Council archive · source document
DTMR Referral Agency Response · OPW11/0291
SCRC CORRESPONDENCE
I B0415276
11 Queensland
Government
File no: 215/00003(4)
P6869-MOM
P7087-MOM F46
C/c Attn: Mark Lewis
Senior Engineering Officer
Civil Engineering
Operational Works Assessment Branch
Sunshine Coast Regional Council
Locked Bag 72
Sunshine Coast Mail Centre Qld 4560
For your information.
Captain Richard C Johnson
Regional Harbour Master (Brisbane)
5 September 2011
/baq
Department of Transport and Main Roads
! 1119
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
Queensland
Government
5 September 2011 Department of
Transport and Main Roads
Noosa Jetty Builders
PO Box 299
Noosaville Qld 4566
Dear Sir
Operational Work, Prescribed Tidal Works - Request for comments
Jetty - D. Hadwen,109 Noosa Parade, Noosa Heads (Lot 66 RPN.1057.2)
Thank you for your letter of 20 August 2011 about your proposal to construct a jetty at the location
mentioned above.
As a concurrence agency, Maritime Safety Queensland has no objection to the proposal provided the
following navigation and marine safety conditions are complied with.
1. The contractor must build the jetty according to Noosa Jetty Builders, drawing 11/111-1, attached
to your letter dated 20 August 2011.
2. No part of the structure or any ship berthed at this structure is to come closer than I.51netres from
the side boundaries of the allocated water space as shown on the submitted water allocation plan.
3. The jetty and all freestanding piles must be lit and clearly visible to approaching vessels. The
contractor must position all lighting so it does not cause a risk to the safe navigation of other
vessels.
4. The applicant or his agent is responsible for the removal of any existing structure above or below
the waterline, and must contain and remove any debris. Any pile that needs to be removed must
be totally extracted.
5. The ship moored at this jetty must follow the most direct course from this structure to open waters
and a similar direct course when returning to this pontoon.
Department of Transport and Main Roads Our ref 215/00003(4) P6869-MOM P7087-MOM F46
Maritime Safety Queensland Your ref
Marine Operations (Brisbane) Enquiries James O'Connor
MacArthur Avenue East Telephone +61 7 3860 3504
Pinkenba Queensland 4008 Facsimile +61 7 3860 3571
Website www.msq.gld.gov.au
Email james.b.o'connor©msq.gld.gov.au
Page 3
6. The owner is to ensure that the ship berthed at this structure must maintain sufficient under keel
clearance at all stages of tide. The ship must comply with any local restrictions placed on channel
depths and draft restrictions.
7. Any ships and equipment you or your agent use must comply with the Transport Operations
(Marine Safety) Act 1994, the Transport Operations (Marine Safety) Regulation 2004 and the
Transport Operations (Marine Pollution) Act 1995.
8. Any ships using this structure must comply with the Transport Operations (Marine Safety) Act
1994 and the Transport Operations (Marine Safety) Regulation 2004.
9. Any ship moored at this jetty must not impede the safe navigation of other ships or restrict safe
access to or from neighbouring structures.
10. Any ship, dry berth or device (including Air Lifting Pontoons) berthed, moored or attached to the
jetty must not exceed the following sizes:
Wet Berth Dry Berth
Length Overall - 5 metres N/A
Beam - 3 metres
11. The contractor must construct the jetty within two years from the date of approval. If
construction is not completed, you will need additional or amended comments from the Regional
I-larbour Master.
Maritime Safety Queensland does not need to be further consulted if all of the above conditions are
met.
The above conditions must be included in your application to the assessment manager.
This agency will also forward a copy of this letter to the Assessment Manager.
Yours sincerely
Captain Richard C Johnson
Regional Harbour Master (Brisbane)
Page 2 of 2