22 A R A K O O N C R E S C E NT S U NS HINE BE A C H - F IR ST F L O O R PL A N
A B C D E F G H I J K L M N O P
24.000
6.000 1.500 4.500 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000 1.000
20
S01
S03
21
1
4.5M)
(BELOW
S ID E S ETBACK
22 1.5m -7.5M)
100x50mm HWD 0.234 CK (4.5M
72˚28' 4 E SETBA
BATTEN SCREEN
E BOUN
DARY 2.0m SID -8M)
SIT CK (7.5M
E SETBA
OUTDOOR HAND
23
2 2.5m SID
HELD SHOWER &
WALL HOOKS 24
BIFOLD GATE 25
AWNING BELOW
LINE OF EXISTING APPROVED FALL 3˚
26 FL-1
PLANS SHOWN AS DASHED
27 PLANTER
28 dp1
GU1
1 BIN/UTILITIES
FALL 3˚
1 RS-01
+28.33 SAFYA ROOF
2.000
FALL ANCHOR FALL 3˚ FALL 3˚ FALL 3˚ FALL 3˚
GU1
GU1
CARPORT G02 PLANTER
ACCESS LINE FL-1 RS-01 RS-01 FL-1
2 G01 ROOF
FOYER
3 PERGOLA 3
APPROVED ABOVE +29.050 SOLAR
1.100
DESIGN +29.045 FALL 3˚
STORE FL-1
SECTION +28.949
4 dp1 4
17
17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 GU1
ENTRY
1.500
FALL
OWN AS DASHED
S02
STAIR 1 FALL 3˚
29
RS-01
5 5
1.100
VOID LINE
LINEOF
OFEXISTING
EXISTINGAPPROVED
APPROVEDPLAN
PLANSHOWN
SHOWNAS
ASDASHED
DASHED FALL 3˚
RS-01
N SH
6 6
APPROVED PLA
SITE BOUNDARY
FALL 3˚
GU1
LIFT RS-01
SKY GARDEN
3.700
VOID
LINE OF EXISTING
GARAGE
30
GU1
+29.070
346˚18' 12.448
dp1
FALL 3˚
dp1 FL-1 2.5m SIDE SETBACK (7.5M-8M)
LINE OF EXISTING APPROVED PLAN SHOWN AS DASHED
7 7
SC03 2.0m SIDE SETBACK (4.5M-7.5M)
1.5m SIDE SETBACK (BELOW 4.5M)
1.905
+29.246
8 8
SITE BOUNDARY 260˚08' 40.234
12m SETBACK
15m SETBACK
LINE OF EXISTING APPROVED
PLANS SHOWN AS DASHED
NOTES
1. ALL ROOF WATER TO BE COLLECTED AND
S01
S03
DIRECTED TO STREET KERB AND CHANNEL
A B C D E F G H I J K L M N O P
DA ISSUE
Use figured dimensions in preference to scale.
All dimensions to be verified and checked on
ISSUE REV
ROBINSON CLIENT PROJECT DRAWING TITLE REVISION DRAWING NUMBER
site. These designs, drawings, specifications
SKETCH DESIGN SD-1 06/10/2022 03/11/2022 ARCHITECTS KEITH & JEANNETTE LOT 793RP48111 FIRST FLOOR PLAN DA-2 107
and the copyright thereof are the property of DA DESIGN APPROVAL DA-2 09/12/2022 14/12/2022 67 MEMORIAL DRIVE INCE 22 Arakoon Cres
Robinson Architects Pty Ltd and must not be
EUMUNDI Q 4562 Sunshine Beach Q 4567 DATE SCALE
used, retained or copied without the written
authority of Robinson Architects Pty Ltd. Ph. (07) 5442 8566 DA ISSUE © ROBINSON ARCHITECTS 2022 14/12/2022 (A3 Paper)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Proposal Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.4 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.