                                                                                             2017115-06      Driveway & Stormwater Setout Plan
                                                                                            OCKL




                                                      SYLVIA                                                                                                                                                 2017115-07      Pavement & Jointing Details Plan
                                                               ST
                                                                                                             SITE OF
                                                                                           THE C




                                                                                                                                                                                                             2017115-08      Sewer & Water Connection Plan
                                                                                                             WORKS                                                                                           2017115-09      Erosion & Sediment Plan
                                                                                                                                                                                                             2017115-10      Erosion & Sediment Control Details Plan
                                                                                                                                                                                                             2017115-11      Driveway Longitudinal Sections
                                                                                                                       AS ST




                                                                                                                                                                                                             2017115-12      Driveway Cross Sections
                                                                                                                      THOM




                                                               GIBSO
                                                                       N RD




                                                                                                                               GIBSO
                                                                                                                                       N RD

                                                                                                                                                                                                           RP Description
                                                                                                                                                                                                           Lot 11 RP138550 & Lot 0 BUP6971
                                                                                                                                                                                                           30-32 Cockleshell, Noosaville




                                                                                             LOCALITY PLAN
                                                                                                        N.T.S.




    360 CIVIL CONSULTING PTY LTD                                        No     Date                              Amendment
                                                                                                                                              Design:   J.A.G            FOR APPROVAL            CLIENT:     JOHNSON COLES, JOHNSON, RANDALL & HUSSAIN                 JOB NUMBER
                                                                         A    08-03-18 CHANGES AS PER COUNCIL RFI
                        ABN: 13 609 593 339                                                                                                   Drawn:    J.A.G                                    PROJECT:    PROPOSED DUPLEX DEVELOPMENT
BEATRICE GIBBERD RPEQ 14557 - DIRECTOR AND PRINCIPAL ENGINEER
                                                                                                                                                                                                                                                                           2017115
           23 OOGAR STREET, MAROOCHYDORE. QLD 4558                                                                                            Date:     04/11/17
                                                                                                                                                                   BEATRICE GIBBERD RPEQ 14557   AT:   30-32 COCKLESHELL, NOOSAVILLE
                                                                                                                                                                                                                                                                       DRAWING No:
   Mobile: 0403 862 009  Email: [email protected]                                                                            Checked: B.G.           DATE:    04/11/2017              LOT 11 ON RP138550 & 0 BUP6971
 THIS PLAN IS COPY PROTECTED BY 360 CIVIL CONSULTING PTY. LTD.
                                                                                                                                              Datum:    A.H.D.         Size:      A3             TITLE: LOCALITY PLAN AND DRAWING INDEX
                                                                                                                                                                                                                                                                        01 of 12

Page 9

                 EXISTING TELSTRA                                                                                                                                                                                                                                            LEGEND
                                                                                                                                                                                                                                                                         D   D   D   D   D
                                                                                                                                                                                                                                                                                             EXISTING STORMWATER
                 EXISTING                                                                                                                                                                                                                                                                    EXISTING SEWER MAIN
                 ELECTRICITY                                                                                                                                                                                                                                                                 EXISTING WATERMAIN
                                                                                                                                                                                                                                                                                             EXISTING ENERGEX - UNDERGROUND

                                                                                                                                                                                                                                  EXISTING SEWER                                             EXISTING TELSTRA
                                                                                                                                                                                                                                                                                             EXISTING CONTOURS
                                                                                                                                                                                                                                                                                             EXISTING SURFACE LEVELS




                                                                                                                                                                                                                                     EXISTING HCB'S
                               THE COCKLESHELL




                                                                                                EXISTING BUILDING




                                                                                                                                                                                                         SEWER MAIN
                EXISTING WATER
                                                                                                                                                                                                                                                   EXISTING STORMWATER




                                                                                                                                                                                              IL -0.21
                                                                                                                                                                                                                  SL 1.93
              EXISTING WATER                                                                                                                                                                                          IL -0.07    SEWER MAIN




                                                                                                                                                                                              IL -0.20
                                                                                                                                                                                                                                     EXISTING HCB


                                                                                                                                                                                                                                      EXISTING HCB
      EXISTING KERB AND CHANNEL                                                                                     EXISTING BUILDING




                                                                                                                                                                                                         SEWER MAIN
                                                                                                                                                                                                                                   EXISTING SEWER




                                                                                                                                                                                       CAUTION -
                                                                                                                                                                                       EXISTING SERVICES THE CONTRACTOR IS TO DETERMINE THE EXACT
                                                                                                                                                                                       LOCATION OF ALL EXISTING SERVICES IN THE VICINITY OF THE
                                                                                                                                                                                       PROPOSED WORKS PRIOR TO THE START OF ANY CONSTRUCTION.
                                                                                                                                                                                       THE COST OF ANY RECTIFICATION WORKS DUE TO DAMAGE TO
                                                                                                                                                                                       EXISTING SERVICES SHALL BE BORNE BY THE CONTRACTOR.



    360 CIVIL CONSULTING PTY LTD                                     No    Date                        Amendment
                                                                                                                                        Design:   J.A.G             FOR APPROVAL               CLIENT:                           JOHNSON COLES, JOHNSON, RANDALL & HUSSAIN                                      JOB NUMBER
                                                                     A    08-03-18 CHANGES AS PER COUNCIL RFI
                        ABN: 13 609 593 339                                                                                             Drawn:    J.A.G                                        PROJECT:                          PROPOSED DUPLEX DEVELOPMENT
BEATRICE GIBBERD RPEQ 14557 - DIRECTOR AND PRINCIPAL ENGINEER
                                                                                                                                                                                                                                                                                                                    2017115
           23 OOGAR STREET, MAROOCHYDORE. QLD 4558                                                                                      Date:     04/011/17
                                                                                                                                                              BEATRICE GIBBERD RPEQ 14557      AT:                      30-32 COCKLESHELL, NOOSAVILLE
                                                                                                                                                                                                                                                                                                                DRAWING No:
   Mobile: 0403 862 009  Email: [email protected]                                                                      Checked: B.G.            DATE:    04/11/2017                                    LOT 11 ON RP138550 & 0 BUP6971
 THIS PLAN IS COPY PROTECTED BY 360 CIVIL CONSULTING PTY. LTD.
                                                                                                                                        Datum:    A.H.D.          Size:      A3                TITLE: EXISTING FEATURES PLAN
                                                                                                                                                                                                                                                                                                                 02 of 12

Page 10

                    EXISTING TELSTRA                                                                                                                                                                                                                                                            LEGEND

                                                                                                                                                                                                                                                                                                                                     PROPOSED BUILDINGS
                    EXISTING
                    ELECTRICITY
                                                                        RETAINING WALL BY OTHERS -                                                                                                                                                                                                                                   PROPOSED DRIVEWAY
                                                                        REFER STRUCTURAL
                                                                        ENGINEERS DETAILS                                                                                                                                                                                                         D     D         D       D     D
                                                                                                                                                                                                                                                                                                                                     EXISTING STORMWATER
          EXISTING DRIVEWAY TO BE                                                                                                                                                                                                                          EXISTING SEWER
                                                                                                                                   MIN.FALL 1 IN 100 (TYP)                                                                                                                                                                           EXISTING SEWER MAIN
          REMOVED, KERB AND CHANNEL                                                                                                                                                                                                SWG
          AND VERGE TO BE REINSTATED                                                                                                                                                                                                                                                                                                 EXISTING WATERMAIN
          IN ACCORDANCE WITH COUNCIL                                                                                                                                                                                                                                                                                                 EXISTING ENERGEX - UNDERGROUND
          REQUIREMENTS
                                                                                                                                                                                                                                                                                                                                     EXISTING TELSTRA
                                    THE COCKLESHELL                                                                                                                                                                                                                                                                                  PROPOSED RETAINING WALLS
                                                                                                                                                           GP1         GP1                                                 GP1                                                                                                       (BY OTHERS)
                                                                                                                                                           FSL: 2.55   FSL: 2.55                                           FSL: 2.30                                                                                                 PROPOSED KERB ADAPTORS
                                                                                                                                                                                                                           IL:1.97
                                                                                                                                                                                                                                                                                                                                     PROPOSED 450 SURFACE GULLY
                                                                                                                                                                                                                                                                                                                          GP1        PIT WITH PIPE JUNCTION BOX

                                                                                                                                                                                                                                                                                                                                     PROPOSED SWG. SIDE ENTRY
                                                                              90mm DIA uPVC STORMWATER                                                                                                                                                                                                                    SWG        OVERLAND STORMWATER GRATE.
                                                                                                                                                                                                                                                                                                                                     REFER TO DETAIL
                                                                              CONNECTION. GRATED DRAIN TO
                                                                              CONNECT TO KERB ADAPTORS

                                                                                                     'ENTRY ONLY' SIGN
 NEW KERB ADAPTER IN
 ACCORDANCE WITH IPWEA STD
 DWG RS-081                                                                                      GP1
                                                                                                 FSL: 2.55
                                                      0.000



                                                              2.948




                                                                                                 IL:1.90
                                                                                                                                                                                                                                                                                                                                      CONCRETE SLEEPER
                                                                                                               LINEMARKING                                                                                                                       MIN.FALL 1 IN 100 (TYP)                                                              RETAINING WALL
 PROPOSED DRIVEWAYS AS PER




                                                                                                                                                                                                                                                                                                            RP BOUNDARY
 IPWEA STD DRG RS-049
 (TYPE 5) & RS-050
                                                                                                                                                                                                                                                                                                                                      FILLED ALLOTMENT
                                                                                                10.000




                                                                                                                                                 20.000




                                                                                                                                                                                     28.311
   EXISTING WATER                                                                                                                                                                                                                                                                                                                         FSL
                                                                                                                                                                                                                           GP1
   METER TO BE                                                                                                                                                                                                                                          STORMWATER EASEMENT
                                                                                                                                                                                                                           FSL: 2.30
   RELOCATED
                                                                                                                                                                                                                           IL:1.86                                               NEIGHBOURING ALLOTMENT
                                                                                                         DRIVEWAY 1                                                                                                                                                                             NSL                                       NSL
                       'NO ENTRY' SIGN




                                                                                                                                                                                                                                         4.00m
                                                                                                                                                                                                                                                  EXISTING STORMWATER            BOTTOM WALER
EXISTING SW PIT                                                                                                                                                                                                                                                                  REPLACED WITH TRENCH                                 STORMWATER PIPE SET BELOW
                                                                                                10




SL:1.68                                                                               2                                                                                                                                                                                          GRATE LAID ON SIDE                                   N.S. TO ACHIEVE 1:100 FALLS
                                                                                                   .




                                                                                 AY
                                                                                                     00




IL:0.68                                                                      W                                                                                                                                 GP1
                                                                           VE
                                                                                                        0




                                                                          I                                                                                                                                    FSL: 2.30
EXISTING WATER                                                         DR                                                                        PROPOSED FIELD INLET PIT                                                                                                                             SIDE ELEVATION
                                                                                                                                                                                                                                                                                                                                      CONCRETE SLEEPER
METER TO BE                                                                                                    LINEMARKING                       (TYPE 2B) TO CONNECT TO COUNCIL'S                             IL:1.86                                                                                                                RETAINING WALL
RELOCATED                                                                                                                                        STORMWATER PIPE. AS PER IPWEA STD DRG DS-050                                                                                                                             1000 MIN
                                                                         'EXIT ONLY' SIGN                                                        SL:2.40
PROPOSED DRIVEWAYS AS PER
                                                                                                                                                                                                                                                  MIN.FALL 1 IN 100 (TYP)
IPWEA STD DRG RS-049                                                                               GP1
(TYPE 5) & RS-050                                                                                  FSL: 2.30
                                                                                                   IL:1.90
 NEW KERB ADAPTER IN
 ACCORDANCE WITH IPWEA STD
 DWG RS-081                                                                                                                                                                                                                                                                                                                               200 (H) TRENCH GRATE
                                                                                      90mm DIA uPVC STORMWATER                                                                                                                                                                                                                            LAID ON SIDE IN PLACE OF
                                                                                                                                                                                                                                                                                                                                          BOTTOM WALL EXTEND
                                                                                      CONNECTION. GRATED DRAIN TO                                                                                                                                                                                           FRONT ELEVATION               100mm PAST POSTS
                                                                                      CONNECT TO KERB ADAPTORS
       EXISTING DRIVEWAY TO BE                                                                                                                                                                                                                               EXISTING SEWER
       REMOVED, KERB AND CHANNEL
       AND VERGE TO BE REINSTATED
       IN ACCORDANCE WITH COUNCIL                                                                                                                         GP1            GP1                                                                                                                  SCALE 1:60 (A3)
                                                                                                                                 UP                                                            UP                          GP1
       REQUIREMENTS                                                                                                                                       FSL: 2.55      FSL: 2.55                                         FSL: 2.30
                                                                                                                                                                                                                                                                                            SWG'S TO BE LOCATED ADJACENT TO LOW POINT IN
                                                                                                                                                                                                                           IL:1.97                                                          NEIGHBOURING ALLOTMENT TO CAPTURE PONDING CAUSED BY
                                                                                                                                                                                                                                                                                            RETAINING WALL CONSTRUCTION REFER DETAIL


       PROPOSED 2.0m FOOTPATH AS
       PER IPWEA STD DRG RS-065
                                                                                                                                                                                                                                   SWG
                                                                      2.00m
        EXISTING KERB AND CHANNEL
                                                                                                                             MIN.FALL 1 IN 100
                                                                                                                             (TYP)                                                                                                                                                   CAUTION -
                                                                                                                                                                                                                                                                                     EXISTING SERVICES THE CONTRACTOR IS TO DETERMINE THE EXACT
                                                                                                                                                                                                                                                                                     LOCATION OF ALL EXISTING SERVICES IN THE VICINITY OF THE
                                                                                                                                                                                                                                                                                     PROPOSED WORKS PRIOR TO THE START OF ANY CONSTRUCTION.
                                                                                                                                                                                                                                                                                     THE COST OF ANY RECTIFICATION WORKS DUE TO DAMAGE TO
                                                                                                                                                                                                                                                                                     EXISTING SERVICES SHALL BE BORNE BY THE CONTRACTOR.




    360 CIVIL CONSULTING PTY LTD                                                           No    Date                        Amendment
                                                                                                                                                                                     Design:   J.A.G             FOR APPROVAL              CLIENT:       JOHNSON COLES, JOHNSON, RANDALL & HUSSAIN                                                      JOB NUMBER
                                                                                           A    08-03-18 CHANGES AS PER COUNCIL RFI
                        ABN: 13 609 593 339                                                                                                                                          Drawn:    J.A.G                                       PROJECT:      PROPOSED DUPLEX DEVELOPMENT
BEATRICE GIBBERD RPEQ 14557 - DIRECTOR AND PRINCIPAL ENGINEER
                                                                                                                                                                                                                                                                                                                                                            2017115
           23 OOGAR STREET, MAROOCHYDORE. QLD 4558                                                                                                                                   Date:     04/11//17
                                                                                                                                                                                                           BEATRICE GIBBERD RPEQ 14557     AT:      30-32 COCKLESHELL, NOOSAVILLE
                                                                                                                                                                                                                                                                                                                                                        DRAWING No:
   Mobile: 0403 862 009  Email: [email protected]                                                                                                                   Checked: B.G.            DATE:    04/11/2017                   LOT 11 ON RP138550 & 0 BUP6971
 THIS PLAN IS COPY PROTECTED BY 360 CIVIL CONSULTING PTY. LTD.
                                                                                                                                                                                     Datum:     A.H.D.         Size:         A3            TITLE: STORMWATER AND DEVELOPMENT LAYOUT PLAN
                                                                                                                                                                                                                                                                                                                                                         03 of 12

Page 11

                                                                                                                                                                                                                                                                                                             LEGEND
                                                                                                                                                                                                                                                                                                                                         PROPOSED CUT

                                                                        CONCRIB/BLOCK RETAINING                                                                                                                                                                                                                                          PROPOSED FILL
                                                                        WALL (OR EQUIVALENT) BY
                                                                        OTHERS - REFER STRUCTURAL                                                                                                                                                                                                             D   D   D   D   D
                                                                                                                                                                                                                                                                                                                                         EXISTING STORMWATER
                                                                        ENGINEERS DETAILS




                                                                                                                                                        A
                                                                                                                                                                                                                                                                                                                                         EXISTING SEWER MAIN

                                                      TW 2.40                                                                                TW 2.55                                                                                       TW 2.55                                                                                       EXISTING WATERMAIN
                                                      NSL 1.85                                                                               NSL 1.93                                                                                      NSL 1.97                                                                                      EXISTING ENERGEX - UNDERGROUND
                                                                                                                                                                                                                                                                                                                                         EXISTING TELSTRA

                                                                                                                                                                                                                                                                                                                                         PROPOSED RETAINING WALL
                                                                                                                                                             FSL 2.55                                                                                                                                                                    (BY OTHERS)
                                                                                                                                                                                                                                                                                                                                  4.00   PROPOSED CONTOURS




                                                                                                                                                    FFL 2.70
                                                                                                                                                    PAD 2.40                                                                                           TW 2.55
                                                                                                                                                                                                                          FSL 2.55        FSL 2.40     NSL 1.80
                                                                             FSL 2.40            FSL 2.55

                                                                                                                                                                                                                                                           C                                 EARTHWORKS QUANTITIES
                              05                     TW 2.40
                                                     NSL 1.79
                                                                                                                              FSL 2.65                                            FSL 2.65                                                                                                   TOPSOIL STRIP:




                                                                                                                                                            8.3%
                                                                                                                                                                                                                                                                                             EARTHWORKS CUT:
                                                                                                                                                                                                                                                                                             FILL REQUIRED:
                                                                                                                                         FSL 2.48                             FSL 2.48                                                                                                       DEFICIT:
                                                                                                                         FSL 2.55                                                                       FSL 2.55
                                                                            TW 2.40                                                                                                                                                                                                          NOTES:
                                                                            NSL 1.90




                                                                                                                                                            1.4%
                                                                                                                                                                                                                                                                                              1.  ALL VOLUMES INDICATED ARE SOLID VOLUMES.
                                                                                                                                                                                                                                                                                              2. ASSUMED TOPSOIL STRIP AT 150mm THICK.
                                                                                                                                                                                                                                                                                              3. EARTHWORKS QUANTITIES BASED ON COMPARISON BETWEEN
                                                                                                                                                                                                                                                                                                  EARTHWORKS/ BOXING LEVELS AND NATURAL SURFACE.
                                                                                                                                                                                                                                                       TW 2.55
                                                                                                                                                                                                                                                       NSL 2.30
                                                                                                              FSL 2.30                                                         FSL 2.45
                                                                                                                                           SL 2.40

                                                                            TW 2.40                                                                                                                                                                                                            EARTHWORKS NOTES
                                                                            NSL 2.11




                                                                                                                                                     2.4%
                                                                                                                                                                                                                                                                                                   1.    CONTROL TESTING OF EARTHWORKS TO BE IN
                                                                                                                        FSL 2.55                                                                        FSL 2.55                                                                                   ACCORDANCE WITH AS3798-1996, WITH LEVEL 1 GEOTECHNICAL
                                                                                                                                                                                                                                                                                                   CERTIFICATION.
                                                                                                                                         FSL 2.48                             FSL 2.48
                                                     TW 2.40                                                                                                                                                                                                                                       2     ALL DRAINAGE, EROSION AND SEDIMENT CONTROLS TO BE




                                                                                                                                                     8.3%
                                                     NSL 1.94                                                                                                                                                                                                                                      INSTALLED AND FULLY OPERATIONAL BEFORE COMMENCING
                                                                                                                              FSL 2.65                                           FSL 2.65                                                                                                          UP-SLOPE EARTHWORKS.

                                                                                                                                                                                                                                                       TW 2.55                                     3   ALL EXISTING UNDERGROUND SERVICES TO BE LOCATED AND
                                                                                                                                                                                                                                                       NSL 3.30                                    MARKED PRIOR TO COMMENCING EARTHWORKS.
                                                                             FSL 2.40            FSL 2.55                                                                                                                 FSL 2.55        FSL 2.40
                                                                                                                                                    FFL 2.70                                                                                                                                       4.    FILL DENSITY TESTING SHALL CONFORM TO THE
                                                                                                                                                    PAD 2.40                                                                                                                                       FOLLOWING:
                                                                                                                                                                                                                                                       B                                                       a. 1 TEST PER 500 cu.m - GENERALLY
                              05
                                                                                                                                                                                                                                                                                                               b. 1 TEST PER 2 LAYERS PER 40m - TRENCH
                                                                                                                                                                                                                                                                                                                   BACKFILL
                                                                                                                                                                                                                                                                                                   5      PLACEMENT OF FILL SHALL CONFORM TO THE FOLLOWING
                                                                                                                   UP                                                                              UP
                                                                                                                                                                                                                                                                                                          MINIMUM DRY DENSITY RATIO (M.D.D.R.) COMPACTION
                                                                                                                                                                                                                                                                                                          STANDARDS:
                                                                                                                                                                                                                                                                                                               c.  ALLOTMENTS = 98% STD
                                                                                                                                                                                                                                                                                                               d. ROAD VERGES/EMBANKMENTS = 98% STD
                                                                                                                                                                   FSL 2.55                                                                                                                                    e. PAVEMENT SUBGRADE = 100% STD FOR
                                                                                                                                                                                                                                                                                                                   NON-COHESIVE MATERIALS, M.D.D.R. = 80%

                                                                 TW 2.40                                                                 TW 2.55                                                                                            TW 2.55                                                5.      ALL ALLOTMENTS OR AREAS SUBJECT TO EARTHWORKS
                                                                 NSL 1.92                                                                NSL 2.11                                                                                           NSL 2.00                                               ARE TO BE FREE DRAINING WITH A MINIMUM SLOPE OF 1:100.

                                                                                                                                                                                                                                                                                                   6.     ALL TEMPORARY STOCKPILES (IF APPLICABLE) TO HAVE 1:6
                                                                                                                                                                                                                                                                                                   MAXIMUM SIDE BATTERS (GRASS SEEDED).

                                                                                                                                                                                                                                                                                                   7.    ALL WORK TO BE STRICTLY IN ACCORDANCE WITH
                                                                                                                                                                                                                                                                                                   STANDARD EARTHWORKS SPECIFICATION.
                                                                                                                                                                                                                                CAUTION -
                                                                                                                                                        05




                                                                                                                                                                                                                                EXISTING SERVICES THE CONTRACTOR IS TO DETERMINE THE EXACT
                                                                                                                                                                                                                                LOCATION OF ALL EXISTING SERVICES IN THE VICINITY OF THE
                                                                                                                                                                                                                                PROPOSED WORKS PRIOR TO THE START OF ANY CONSTRUCTION.
                                                                                                                                                                                                                                THE COST OF ANY RECTIFICATION WORKS DUE TO DAMAGE TO
                                                                                                                                                                                                                                EXISTING SERVICES SHALL BE BORNE BY THE CONTRACTOR.



    360 CIVIL CONSULTING PTY LTD                                             No    Date                        Amendment
                                                                                                                                                                                         Design:   J.A.G                 FOR APPROVAL                      CLIENT:    JOHNSON COLES, JOHNSON, RANDALL & HUSSAIN                                             JOB NUMBER
                                                                             A    08-03-18 CHANGES AS PER COUNCIL RFI
                        ABN: 13 609 593 339                                                                                                                                              Drawn:    J.A.G                                                   PROJECT:   PROPOSED DUPLEX DEVELOPMENT
BEATRICE GIBBERD RPEQ 14557 - DIRECTOR AND PRINCIPAL ENGINEER
                                                                                                                                                                                                                                                                                                                                                               2017115
           23 OOGAR STREET, MAROOCHYDORE. QLD 4558                                                                                                                                       Date:     04/11/17
                                                                                                                                                                                                                   BEATRICE GIBBERD RPEQ 14557             AT:    30-32 COCKLESHELL, NOOSAVILLE
                                                                                                                                                                                                                                                                                                                                                              DRAWING No:
   Mobile: 0403 862 009  Email: [email protected]                                                                                                                       Checked: B.G.                DATE:    04/11/2017                         LOT 11 ON RP138550 & 0 BUP6971
 THIS PLAN IS COPY PROTECTED BY 360 CIVIL CONSULTING PTY. LTD.
                                                                                                                                                                                         Datum:    A.H.D.              Size:         A3                    TITLE: EARTHWORKS PLAN
                                                                                                                                                                                                                                                                                                                                                               04 of 12

Page 12

                                                                                                                                                                                                                                                   RP BDY
                                                                                                                           DUPLEX                             DRIVEWAY                                          DUPLEX




                                                                                             RP BDY
                                                                                                                           FFL 2.70                                                                             FFL 2.70


                                                                                                                                                            DESIGN SURFACE

                                                                                                                                           SECTION A                                                                                 EXISTING SURFACE
                                                                                                                                      04    SCALE 1:200




                                                                                            RP BDY




                                                                                                                                                                                                                                          RP BDY
                                                                                                                                                          DUPLEX

                                                 RETAINING WALL BY OTHERS -
                                                 REFER STRUCTURAL
                                                 ENGINEERS DETAILS

                                                                                                                                                          FFL 2.70
                                                           COCKELSHELL


                                                                                                                                                                                               DESIGN SURFACE
                                                                                                                                                                                                                                                                     RETAINING WALL BY OTHERS -
                                                                                                                                                                                                                                                                     REFER STRUCTURAL
                                                                                                                                           SECTION B                                    EXISTING SURFACE
                                                                                                                                                                                                                                                                     ENGINEERS DETAILS
                                                                                                                                      04    SCALE 1:200
                                                                                                      RP BDY




                                                                                                                                                                                                                                                            RP BDY
                                                                                                                                                                       DUPLEX

                                                      RETAINING WALL BY OTHERS -
                                                      REFER STRUCTURAL
                                                      ENGINEERS DETAILS
                                                                                                                                                                       FFL 2.70
                                                           COCKELSHELL

                                                                                                                                                                                               DESIGN SURFACE
                                                                                                                                                                                                                                                                          RETAINING WALL BY OTHERS -
                                                                                                                                                                                                                                                                          REFER STRUCTURAL
                                                                                                                                           SECTION C                                    EXISTING SURFACE
                                                                                                                                                                                                                                                                          ENGINEERS DETAILS
                                                                                                                                      04    SCALE 1:200




    360 CIVIL CONSULTING PTY LTD                                      No      Date                             Amendment
                                                                                                                                                Design:      J.A.G                      FOR APPROVAL                 CLIENT:    JOHNSON COLES, JOHNSON, RANDALL & HUSSAIN                              JOB NUMBER
                                                                      A    08-03-18 CHANGES AS PER COUNCIL RFI
                        ABN: 13 609 593 339                                                                                                     Drawn:       J.A.G                                                   PROJECT:   PROPOSED DUPLEX DEVELOPMENT
BEATRICE GIBBERD RPEQ 14557 - DIRECTOR AND PRINCIPAL ENGINEER
                                                                                                                                                                                                                                                                                                        2017115
           23 OOGAR STREET, MAROOCHYDORE. QLD 4558                                                                                              Date:        04/11/17
                                                                                                                                                                                  BEATRICE GIBBERD RPEQ 14557        AT:   30-32 COCKLESHELL, NOOSAVILLE
                                                                                                                                                                                                                                                                                                       DRAWING No:
   Mobile: 0403 862 009  Email: [email protected]                                                                              Checked: B.G.                        DATE:    04/11/2017                   LOT 11 ON RP138550 & 0 BUP6971
 THIS PLAN IS COPY PROTECTED BY 360 CIVIL CONSULTING PTY. LTD.
                                                                                                                                                 Datum:       A.H.D.                  Size:      A3                  TITLE: EARTHWORKS SECTIONS
                                                                                                                                                                                                                                                                                                        05 of 12

Page 13

                                                                                                                                                                                                                                                                                          LEGEND
                                                                                                                                                                                                                                                                                                                      PROPOSED DRIVEWAY
                                                                                                                                                                                                                                                                                                                      150 THICK N32 CONCRETE
                                                                                                                                                                                                                                                                                          D     D   D     D    D
                                                                                                                                                                                                                                                                                                                      EXISTING STORMWATER
                                                                                                                                                                                                                                                                                                                     EXISTING SEWER MAIN
                                                                                                                                                                                                                                                                                                                     EXISTING WATERMAIN
                                                                                                                                                                                                                                                                                                                     EXISTING ENERGEX - UNDERGROUND
                                                                                                                                                                                                                                                                                                                     EXISTING TELSTRA
                                                                                                                                                                                                                                                                                                                     PROPOSED KERB ADAPTORS
           THE COCKLESHELL




                                                                                                                                                                                                                                                                                                                     AND ROOF WATER CONNECTION
                                                            1.50m   1.50m        0.59m
                                                                                                                                                                                                                                                                                                                     SAW CUT JOINT
                                                                                                                                                                                                                                                                                                                     (REFER DWG 07 FOR DETAILS)
                                                                                                                                                                                                                                                                                                                     EXPANSION JOINT
                                                                                                                                                                                                                                                                                                                     (REFER DWG 07 FOR DETAILS)
                                                                                         4                                                                                                         FSL 2.65                                                                  FSL 2.65


                                        1                       2           3
                                                                                                                                                                                                                                                                                              SETOUT POINTS
                             4.00m




                                                            12.5%    2.5%        5.0%
                                                                                         4.95m
                                                                                                                                                                                                                                                                                                    No,            LEVEL    *
                                                                                                                                                                                                                                                                                                          1         1.566

PROPOSED DRIVEWAYS                                                                                                              5                                                                                                                                                                         2         1.753
AS PER IPWEA STD DRG
RS-049 (TYPE 5) & RS-050                                        7                                 5.5%
                                                                                                                                                                                                                                                                                                          3         1.791

                                                                                                                                                                                                                                                                                                          4         1.821
                                                                        8                                                                                                                                                                                                                                 5         2.175

                                                                                                                                                                                                                                                                                                          6         1.533
                                                    1.73m




                                                                                            9                                                                                                                                                                                                             7         1.721

                                                                                                                                                                                                                                                                                                          8        1.758
                                                                                                                                     19                                 FSL 2.30                                                                                       FSL 2.50
                                                                                                                                                                                                                                                                                                          9        1.788

                                                                                                                                                                                                                                                                                                          10       1.535

                                                                                                                                                                                                                                                                                                          11       1.722
                                                                                                                                                                                                                                     SL 2.40
                                                                                                                                                                                                                                                                                                          12        1.760

                                                                                                                                                                                                                                                                                                          13        1.790
                                            0.70m




                                                                                                                                     18                                                                                                                                                                   14        1.564
                                                                                                 5.3%                                                                                                                                                                                                     15        1.751

                                                                                                                                                                                                                                                                                                          16        1.789

                                       10                      11                                                                                                                                                                                                                                         17        1.819

                                                                                                                                                                                                                                                                                                          18        2.182

                                                                                                                                                                                                                                                                                                          19        2.132
                                                                                         4.95m




                                                                                                                                                                                                                                                                                              * REPRESENTS FINISHED CONCRETE LEVEL
                             4.00m




                                                            12.5%    2.5%        5.0%



PROPOSED DRIVEWAYS
AS PER IPWEA STD DRG                                                                                                                                                                                                                                                                          125mm THICK N32 CONCRETE
RS-049 (TYPE 5) & RS-050               14                      15                                                                                                                                 FSL 2.65                                                                 FSL 2.65           WITH SL72 MESH



                                                                                16       17


                                                                                                                                                                                                                                    NOTES
                                                                                                                                                                                                                                      1.    DRIVEWAY AND CROSSOVER TO BE CONSTRUCTED IN
                                                                                                                                                                                                                                      ACCORDANCE WITH IPWEAQ STD DRG RS-049 & RS-050
                                                                                                                                                                                                                                      2.    ALL ROOFWATER AND STORMWATER TO DISCHARGE
                                     CAUTION -                                                                                                                                                                                        TO NEW KERB ADAPTORS AND DRIVEWAY STORMWATER PIT
                                     EXISTING SERVICES THE CONTRACTOR IS TO DETERMINE THE EXACT                                                                                                                                       3.    DRIVEWAY SET OUR TO BE INSPECTED BY AN RPEQ
                                     LOCATION OF ALL EXISTING SERVICES IN THE VICINITY OF THE                                                                                                                                         PRIOR TO POUR.
                                     PROPOSED WORKS PRIOR TO THE START OF ANY CONSTRUCTION.                                                     NOTE:                                                                                 4.     ALL VERGE AREAS TO TIE BACK INTO EXISTING
                                     THE COST OF ANY RECTIFICATION WORKS DUE TO DAMAGE TO                                                       FOR BUILDING SETOUT REFER TO ARCHITECTS DRAWINGS
                                     EXISTING SERVICES SHALL BE BORNE BY THE CONTRACTOR.




      360 CIVIL CONSULTING PTY LTD                                                               No    Date                         Amendment
                                                                                                                                                                             Design:   J.A.G                    FOR APPROVAL        CLIENT:    JOHNSON COLES, JOHNSON, RANDALL & HUSSAIN                                            JOB NUMBER
                                                                                                 A    08-03-18 CHANGES AS PER COUNCIL RFI
                         ABN: 13 609 593 339                                                                                                                                 Drawn:    J.A.G                                        PROJECT:   PROPOSED DUPLEX DEVELOPMENT
 BEATRICE GIBBERD RPEQ 14557 - DIRECTOR AND PRINCIPAL ENGINEER
                                                                                                                                                                                                                                                                                                                                     2017115
            23 OOGAR STREET, MAROOCHYDORE. QLD 4558                                                                                                                          Date:     04/11/17
                                                                                                                                                                                                      BEATRICE GIBBERD RPEQ 14557   AT:   30-32 COCKLESHELL, NOOSAVILLE
                                                                                                                                                                                                                                                                                                                                    DRAWING No:
    Mobile: 0403 862 009  Email: [email protected]                                                                                                          Checked: B.G.                   DATE:    04/11/2017          LOT 11 ON RP138550 & 0 BUP6971
  THIS PLAN IS COPY PROTECTED BY 360 CIVIL CONSULTING PTY. LTD.
                                                                                                                                                                             Datum:    A.H.D.                 Size:      A3         TITLE: DRIVEWAY AND STORMWATER SETOUT PLAN
                                                                                                                                                                                                                                                                                                                                        06 of 12

Page 14

      SUGGESTED EXPANSION JOINT METHOD FOR CONTINUOUS POURING

      CONSTRUCTION NOTES AND METHODS
                                                                                                                                 SAW CUT JOINT                                                                                                ISOLATION JOINT
                                                                                                                                (CONTROL JOINT)
                                                                                                                    (Maximum spacing; 4m)




                                                                                                                                                                                                                                FORMED JOINT (WITH SHEAR KEY)
                                                                                                                   EXPANSION JOINT                                                                                                    (CONTROL JOINT)
                                                                                                                                                                                                                               (Maximum spacing; 100mm thick 2m / 150mm thick 4m)
                                                                                                                   (Maximum spacing 12m)




                         MESH COVER




                  DOWEL BAR SCHEDULE




                                                                                                                                                              TYPICAL PROFILE DRIVEWAY ACCESS
                                                                                                                                                                       (EXTRACT FROM IPWEAQ STD DRAWING RS-050)




    360 CIVIL CONSULTING PTY LTD                                     No    Date                        Amendment
                                                                                                                                           Design:   J.A.G             FOR APPROVAL                    CLIENT:    JOHNSON COLES, JOHNSON, RANDALL & HUSSAIN                         JOB NUMBER
                                                                     A    08-03-18 CHANGES AS PER COUNCIL RFI
                        ABN: 13 609 593 339                                                                                                Drawn:    J.A.G                                             PROJECT:   PROPOSED DUPLEX DEVELOPMENT
BEATRICE GIBBERD RPEQ 14557 - DIRECTOR AND PRINCIPAL ENGINEER
                                                                                                                                                                                                                                                                                     2017115
           23 OOGAR STREET, MAROOCHYDORE. QLD 4558                                                                                         Date:     04/11/17
                                                                                                                                                                 BEATRICE GIBBERD RPEQ 14557           AT:    30-32 COCKLESHELL, NOOSAVILLE
                                                                                                                                                                                                                                                                                    DRAWING No:
   Mobile: 0403 862 009  Email: [email protected]                                                                         Checked: B.G.            DATE:    04/11/2017                       LOT 11 ON RP138550 & 0 BUP6971
 THIS PLAN IS COPY PROTECTED BY 360 CIVIL CONSULTING PTY. LTD.
                                                                                                                                            Datum:   A.H.D.          Size:       A3                    TITLE: PAVEMENT AND JOINTING DETAILS PLAN
                                                                                                                                                                                                                                                                                     07 of 12

Page 15

                                                                                                                                                                         LEGEND
                                                                                                                                                                                                             PROPOSED BUILDINGS
                                                                                                                                                                                                                                                                             SEWER RETICULATION NOTES
                                                                                                                                                                                                                                                                             GENERAL NOTES
                                                                                                                                                                                                             PROPOSED DRIVEWAY                                               G1     ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH CURRENT SOUTH
                                                                                                                                                                                                                                                                                    EAST QUEENSLAND SEWERAGE CODE SPECIFICATIONS AND STANDARDS.
                                                                                                                                                                            D     D         D    D    D
                                                                                                                                                                                                             EXISTING STORMWATER                                             G2     UNLESS SPECIFIED OTHERWISE ALL MATERIALS AND WORK SHALL COMPLY WITH
                                                                                                                                                                                                             EXISTING SEWER MAIN                                                    THE RELEVANT AUSTRALIAN STANDARDS.
                                                                                                                                                                                                                                                                             G3     THE CONSTRUCTION OF THE SEWERAGE WORK SHOWN ON THIS DRAWING SHALL
                                                                                                                                                                                                             EXISTING WATERMAIN
                                                                                                                                                                                                                                                                                    BE SUPERVISED BY AN ENGINEER WHO HAS RPEQ REGISTRATION. SEWERAGE
                                                                                                                                                                                                             EXISTING ENERGEX - OVERHEAD                                            WORKS NOT COMPLYING WITH THIS REQUIREMENT WILL NOT BE PERMITTED TO
                                                                                                                                                                                                             EXISTING TELSTRA                                                       CONNECT INTO THE SEQ SERVICE PROVIDER SEWERAGE SYSTEM.
                                                                                                                                                                                                                                                                             G4     ALL WORK ASSOCIATED WITH LIVE SEWERS OR MAINTENANCE HOLES SHALL BE
                                                                                                                                                                                      wat                    PROPOSED WATER METERS
                                                                                                                                                                                                                                                                                    CARRIED OUT BY UNITYWATER AT THE DEVELOPER'S COST.
                               THE COCKLESHELL                                                                                                                                                               EXISTING HCB                                                    G5     ALL PIPES AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE
                                                                                                                                                                                                                                                                                    "ACCEPTED PRODUCTS AND MATERIALS" LIST.
                                                                                                                                                                                                                                                                             G6     EACH NEW ALLOTMENT SHALL BE SERVED BY A DN150 PVC PROPERTY
                                                                                                                                                                                                                                                                                    CONNECTION.
                                                                                                                                                                                                                                                                             G7     PROPERTY CONNECTIONS SHALL BE LOCATED WITHIN THE PROPERTY AS SHOWN
                                                                                                                                                                                                                                                                                    IN THE DRAWING.
                                                                                                                                                                                                                                                                             G8     PROPERTY CONNECTION BRANCHES SHALL EXTEND INTO THE PROPERTY A
                                                                                                                                                                                                                                                                                    MINIMUM OF 750MM. UNITY WATER REQUIRES MINIMUM EXTENSION OF 500MM
                                                                                                                                                                                                                                                                                    INTO PROPERTY.
                                                                                                                                                                                                                                                                             G9     WHERE PIPES ARE LAID IN FILL, THE FILLING SHALL BE CARRIED OUT IN LAYERS
                                                                                                                                                                                                                                                                                    NOT EXCEEDING 300MM (LOOSE) IN DEPTH AND SHALL BE COMPACTED UNTIL THE
                                                                                                                                                                                                                                                                                    COMPACTION IS NOT LESS THAN 95% OF THE MATERIALS MAXIMUM COMPACTION
                                                                                                                                                                                                                                                                                    WHEN TESTED IN ACCORDANCE WITH A.S/ 1289 (MODIFIED COMPACTION). TESTING
                                                                                                                                                                                                                                                                                    SHALL BE CARRIED OUT AFTER EACH ALTERNATE LAYER, IN ALL SUCH CASES
                                                                                                                                                                                                                                                                                    APPROVAL OF CONSTRUCTED SEWERS WILL NOT BE ISSUED BY THE SEQ SERVICE
      4x DN20 WATER METERS AS PER STD                                                                                                                                                                                                                                               PROVIDER UNLESS CERTIFICATES ARE PRODUCED CERTIFYING THAT THE
      DWGS SEQ-WAT 1108-2 & SEQ-WAT 1108-3
                                                                                                                                                                                                                                                                                    REQUIRED COMPACTION HAS BEEN ACHIEVED.
      BY UNITYWATER AT DEVELOPERS                                                                                                                               REMAIN.                                                                                                      G10    WHERE SEWERS HAVE A GRADE OF 1 IN 20 OR STEEPER, BULKHEADS SHALL BE
      EXPENSE. EXISTING WATER METERS TO BE                                                                                                                      SL: 1.90                                                                                                            CONSTRUCTED IN ACCORDANCE WITH THE SEQ SEWER CODE.
      RELOCATED AND EXISITNG ROAD                                                                                                                               IL: -0.39                                                                                                    G11    THE CONTRACTOR SHALL VERIFY THE LOCATION AND DEPTH OF EXISTING
      CONDUITS TO BE UTILISED FOR NEW
                                                                                                                                                                                                                                                                                    SERVICES WITH RELEVANT AUTHORITIES BEFORE COMMENCING WORKS.
      WATER METERS.
                                                                                                                                                                                                                                                                             G12    SEWERS SHALL BE DISUSED/ABANDONED IN ACCORDANCE WITH PROCEDURES




                                                                                                                                                                                                                                       SEWER MAIN
                                                                                                                                                                                                                                                                                    SET OUT IN THE SEQ SEWER CODE.
                                                                                                                                                                                                                                                                             G13    BENCH MARK AND LEVELS TO AHD.
                               wat               wat   wat   wat
                                                                            t
                                                                         wa
                                                                         t
                                                                         wa




                                                                                                                                                                                                                                                                             WATER RETICULATION NOTES




                                                                                                                                                                                                                            IL -0.21
                                                                                                                                                                                                                                                                             VEGETATION PROTECTION
                                                                                wat




                                                                                                                                                                                                                                                SL 1.93                      A.     TREES LOCATED ALONG THE FOOTPATH SHALL BE, TRANSPLANTED PRIOR TO CONSTRUCTION,
                                                                                               EXISTING WATER METERS TO BE                                                                                                                                                          OR REPLACE IF DESTROYED.
                                                                         wa




                                                                                                                                                                                                                                                    IL -0.07    SEWER MAIN
                                                                            t




                                                                                               RELOCATED                                                                                                                                                                     B.     WHEN WORKING WITHIN 4M OF TREES, RUBBER OR HARDWOOD GIRDLES SHALL BE
                                                                   wat




                                                                                                                                                                                                                            IL -0.20
                              wat                wat   wat   wat
                                                                                                                                                                                                                                                                                    CONSTRUCTED WITH 1.8M BATTENS CLOSELY SPACED AND ARRANGED VERTICALLY FROM
                                                                                                                                                                                                                                                                                    GROUND LEVEL. GIRDLES SHALL BE STRAPPED TO TREES PRIOR TO CONSTRUCTION AND
                                                                                                                                                                                                                                                                                    REMAIN UNTIL COMPLETION.
                                                                                                                                                                                                                                                                             C.     TREE ROOTS SHALL BE TUNNELLED UNDER, RATHER THAN SEVERED. IF ROOTS ARE SEVERED
                                                                                                                                                                                                                                                                                    THE DAMAGED AREA SHALL BE TREATED WITH A SUITABLE FUNGICIDE. CONTACT RELEVANT
                                                                                                                                                                                                                                                                                    ARBORIST FOR FURTHER ADVICE.
                                                                                                                                                                                                                                                                             D.     ANY TREE LOPPING REQUIRED SHOULD BE UNDERTAKEN BY AN APPROVED ARBORIST.

                                                                                                                                                                                                                                                                             SOIL
                                                                                                                                                                REMAIN.                                                                                                      A.     TOPSOIL AND SUBSOIL SHALL BE STOCKPILED SEPARATELY.
                                                                                                                                                                SL: 1.93                                                                                                     B.     CARE SHALL BE TAKEN TO PREVENT SEDIMENT FROM ENTERING THE STORMWATER SYSTEM.
                                                                                                                                                                IL: -0.20                                                                                                           THIS MAY INVOLVE PLACING APPROPRIATE SEDIMENT CONTROLS AROUND STOCKPILES.




                                                                                                                                                                                                                                       SEWER MAIN
                                                                                                                                                                                                                                                                             REHABILITATION
                                                                                                                                                                                                                                                                             A.     PREDISTURBANCE SOIL PROFILES AND COMPACTION LEVELS SHALL BE REINSTATED.
                                                                                                                                                                                                                                                                             B.     PREDISTURBANCE VEGETATION PATTERNS SHALL BE RESTORED.
                                                                                                                                                                                                                                                                             GENERAL NOTES
                                                                                                                                                                                                                                                                             G1     ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH CURRENT SOUTH EAST
                                                                                                                                                                                                                                                                                    QUEENSLAND WATER SUPPLY CODE SPECIFICATIONS AND STANDARDS
                                                                                                                                                                                                                                                                             G2     UNLESS SPECIFIED OTHERWISE ALL MATERIALS AND WORK SHALL COMPLY WITH THE
                                                                                                                               UP                    UP                                                                                                                             RELEVANT AUSTRALIAN STANDARDS.
                                                                                                                                                                                                                                                                             G3     ADOPT LIP OF KERB OR SHOULDER OF ROAD AS PERMANENT LEVEL.
                                                                                                                                                                                                                                                                             G4     COVER ON MAINS FROM PERMANENT LEVEL TO BE AS SHOWN IN SEQ-WAT-1200-2
                                                                                                                                                                                                                                                                             G5     CONDUITS TO BE INSTALLED IN ACCORDANCE WITH THE STANDARD DRAWINGS.
                                                                                                                                                                                                                                                                             G6     A WATER METER SUPPLIED AT THE DEVELOPERS COST, IS TO BE INSTALLED AT THE SERVICE
                                                                                                                                                                                                                                                                                    POINT OF EACH LOT IN ACCORDANCE WITH THE SEQ CODE.
                                                                                                                                                                                                                                                                             G7     ALL MATERIALS USED IN THE WORKS SHALL COMPLY WITH THE SEQ-SP'S ACCEPTED PRODUCTS
                                                                                                                                                                                                                                                                                    AND MATERIALS LIST OR BE APPROPRIATELY SHOWN, LISTED AND DEFINED IN THE
                                                                                                                                                                                                                                                                                    ENGINEERING SUBMISSION SO THAT THE ALTERNATIVE PRODUCT OR MATERIAL CAN BE
                                                                                                                                                                                                                                                                                    ASSESSED AND IF APPROPRIATE SEQ-SP.
                                                                                                                                                                                                                                                                             G8     ALL CONCRETE FOOTPATHS TO BE CLEAR OF WATER MAINS.
                                                                                                                                                                                                                                                                             G9     TEST/CHLORINATION POINTS TO BE INSTALLED IN ACCORDANCE WITH STANDARD DRAWING
                                                                                      ALL ENVIRONMENTAL PROTECTION MEASURES SHOULD                                                                                                                                                  NO.SEQ-WAT-1410-1
                                                                                      BE IMPLEMENTED PRIOR TO ANY CONSTRUCTION WORK,                                                                                                                                         G10    THE CONSTRUCTION OF THE WATER RETICULATION WORK SHOWN ON THIS DRAWING MUST BE
                                                                                      INCLUDING CLEARING COMMENCING.                                                                                                                                                                SUPERVISED BY AN ENGINEER WHO HAS RPEQ REGISTRATION. WORKS NOT COMPLYING WITH
                                                                                                                                       RP Description                                                                                                                        G11
                                                                                                                                                                                                                                                                                    THIS REQUIREMENT WILL NOT BE PERMITTED TO CONNECT TO THE RETICULATION SYSTEM.
                                                                                                                                                                                                                                                                                    ALL WATERMIAINS SHALL HAVE APPROVED DETECTABLE MARKER TAPE LAID ON TOP OF THE
  CAUTION -                                                                                                                                                                                                                                                                           BEDDING.
  EXISTING SERVICES THE CONTRACTOR IS TO DETERMINE THE EXACT                                                                           Lot 11 RP138550 & Lot 0 BUP6971
  LOCATION OF ALL EXISTING SERVICES IN THE VICINITY OF THE                                                                             30-32 Cockleshell, Noosaville
  PROPOSED WORKS PRIOR TO THE START OF ANY CONSTRUCTION.
  THE COST OF ANY RECTIFICATION WORKS DUE TO DAMAGE TO
  EXISTING SERVICES SHALL BE BORNE BY THE CONTRACTOR.


    360 CIVIL CONSULTING PTY LTD                                                         No    Date                        Amendment
                                                                                                                                           Design:   J.A.G                       FOR APPROVAL                                CLIENT:                           JOHNSON COLES, JOHNSON, RANDALL & HUSSAIN                                                      JOB NUMBER
                                                                                         A    08-03-18 CHANGES AS PER COUNCIL RFI
                        ABN: 13 609 593 339                                                                                                Drawn:    J.A.G                                                                   PROJECT:                          PROPOSED DUPLEX DEVELOPMENT
BEATRICE GIBBERD RPEQ 14557 - DIRECTOR AND PRINCIPAL ENGINEER
                                                                                                                                                                                                                                                                                                                                                               2017115
           23 OOGAR STREET, MAROOCHYDORE. QLD 4558                                                                                         Date:     15/07/17
                                                                                                                                                                      BEATRICE GIBBERD RPEQ 14557                            AT:                      30-32 COCKLESHELL, NOOSAVILLE
                                                                                                                                                                                                                                                                                                                                                              DRAWING No:
   Mobile: 0403 862 009  Email: [email protected]                                                                         Checked: B.G.                    DATE:               15/07/2017                                            LOT 11 ON RP138550 & 0 BUP6971
 THIS PLAN IS COPY PROTECTED BY 360 CIVIL CONSULTING PTY. LTD.
                                                                                                                                            Datum:   A.H.D.                     Size:                A3                      TITLE: SEWER AND WATER CONNECTION PLAN
                                                                                                                                                                                                                                                                                                                                                               08 of 12

Page 16

                                                                                                                                                                                                                                                 LEGEND
                                                                                                                                                                                                                                                                      PROPOSED CUT


                                                                                                                                                                                                                                                                      PROPOSED FILL

                                                                                                                                                                                                                                                  D   D   D   D   D
                                                                                                                                                                                                                                                                      EXISTING STORMWATER
                                                                                                                                                                                                                                                                      EXISTING SEWER MAIN
                                                                                                                                                                                                                                                                      EXISTING WATERMAIN
                                                                                                                                                                                                                                                                      EXISTING ENERGEX - UNDERGROUND
                                                           X                  X                  X                  X       X             X                  X              X                X                                                                X       EXISTING TELSTRA
                                                                                                                                                                                                                                                                      SEDIMENT FENCE




                                                                                                                                                                                                  X
                                                      X
           TURF STRIPS BEHIND KERB AND
                                                                     EFFECTIVELY STABILISE SITE AS




                                                                                                                                                                                                  X
           CHANNEL


                                                     X
                                                                     SOON AS PRACTICABLE AFTER
                                                                     COMPLETION OF CIVIL AND BUILDING
                                                                     WORKS




                                                                                                                                                                                                  X
           TEMPORARY STABILISED SITE
           ACCESS                                                                                                                                                                                                 SEDIMENT FENCE




                                                                                                                                                                                                  X
                                                                                                                                                                                                  X
                                                                                                                                                                                                  X
                                                                                                                                                                                                  X
                                                      X




                                                                                                                                                                                                  X
                                                                                                               UP                                           UP
                                                      X




                                                               X                   X                    X               X       X             X                   X             X                 X



                                                                                                                                CAUTION -
                                                                                                                                EXISTING SERVICES THE CONTRACTOR IS TO DETERMINE THE EXACT
                                                                                                                                LOCATION OF ALL EXISTING SERVICES IN THE VICINITY OF THE
                                                                                                                                PROPOSED WORKS PRIOR TO THE START OF ANY CONSTRUCTION.
                                                                                                                                THE COST OF ANY RECTIFICATION WORKS DUE TO DAMAGE TO
                                                                                                                                EXISTING SERVICES SHALL BE BORNE BY THE CONTRACTOR.



    360 CIVIL CONSULTING PTY LTD                                      No    Date                            Amendment
                                                                                                                                                  Design:   J.A.G             FOR APPROVAL            CLIENT:    JOHNSON COLES, JOHNSON, RANDALL & HUSSAIN                               JOB NUMBER
                                                                      A    08-03-18 CHANGES AS PER COUNCIL RFI
                        ABN: 13 609 593 339                                                                                                       Drawn:    J.A.G                                     PROJECT:   PROPOSED DUPLEX DEVELOPMENT
BEATRICE GIBBERD RPEQ 14557 - DIRECTOR AND PRINCIPAL ENGINEER
                                                                                                                                                                                                                                                                                            2017115
           23 OOGAR STREET, MAROOCHYDORE. QLD 4558                                                                                                Date:     04/11/17
                                                                                                                                                                        BEATRICE GIBBERD RPEQ 14557   AT:   30-32 COCKLESHELL, NOOSAVILLE
                                                                                                                                                                                                                                                                                         DRAWING No:
   Mobile: 0403 862 009  Email: [email protected]                                                                                Checked: B.G.            DATE:     04/11/2017             LOT 11 ON RP138550 & 0 BUP6971
 THIS PLAN IS COPY PROTECTED BY 360 CIVIL CONSULTING PTY. LTD.
                                                                                                                                                  Datum:    A.H.D.           Size:      A3            TITLE: EROSION AND SEDIMENT PLAN
                                                                                                                                                                                                                                                                                            09 of 12

Page 17

                                                                                                                                                                                                                                                                                                                                                                                     1. GENERAL
                                                                                                                                                                                                                                                                                                                                                                                        (A) TEMPORARY DRAINAGE CONTROL. FLOW SHOULD BE DIVERTED AROUND
                                                                                                                                                                                                                                                                                                                                                                                             THE WORK SITE WHERE POSSIBLE.
                                                                                                                                                                                                                                                          ETRES                                                                                                                         (B) ALL DRAINAGE, EROSION AND SEDIMENT CONTROLS TO BE INSTALLED IN
                                                           AT MAX. 2.5 M CENTRES
                                                                                                       SELF-SUPPORTING
                                                                                                                                                                                                                                        ID     TH 3 M
                                                                                                       GEOTEXTILE                                                                                                                 MIN. W                                                                                                                                                     ACCODANCE WITH I E AUST. SOIL EROSION AND SEDIMENT CONTROL
                                                                                                                                                                                                                                                                                                                                                                                             MANUAL, AS DETAILED ON THIS PLAN, OR AS REQUIRED FOR COMPLIANCE
                                                                                                                                                                                                                                                                                                                                                                                             WITH THE REQUIREMENTS OF THE ENVIRONMENTALMANAGEMENT PLAN /
                                                                                                                                                                                                                                                                                                                                                                                             EROSION & SEDIMENT CONTROL PLAN.
                                                                                                                                                                                                                                                                                                                                                                                        (C) ALL DRAINAGE, EROSION AND SEDIMENT CONTROLS TO BE OPERATIONAL
                                                        500 MM TO 600 MM                              DIRECTION OF                                                CONSTRUCTION SITE                                                         MIN.
                                                                                                                                                                                                                                                     LENG                                                                                                                                    BEFORE COMMENCING UP-SLOPE EARTHWORKS AND SHALL REMAIN IN
                                                                                                      FLOW                                                                                                                                                  TH 15                                                                                                                            PLACE UNTIL PERMANENT WORKS ARE COMPLETE AND CATCHMENT
                                                                                                                                                                                                                                                                    METR                                                                                                                     VEGETATION IS ESTABLISHED (60% GRASS COVER MINIMUM)
                                                                                                                                                                                                                                                                        ES
                                                                                                                                                                                                                                                                                                                                                                                        (D) THE CONTRACTOR IS RESPONSIBLE FOR ENSURING SEDIMENT AND EROSION
                                                                                                                                                                                                                                                                                                                                                                                             CONTROL DEVICES ARE INSPECTED & MAINTAINED AS FOLLOWS
                                                                                                                                                                                      200 MM MIN.                                                                                                                                                                                                (1) DURING CONSTRUCTION & DEFECT LIABILITY PERIOD
                                                          600 MM MIN.                                                                                                                                                                                                                                                                                                                                (i) WEEKLY DURING DRY WEATHER
                                                                                                  ON SOIL, 150 MM X 100 MM
                                                                                                                                                                                                                                                                                                                   DARY                                                                              (ii) PRIOR TO PREDICTED STORM EVENTS
                                                                                                  TRENCH WITH COMPACTED                                                                                                                                                                                     BOUN
                                                                                                                                                                                                                                                                                                     ERTY                                                                                            (iii) TWICE DAILY DURING PROLONGEDE RAIN
                                                                                                  BACKFILL AND ON ROCK, SET                                                                                                                           300 MM MIN.                            PROP
                                                                                                  INTO SURFACE CONCRETE                                                                                                                                                                                                                                                                              (iv) DURING AND AFTER MAJOR STORM EVENTS
                                                                                                                                                                                                                                                                                                                                                                                        (E) ALL DISTURBED LAND MUST BE TREATED TO PREVENT RAIN DROP IMPACT
                                                                                                                                                                                                                                                                                                                                                                                             EROSION BY THE ESTABLISHMENT OF 60% EFFECTIVE GROUND COVER
                                                                              SECTION DETAIL                                                                                                                                                                                                                                                                                                 WITHIN 28 DAYS OF FINAL EARTHWORKS TRIM.
                                                                                                                                                                                                                                                                                                                                                                                        (F) IN AREAS WHERE RUNOFF TURBIDITY IS TO BE CONTROLLED, EXPOSED
                                   DISTURBED AREA                                                                                                                                                                                                                                                                                                                                           SURFACES TO BE EITHER MULCHED, COVERED WITH EROSION CONTROL
                                                                                                                                            RUNOFF DIRECTED TO                                                                                                                                                                                                                              BLANKETS OR TURFED IF EARTHWORKS ARE EXPECTED TO BE DELAYED
                                                                                                                                            SEDIMENT TRAP/FENCE                                                                                                                                                                                                                             FOR MORE THAN 14 DAYS.
                                                              DIRECTION OF                                                                                                                                                                                                                                                                                                              (G) STRAW BALE SEDIMENT TRAPS ARE A SECONDARY OPTION WHICH
                                                                 FLOW                                                                                                                                                                                                                                                                                                                       GENERALLY SHOULD NOT BE USED IF OTHER OPTIONS ARE AVAILABLE.
                                                                                                                                                                                              DGB 20 ROADBASE OR
                                                                                               1.5 M STAR PICKETS
                                                                                                                                                                                              30 MM AGGREGATE                                                                                                                                                                         2. SEDIMENT CONTROL FENCE
                                                                                               AT MAX. 2.5 M CENTRES
                                                                                                                                                                                                                                                                                                                                                                                         (A) NOT TO BE LOCATED IN AREAS OF CONCENTRATED FLOW.
                                                                                                                                                                                                                                                                                                                                                                                         (B) NORMALLY LOCATED ALONG THE CONTOUR WITH A MAXIMUM
                                                                                                                                                                                                                                                                                EXISTING ROADWAY                                                                                              CATCHMENT AREA 0.6 HA PER 100M LENGTH OF FENCE.
                                                                                                                                                                                                            GEOTEXTILE FABRIC DESIGNED TO                                                                                                                                                (C) WOVEN FABRICS ARE PREFERRED, NON-WOVEN FABRICS MAY BE USED
                                                                                                                                                                                                            PREVENT INTERMIXING OF SUBGRADE                                                                                                                                                   ON SMALL WORK SITES, I.E. OPERATIONAL PERIOD LESS THAN 6
                                                                                                                                                                                                            AND BASE MATERIALS AND TO MAINTAIN
                                                                                                                                                                                                                                                                                                                                                                                              MONTHS OR ON SITES WHERE SIGNIFICANT SEDIMENT RUNOFF IS NOT
                                                                                                                                                                                                            GOOD PROPERTIES OF THE SUB-BASE LAYERS.
                                                                                                                                                                                                                                                                                                                                                                                              EXPECTED.
                                                                                                                                                                                                            GEOFABRIC MAY BE A WOVEN OR NEEDLE-PUNCHED
                                                                                                                                                                                                                                                                                                                                                                                         (D) WHERE FENCES NEED TO BE LOCATED ACROSS THE CONTOUR -
                                                                                                                                                                                                                                                                                                                                                                                               REFER IPEAWQ STANDARD DRAWING D-0040 FOR DETAILS.
                                                                                                                                                                                                            PRODUCT WITH A MINIMUM CBR
                                                                                                                                                                                                                                                                                                                                                                                         (E) FENCES ARE REQUIRED 2m MIN FROM TOE OF CUT OR FILL BATTERS,
                                                                                                                                                                                                            BURST STRENGTH (AS3706.4-90) OF 2500 N
                       UNDISTURBED AREA                                                                                                                                                                                                                                                                                                                                                        WHERE NOT PRACTICAL ONE FENCE CAN BE AT THE TOE WITH A SECOND
                                                                                                                                                                                                                                                                                                                                                                                               FENCE 1M MIN AWAY. FENCE SHOULD NOT BE LOCATED PARALLEL WITH
                                                                                                                                                                                                                                                                                                                                                                                               TOE IF CONCENTRATION OF FLOW WILL OCCUR BEHIND THE FENCE.
                                                                                                                                                                                                                                                                                                                                                                                      3. TEMP CONSTRUCTION ENTRY/EXIT SEDIMENT TRAP.
                                                                                                                                                                                                                                                                                                                                                                                            (A) ADJACENT STORMWATER RUNOFF TO BE DIVERTED AWAY FROM ENTRY/EXIT.
                                                                                                                                                                                                                                                                                                                                                                                            (B) WHEEL - WASH OR SPRAY UNIT MAY BE REQUIRED DURING WET WEATHER.
                                                                                                                                                                                              N.T.S.                                                                                                                                                                                  4. SAFETY ISSUES MUST BE CONSIDERED AT ALL TIMES, INCORPORATE
                                                                                                                                                                                             CONSTRUCTION NOTES                                                                                                                                                                            TRAFFIC CONTROL DEVICES TO THE SATISFACTION OF THE
                                                                        20 M MAX.
                                                                                       SWMP/ESCP)                                                                                            1. STRIP THE TOPSOIL, LEVEL THE SITE AND COMPACT THE SUBGRADE.                                                                                                                                SUPERINTENDENT.
                                                                          OTHERWISE ON
                                                           (UNLESS STATED                                                                                                                    2. COVER THE AREA WITH NEEDLE-PUNCHED GEOTEXTILE.                                                                                                                                                         5.
                                                                                                                                                                                                                                                                                                                                                                                           IT IS THE CONTRACTOR'S   RESPONSIBILITY TO ENSURE THAT ALL SEDIMENT
                                                                                                                                                                                             3. CONSTRUCT A 200 MM THICK PAD OVER THE GEOTEXTILE USING ROAD BASE                                                                                                                           AND EROSION CONTROL MEASURES HAVE BEEN ADDRESSED AS STIPULATED
                                                                                   FLOW                                                                                                      OR 30 MM AGGREGATE.                                                                                                                                                                           IN THE ENVIRONMENTAL MANAGEMENT PLAN / EROSION & SEDIMENT CONTROL
                                                                                                                                                                                             4. ENSURE THE STRUCTURE IS AT LEAST 15 METRES LONG OR TO BUILDING                                                                                                                             PLAN. ADDITIONAL CONTROL DEVICES MAY BE REQUIRED DURING CONSTRUCTION
                                                                                                                                                                                             ALIGNMENT AND AT LEAST 3 METRES WIDE.                                                                                                                                                         PHASE, AS DIRECTED ON SITE BY THE SUPERINTENDANT.
                                                                                                                                                                                             5. WHERE A SEDIMENT FENCE JOINS ONTO THE STABILISED ACCESS,                                                                                                                                   TEMPORARY   6. STOCKPILES TO HAVE 1:6 SIDE BATTERS (MAXIMUM) AND BE
                                                                                                                                                                                             CONSTRUCT A HUMP IN THE STABILISED ACCESS TO DIVERT WATER TO THE                                                                                                                              SHAPED TO ENSURE RUN-OFF IS TREATED AND MANAGED TO THE
                                                                                                                                                                                             SEDIMENT FENCE                                                                                                                                                                                SATISFACTION OF THE SUPERINTENDANT. ALL EXPOSED STOCKPILE
                                                                                                                                                                                                                                                                                                                                                                                           SURFACES TO BE GRASS SEEDED. SEDIMENT FENCES AND CUT-OFF
                                                                                                                                                                                                                                                                                                                                                                                           DRAINS MAY BE REQUIRED, AT THE DISCRETION OF THE SUPERINTENDANT.
                      MIN. 1.5 M
                                                                                                                                                                                                                                                                                                                                                                                      7. SEDIMENT AND EROSION CONTROL DEVICES (OTHER THAN THOSE ALREADY
                                                    STAR PICKETS AT MAXIMUM                            PLAN                                                                                                                                                                                                                                                                                 SHOWN) ARE TO BE INSTALLED WHERE NECESSARY AND AS DIRECTED BY
                                                    2.5 M SPACINGS                                                                                                                                                                                                                                                                                                                          SUPERINTENDENT
                                                                                                                                                                                                                                                                                                                                                                                      8. SEDIMENT AND EROSION CONTROL DEVICES ON THIS PLAN ARE INDICATIVE
                                                                                                                                                                                                                                                                                                                                                                                            ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT THE
                     N.T.S.
                                                                                                                                                                                                                                                                                                                                                                                            INTENTS OF THIS PLAN AND ENVIRONMENTAL MANAGEMENT PLAN ARE COMPLIED
                     CONSTRUCTION NOTES                                                                                                                                                                                                                                                                                                                                                     WITH.

                     1. CONSTRUCT SEDIMENT FENCES AS CLOSE AS POSSIBLE TO BEING PARALLEL TO THE CONTOURS OF THE                                                                                                                      RET
                     SITE, BUT WITH SMALL RETURNS AS SHOWN IN THE DRAWING TO LIMIT THE CATCHMENT AREA OF ANY ONE                                                                                                                   5 ME URN T
                     SECTION. THE CATCHMENT AREA SHOULD BE SMALL ENOUGH TO LIMIT WATER FLOW IF CONCENTRATED AT                                                                                                                          TRE URF                                                             CONSTRUCTION NOTES
                     ONE POINT TO 50 LITRES PER SECOND IN THE DESIGN STORM EVENT, USUALLY THE 10-YEAR EVENT.                                                                                                                                 S TO STR
                                                                                                                                                                                                                                                 PRE IPS E                                                  1. INSTALL A 2 x 400mm MINIMUM WIDE ROLL OF TURF ON THE
                     2. CUT A 150-MM DEEP TRENCH ALONG THE UPSLOPE LINE OF THE FENCE FOR THE BOTTOM OF THE FABRIC                                                                                                                                   VEN VER
                     TO BE ENTRENCHED.                                                                                                                                                                                                                 T SC Y                                               VERGE NEXT TO THE KERB AND AT THE SAME LEVEL AS THE TOP
                                                                                                                                                                                                                                                           OUR                                              OF THE KERB.
                     3. DRIVE 1.5 METRE LONG STAR PICKETS INTO GROUND AT 2.5 METRE INTERVALS (MAX) AT THE DOWNSLOPE
                                                                                                                                                                                                                                                                                                            2. LAY 1.4 METRE LONG TURF STRIPS NORMAL TO THE KERB EVERY
                     EDGE OF THE TRENCH. ENSURE ANY STAR PICKETS ARE FITTED WITH SAFETY CAPS.                                                                                                                                             E TR E
                                                                                                                                                                                                                                      1 M                                                                   5 METRES.
                     4. FIX SELF-SUPPORTING GEOTEXTILE TO THE UPSLOPE SIDE OF THE POSTS ENSURING IT GOES TO THE
                     BASE OF THE TRENCH. FIX THE GEOTEXTILE WITH WIRE TIES OR AS RECOMMENDED BY THE
                     MANUFACTURER. ONLY USE GEOTEXTILE SPECIFICALLY PRODUCED FOR SEDIMENT FENCING. THE USE OF
                     SHADE CLOTH FOR THIS PURPOSE IS NOT SATISFACTORY.
                     5. JOIN SECTIONS OF FABRIC AT A SUPPORT POST WITH A 150-MM OVERLAP.
                     6. BACKFILL THE TRENCH OVER THE BASE OF THE FABRIC AND COMPACT IT THOROUGHLY OVER THE
                                                                                                                                                                                                                                                                                 M   MIN.
                     GEOTEXTILE.                                                                                                                                                                                             TUR
                                                                                                                                                                                                                                F                                          800 M

                                                                                                                                                                                                            KER
                                                                                                                                                                                                                B


                                                                                                                                                                                                    GUT
                                                                                                                                                                                                        T   ER

                                                                                                                                                                                          ROA
                                                                                                                                                                                                DW
                                                                                                                                                                                                       AY




                                                                                                                                                                                       N.T.S.




    360 CIVIL CONSULTING PTY LTD                                                                              No       Date                          Amendment
                                                                                                                                                                                                                                                      Design:        J.A.G                            FOR APPROVAL                              CLIENT:        JOHNSON COLES, JOHNSON, RANDALL & HUSSAIN                                                       JOB NUMBER
                                                                                                               A     08-03-18 CHANGES AS PER COUNCIL RFI
                        ABN: 13 609 593 339                                                                                                                                                                                                           Drawn:         J.A.G                                                                      PROJECT:       PROPOSED DUPLEX DEVELOPMENT
BEATRICE GIBBERD RPEQ 14557 - DIRECTOR AND PRINCIPAL ENGINEER
                                                                                                                                                                                                                                                                                                                                                                                                                                                                  2017115
           23 OOGAR STREET, MAROOCHYDORE. QLD 4558                                                                                                                                                                                                    Date:          04/11/17
                                                                                                                                                                                                                                                                                            BEATRICE GIBBERD RPEQ 14557                         AT:      30-32 COCKLESHELL. NOOSAVILLE
                                                                                                                                                                                                                                                                                                                                                                                                                                                               DRAWING No:
   Mobile: 0403 862 009  Email: [email protected]                                                                                                                                                                                    Checked: B.G.                                DATE:       04/11/2017                                LOT 11 ON RP138550 & 0 BUP6971
 THIS PLAN IS COPY PROTECTED BY 360 CIVIL CONSULTING PTY. LTD.
                                                                                                                                                                                                                                                       Datum:        A.H.D.                         Size:           A3                          TITLE: EROSION & SEDIMENT CONTROL DETAILS PLAN
                                                                                                                                                                                                                                                                                                                                                                                                                                                                  10 of 12

Page 18

                                                                                                                                                                                                                                                                                                    I.P.17.073, 2.544
                                                                                                                                                                                     I.P.9.848, 2.111
                                                                                                                                           PROPERTY BDY
                                                                                                                                           I.P.5.692, 1.909
                                                                                                           I.P.3.014, 1.775
                                                                               I.P.1.500, 1.737
                 GRADE                                               12.500%                      2.500%                      5.000%                          4.860%                                                                              6.000%                                                                                          0.500%


                 DATUM R.L.0.0



                 CUT(-)/FILL(+)



                 DESIGN SURFACE

                 LEVELS



                 NATURAL SURFACE

                 LEVELS




                 CHAINAGE




                                                                                                                                                                                                          LONG SECTION-DRIVEWAY 1
                                                                                                                                                                                                          SCALE 1:100




                                                                                                                                                                                                                                                  I.P.3.866, 1.800
                                                                                                                                                                                                                I.P.1.493, 1.741
                                                                                                                                                                                12.500%                                                2.500%                                             4.846%
                                                                                                           GRADE

                                                                                                            DATUM R.L.0.0



                                                                                                            CUT(-)/FILL(+)



                                                                                                            DESIGN SURFACE

                                                                                                            LEVELS


                                                                                                            NATURAL SURFACE

                                                                                                            LEVELS




                                                                                                            CHAINAGE




                                                                                                                                                                       LONG SECTION-DRIVEWAY 2
                                                                                                                                                                       SCALE 1:100



    360 CIVIL CONSULTING PTY LTD                                      No   Date                                                Amendment
                                                                                                                                                                                                        Design:                    J.A.G                              FOR APPROVAL                 CLIENT:                JOHNSON COLES, JOHNSON, RANDALL & HUSSAIN   JOB NUMBER
                        ABN: 13 609 593 339                                                                                                                                                             Drawn:                     J.A.G                                                           PROJECT:               PROPOSED DUPLEX DEVELOPMENT
BEATRICE GIBBERD RPEQ 14557 - DIRECTOR AND PRINCIPAL ENGINEER
                                                                                                                                                                                                                                                                                                                                                                          2017115
           23 OOGAR STREET, MAROOCHYDORE. QLD 4558                                                                                                                                                      Date:                      04/11//17
                                                                                                                                                                                                                                                BEATRICE GIBBERD RPEQ 14557                        AT:                  30-32 COCKLESHELL, NOOSAVILLE
                                                                                                                                                                                                                                                                                                                                                                      DRAWING No:
   Mobile: 0403 862 009  Email: [email protected]                                                                                                                                      Checked: B.G.                                 DATE:                  04/11/2017                                 LOT 11 ON RP138550 & 0 BUP6971
 THIS PLAN IS COPY PROTECTED BY 360 CIVIL CONSULTING PTY. LTD.
                                                                                                                                                                                                        Datum:                     A.H.D.                            Size:      A3                 TITLE: DRIVEWAY LONGITUDINAL SECTIONS
                                                                                                                                                                                                                                                                                                                                                                       11 of 12

Page 19

                                                                                                                        Centreline Data                                                                                                      Centreline Data

                                                                                                                        X = 371.544                                                                                                          X = 352.879
       Centreline Data                                                                                                                                                                                                                       Y = 366.340
                                                                                                                        Y = 366.510
       X = 349.810                                                                                                                                                                                                                           Z = 2.097
                                                                                                                        Z = 2.600
       Y = 369.085
       Z = 1.909                                                                                                        DATUM RL 1.000                                                                                                       DATUM RL 1.000




                                                                                                                                                                                                                                                                        2.097




                                                                                                                                                                                                                                                                                         2.097




                                                                                                                                                                                                                                                                                                        2.097
                                                                                                                                          2.600




                                                                                                                                                                        2.600




                                                                                                                                                                                                2.600
       DATUM RL 1.000                                                                                                   DESIGN                                                                                                               DESIGN




                                                     1.909




                                                                           1.909


                                                                                   1.909
       DESIGN




                                                                                                                                                                                                                                                                        2.032




                                                                                                                                                                                                                                                                                         2.266




                                                                                                                                                                                                                                                                                                        2.213
                                                                                                                                                                        1.916




                                                                                                                                                                                                1.946
                                                                                                                        SURVEY                                                                                                               SURVEY




                                                     1.798




                                                                           1.874


                                                                                   1.909
       SURVEY




                                                                                                                                                                                                                                                                        -2.000




                                                                                                                                                                                                                                                                                         0.000




                                                                                                                                                                                                                                                                                                        2.000
                                                                                                                                          -2.000




                                                                                                                                                                        0.000




                                                                                                                                                                                                2.000
                                                                                                                        OFFSET                                                                                                               OFFSET




                                                     -2.109




                                                                           0.000


                                                                                   0.927
       OFFSET
                                                                                                                                                                 CHAINAGE 28.311                                                                                                   CHAINAGE 10

                                                                                                                                                                                                                                             Centreline Data
                                                              CHAINAGE 5.692
                                                                                                                                                                                                                                             X = 347.481
                                                                                                                        Centreline Data
       Centreline Data                                                                                                                                                                                                                       Y = 361.549
                                                                                                                        X = 360.233
       X = 347.692                                                                                                                                                                                                                           Z = 1.773
                                                                                                                        Y = 366.516
       Y = 370.746
                                                                                                                        Z = 2.540                                                                                                            DATUM RL 1.000
       Z = 1.774




                                                                                                                                                                                                                                                                         1.773




                                                                                                                                                                                                                                                                                       1.773




                                                                                                                                                                                                                                                                                                         1.773
                                                                                                                        DATUM RL 1.000                                                                                                       DESIGN
       DATUM RL 1.000




                                                                                                                                                     2.540




                                                                                                                                                                                 2.540




                                                                                                                                                                                                             2.540
                                                                                                                        DESIGN
                                            1.774




                                                                   1.774




                                                                                                   1.774
       DESIGN




                                                                                                                                                                                                                                                                         1.869




                                                                                                                                                                                                                                                                                       1.841




                                                                                                                                                                                                                                                                                                         1.852
                                                                                                                                                                                                                                             SURVEY




                                                                                                                                                                                 1.977




                                                                                                                                                                                                             2.016
                                                                                                                        SURVEY
                                            1.782




                                                                   1.830




                                                                                                   1.759
       SURVEY                                                                                                                                                                                                                                OFFSET




                                                                                                                                                                                                                                                                         -1.852




                                                                                                                                                                                                                                                                                       0.000




                                                                                                                                                                                                                                                                                                         2.158
                                                                                                                        OFFSET




                                                                                                                                                     -2.000




                                                                                                                                                                                 0.000




                                                                                                                                                                                                             2.608
                                            -2.003




                                                                   0.000




                                                                                                   2.501
       OFFSET
                                                                                                                                                                                                                                                                                   CHAINAGE 2.782
                                                                                                                                                                                CHAINAGE 17
                                                                  CHAINAGE 3                                            Centreline Data                                                                                                      Centreline Data
       Centreline Data
                                                                                                                        X = 353.233                                                                                                          X = 346.192
       X = 346.203
                                                                                                                        Y = 366.519                                                                                                          Y = 361.549
       Y = 370.778
                                                                                                                        Z = 2.120                                                                                                            Z = 1.741
       Z = 1.737

                                                                                                                        DATUM RL 1.000                                                                                                       DATUM RL 1.000
       DATUM RL 1.000




                                                                                                                                                                                                                                                                        1.741




                                                                                                                                                                                                                                                                                       1.741




                                                                                                                                                                                                                                                                                                         1.741
                                                                                                                                            2.120




                                                                                                                                                                                     2.120




                                                                                                                                                                                                                     2.120
                                                                                                                        DESIGN                                                                                                               DESIGN
                                           1.737




                                                                  1.737




                                                                                           1.737




       DESIGN




                                                                                                                                                                                                                                                                        1.767




                                                                                                                                                                                                                                                                                       1.768




                                                                                                                                                                                                                                                                                                         1.776
                                                                                                                                            1.912




                                                                                                                                                                                     2.298




                                                                                                                                                                                                                     2.107
                                                                                                                        SURVEY                                                                                                               SURVEY
                                           1.778




                                                                  1.763




                                                                                           1.762




       SURVEY




                                                                                                                                                                                                                                                                        -1.875
                                                                                                                                            -2.693




                                                                                                                                                                                                                                                                                       0.000




                                                                                                                                                                                                                                                                                                         2.154
                                                                                                                                                                                     0.000




                                                                                                                                                                                                                     2.739
                                                                                                                        OFFSET                                                                                                               OFFSET
                                           -2.000




                                                                  0.000




                                                                                           2.000




       OFFSET

                                                                                                                                                                                                                                                                                  CHAINAGE 1.493
       Centreline Data                                        CHAINAGE 1.5                                                                                                      CHAINAGE 10
                                                                                                                        Centreline Data                                                                                                      Centreline Data
       X = 344.703                                                                                                      X = 353.081                                                                                                          X = 344.699
       Y = 370.778                                                                                                      Y = 366.519                                                                                                          Y = 361.549
       Z = 1.549                                                                                                        Z = 2.111                                                                                                            Z = 1.554                            0%               0%

       DATUM RL 1.000                                                                                                   DATUM RL 1.000                                                                                                       DATUM RL 1.000
                                           1.549




                                                                  1.549




                                                                                           1.549




                                                                                                                                                                                                                                                                        1.554




                                                                                                                                                                                                                                                                                       1.554




                                                                                                                                                                                                                                                                                                         1.554
                                                                                                                                          2.111




                                                                                                                                                                                     2.111




                                                                                                                                                                                                                       2.111
       DESIGN                                                                                                           DESIGN                                                                                                               DESIGN
                                           1.569




                                                                  1.549




                                                                                           1.533




                                                                                                                                                                                                                                                                        1.546




                                                                                                                                                                                                                                                                                       1.554




                                                                                                                                                                                                                                                                                                         1.564
                                                                                                                                          1.904




                                                                                                                                                                                     2.290




                                                                                                                                                                                                                       2.096
       SURVEY                                                                                                           SURVEY                                                                                                               SURVEY
                                           -2.000




                                                                                                                                                                                                                                                                        -1.901
                                                                  0.000




                                                                                           2.000




                                                                                                                                          -2.802




                                                                                                                                                                                                                                                                                       0.000




                                                                                                                                                                                                                                                                                                         2.150
       OFFSET
                                                                                                                                                                                     0.000




                                                                                                                                                                                                                       2.874
                                                                                                                        OFFSET                                                                                                               OFFSET


                                                               CHAINAGE 0
                                                                                                                                                                            CHAINAGE 9.848                                                                                         CHAINAGE 0


                                                                                                   CROSS SECTION-DRIVEWAY 1                                                                                                                        CROSS SECTION-DRIVEWAY 2
                                                                                                   SCALE 1:100                                                                                                                                      SCALE 1:100




    360 CIVIL CONSULTING PTY LTD                                                   No      Date                  Amendment
                                                                                                                                                          Design:      J.A.G                            FOR APPROVAL           CLIENT:    JOHNSON COLES, JOHNSON, RANDALL & HUSSAIN                              JOB NUMBER
                        ABN: 13 609 593 339                                                                                                               Drawn:       J.A.G                                                   PROJECT:   PROPOSED DUPLEX DEVELOPMENT
BEATRICE GIBBERD RPEQ 14557 - DIRECTOR AND PRINCIPAL ENGINEER
                                                                                                                                                                                                                                                                                                                     2017115
           23 OOGAR STREET, MAROOCHYDORE. QLD 4558                                                                                                        Date:        04/11//17
                                                                                                                                                                                             BEATRICE GIBBERD RPEQ 14557       AT:   30-32 COCKLESHELL, NOOSAVILLE
                                                                                                                                                                                                                                                                                                                 DRAWING No:
   Mobile: 0403 862 009  Email: [email protected]                                                                                        Checked: B.G.                         DATE:      04/11/2017                LOT 11 ON RP138550 & 0 BUP6971
 THIS PLAN IS COPY PROTECTED BY 360 CIVIL CONSULTING PTY. LTD.
                                                                                                                                                              Datum:   A.H.D.                     Size:        A3              TITLE: DRIVEWAY CROSS SECTIONS
                                                                                                                                                                                                                                                                                                                  12 of 12

Page 20

Dr David Johnson & Suzanne & Adam Johnson
c/- Mr Michael Lyell
Adams & Sparkes Town Planning and Development
Brightwater Corporate Centre
Level 1, 69 Attenuata Drive
MOUNTAIN CREEK QLD 4557

Via email: -    [email protected]


11 March 2018


Dear Michael,

RE:   30 – 32 The Cockleshell, Noosaville
Engineering Response to Information Request

Please find below responses to the Noosa Council’s Information Request dated 10 January
2018 for the MCU at 30 – 32 The Cockleshell, Noosaville.

Please be advised that the below responses and attachments are a response to information
request items 7, 8 and 9 only.

Application No:                   MCU17/0563
Proposal:                         Development Permit for Material Change of Use
Street Address:                   30 – 32 The Cockleshell, Noosaville
Real Property Description:        Lot 11 RP138550 and Lot 0 BUP6971
Planning Scheme:                  The Noosa Plan (3 July 2017)

Issue
The submitted stormwater drainage plans do not adequately address the impact of the
development and the filling of the site on the drainage conditions on other properties.

Information Required Item 7
Provide a stormwater strategy/layout that caters for the stormwater runoffs from adjoining
properties and ensures no additional stormwater ponding or worsening of existing drainage
conditions to occur on these properties for all storm events up and including 1% AEP (1 in
100 year). This may require providing stormwater pipeline and/or defined overland
secondary flow path within the development site to convey natural stormwater runoff from
other properties into an existing stormwater system.

Page 21

Response to Item 7
Skyline Surveyors were able to provide additional survey, spot level information, on some
areas of the neighbouring sites. This information is attached for Council’s record. Please
note that in some locations access was not possible and Skyline obtained as best survey
level information as possible. The survey information indicates the following: -
     Lot CP BUP7701 appears to have a ridge through the middle of the site with the
        western portion of the lot falling to the street and the eastern portion of the lot
        falling to the rear of the site. Possible pond may occur in the north-eastern corner of
        the proposed development site. In order to alleviate this possible ponding a side
        grated pit is proposed in the base level of the retaining wall which will be connected
        to the development site’s internal drainage. This stormwater system is shown on
        amended 360 Civil Consulting Drawing No. 03 (Rev A).
     Lot 6 RP124554 has an internal stormwater pit and overland flow discharges to
        Thomas St via the existing driveway.
     Lot CP BUP7283 is lower than the development site and the survey levels indicate it
        falls towards Thomas St.
     Lot CP BUP6949 appears to be slightly lower than the development site and falls
        towards the street. The north-eastern corner of Lot CP BUP6949 appears to be
        approximately at a similar level to the development site and to address any possible
        ponding that may occur in this corner a side grated pit is proposed in the base level
        of the retaining wall which will be connected to the development site’s internal
        drainage. This stormwater system is shown on amended 360 Civil Consulting
        Drawing No. 03 (Rev A).


Issue
Further information and details are required regarding the existing Council’s stormwater
pipeline within Lot 0 BUP 6971 (No 32 The Cockleshell Street).

Information Required Item 8
Provide further information, details and/or amendments to address the following:
    a) The proposed development requires filling, increases load on the existing drainage
       pipeline on the site and will limit future opportunities for repair and/or upgrade.
       Also, there will be an increase in the flows in the pipeline due to the proposed
       development. As such, it is considered necessary that CCTV investigation of the
       existing pipeline (from The Cockleshell Street to Thomas Street) be carried out by the
       applicant determine the condition of the pipeline and report of investigation
       submitted to Council prior to issuing the OPW approval.
    b) A drainage easement must be created by the applicant over the subject stormwater
       pipeline at a width in compliance with Council’s standards and guidelines. Show the
       required easement on the amended plans.

Response to Item 8
   a) Please find attached to this response a preliminary stormwater CCTV report for the
      existing 375mm stormwater pipe that runs through 32 The Cockleshell, Noosaville.
      The CCTV commenced at The Cockleshell inlet pit and DrainsKleen have advised that

Page 22

       "the survey was abandoned - camera travelled downstream about 7m, before
       reaching, root mass which camera could not pass. Attempted reverse survey from
       other end but unable to access pit."

       The report and photos from DrainsKleen of the root mass is attached for council's
       information. Further clarification from DrainsKleen regarding the reverse survey was
       sought and the DrainsKleen operator who was on site has advised that: -

       "I was unable to locate the downstream pit (unsure if downstream pit exists or is just
       cut into another pipe). I am also unable to go from one of the neighbour pits on
       Thomas Street as I can't go around corners with robot camera due to risk of
       damaging equipment."

       Since this survey, Council have advised that, in due course, they will unblock the
       stormwater pipe and that no further work by this development is required in order
       to address this information request item.

       Reviewing the photographs provided in the DrainsKleen report the pipe that is visible
       appears to be in a reasonable condition.

   b) Please refer to the amended 360 Civil Consulting Drawing No. 03 (Rev 3) which
      details the 4m wide drainage easement over the existing council stormwater
      infrastructure.


Issue
Engineering plan/s is/are required for the details of the driveway grades and levels and
including a 2.0m wide pathway to confirm compliance with the relevant standard drawings
and for operational works construction.

Information Required Item 9
Provide an engineering plan and longitudinal cross section for the access driveway/s and
crossovers that include 2.0m wide pathway and demonstrates compliance with IPWEA
Standard Drawings RS-049 and RS-050 and have grades ensure a standard vehicle (B99),
entering or leaving the site will not scrape or bottom down.

Response to Item 9
Please refer to the amended 360 Civil Consulting Drawing No. 11 and 12 which detail a
driveway long section and relevant cross section drawings incorporating the 2m wide
footpath and compliance with IPWEA Drawings RS-049 and RS-050.

End of Responses to Information Request Items 7, 8 and 9.

Page 23

I trust that this addresses the engineering issues raised in Council’s Information Request
items 13 and 16. Please do not hesitate to contact me on 0403 862 009 should you have
any queries regarding any of the above matters or the attached drawings.

Yours sincerely,




Beatrice Gibberd
Director and Principal Engineer
360 Civil Consulting Pty Ltd

Attachments:
     Skyline Surveyors Contour and Detail Survey Plan No. 7534Det2
     360 Civil Consulting Drawings 01 to 12 of 12 (Job No. 2017115)
     DrainsKleen Stormwater Pipe Report dated 12/2/18

The text continues on page 24.