                                                                                                                                       Drains Kleen
                                                                                                                                        0424198467
                                                                                                                                 [email protected]
                                                                                                                                  www.drainskleen.com.au




                                                                    Conduit Inspection
         Date:                Asset owner's job ref.:               Asset Owner:               Operator :               Section number:                    Pipe Asset Id:
      12/02/2018                                                                             Jack Morrisby                     1                                 1/
  Time of inspection:                Cleaning:                   Standard:                        LRP                 Conduit Unit Length           Method of Inspection
      08:35:25                      not cleaned                WSA 05-2008 2.2            Centre of Start Node

Town:              Noosaville                              Catchment:                                                US MH:               1/1
Suburb:                                                    Asset Owner:                                              Survey Dir:          downstream
Street:            The Cockleshell                         Precipitation.:                                           DS MH:               2/1
Asset Location                                             Flow control            No measures                       Inspect Lenght :     6.32 m
Purpose of inspection :     New Construction                                             Shape :                  Circular
Use of Conduit:             Drain Surface Water                                          Dia/Height:              375 mm
Type of Conduit:            Gravity                                                      Lining:
Lining Method:                                                                           Pipe Material:           Reinforced concrete
Remarks :



         1:60      Position                  Code        Observation                                                                    MPEG       Photo         Grade




          1/1
                             0.00            WLT         Water level, turbid or discoloured flow, depth 50%                                                           0


                             0.00            STSP        Start node, side entry pit, Nodename: 1/1 , started slightly                   00:00:00        1_1A          0
                                                         in pipe due to roots in pit.




                             2.14               RT       Tap roots--a small number of major roots (10mm or                              00:01:55        1_3A          3
                                                         greater) without a significant mass of fine roots, at joint,
                                                         Obstruction: 5-20% , from 8 to 4 o'clock




                             6.31             GC         Unable to do reverse survey due to not being able to                                                         0
                                                         lacate downstream pit.

                             6.32             RM         A Mass of mostly fine Roots, which has developed into an                       00:05:17        1_4A          4
                                                         interwoven clump, at joint, Obstruction: 51-75% , from 2 to
                                                         10 o'clock
                             6.32            SAR         Inspection (survey) abandoned, roots, Survey abandoned                         00:05:28        1_5A          0
                                                         due to roots, unable to get camera pass.




 STR no def        STR peak          STR mean           STR total         STR grade       SER no def      SER peak           SER mean          SER total          SER grade
     0                  0                0                 0                  1                  2           50                9.49                60                  5
                                                         30-32 The Cockleshell St Noosaville SW // Page: 3
Log in to download the original file

Response to RFI - Council.pdf · 4.9 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.