Council archive · source document
Appendix4-SlopeStabilityAssessment · MCU18/0135
Attached to the e-mail Detached House (Report, Slope Stability, Proposal Plans, Landscaping, Engineering, DA Form) - MCU18/0135.
Lab Results/Predicted Surface Movement Bore Hole N/A Shrink-Swell N/A Ys N/A Existing Retaining Walls Nil Site Description Future Site Works: Unknown Existing Earthworks: Nil Vegetation: Heavily grassed, scattered small to medium sized trees Slope: 12-20% Allotment Type: Residential Surrounding Allotments: Road to the right,vacant to the left and a bushland reserve to the rear. Surface Water: Surface water from adjoining allotments will traverse this site. Watercourses: Nil Road Status: Sealed Important Notes *Earthworks could affect the site classification and or founding depth. *If any fill is placed on the allotment post investigation the founding depth will change, furthermore placement of reactive fill may change the sites classification. *All top soil and vegetation is to be removed. *Surface water is to be diverted away from structure. *Do not plant trees near the structure which could interfere with the footings performance. *It is the owner’s responsibility to read and understand the CSIRO BTF 18 Foundation Maintenance and Footing Performance: A Home-owner’s Guide. *Strength of founding material can be highly variable dependent upon moisture content. *This investigation undertaken consisted of 2 boreholes only, given the size of the site it is possible that a problem could have been missed. eg. Filled dam/gully, soft soils, fill, springs, boulders, rock etc. We cannot give a definitive assurance that none of these problems exist on the site unless we did a greater number of boreholes which would be uneconomical and impractical. *This report may not provide all necessary information to design an adequate footing system, further investigation may be required using larger drill rigs and/or different testing methods. Trees Unless otherwise stated this report assumes that all trees near the site that could influence the performance of the footings will be removed and/or will be allowed for in the designing engineers design. Therefore, this report excludes the potential effect any trees nearby may have on the structure. Distance from proposed structure that trees can effect footings: 0.75 x 'h' 'M' sites 1.0 x 'h' 'H' sites 1.5 x 'h' 'E' Sites 'h' is the mature height of the tree. Where there are rows of trees the distance should be increased. It is the designing engineer’s responsibility to calculate the yt and add it to the ys.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix4-SlopeStabilityAssessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.