Original source · versioned page text
Amended proposed plans - DA 3
Attached to the e-mail FW MCU220086 - Council information request.msg.
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn NORTH
NOTES: REVISION
No. DATE DESCRIPTION ISS. BY
LICENSED PLUMBER TO VERIFY DOWNPIPE
DECK ABOVE
NUMBERS AND POSITIONS PRIOR TO
CONSTRUCTION OR ORDERING
PLATFORM IMMEDIATELY SURROUNDING DWELLING
TO FALL AWAY AT A SLOPE OF 1 IN 20. SURFACE
DRAINAGE TO DISCHARGE EVENLY WITHOUT
NUISANCE TO ADJOINING PROPERTIES
SITE TO BE SCRAPED CLEAN OF VEGETATION TO
BUILDING AREA
ALL LEVELS SHOWN ARE INDICATIVE ONLY AND ARE
TO BE CONFIRMED ON SITE. NO RESPONSIBILITY
TAKEN FOR ANY LEVELS SHOWN. SURVEYORS
PLANS TO TAKE PRECEDENCE OVER ANY LEVELS ENGINEERS TO SPECIFY
SHOWN ON THESE DOCUMENTS HOUSE POSTS FOR DOUBLE
LANDING BEARERS
ABOVE DECK ABOVE
PLUMBER TO DESIGN GROUNDWATER DRAINAGE HOUSE
ABOVE
SYSTEM. ONE (1) YARD GULLY STANDARD ABOVE
NOTE: ENGINEERS DETAILS, DRAWINGS &
SPECIFICATIONS TO TAKE PRECEDENCE OVER
THESE DRAWINGS
BUILDER TO VERIFY ALL DIMENSIONS PRIOR TO HOUSE ABOVE
ORDERING ANY MATERIALS
SEAL ALL WET AREAS IN ACCORDANCE WITH AS
3740 & BCA REQUIREMENTS GRAVAL PAD ON GROUND
REFER TO ENGINEER'S
PLUMBER RESPONSIBLE TO LOCATE AND CONFIRM NEW DRAWINGS AND
SEWER HOUSE CONNECTION LOCATION DECK SPECIFICATIONS
ACCURATELY PRIOR TO COMMENCEMENT. ABOVE
PLUMBER IS TO VERIFY WITH SITE SUPERVISOR
PRIOR TO SETTING OUT FIXTURE DRAINAGE HOUSE ABOVE SSL 140200
DECK ABOVE
POINTS. NO AMENDMENTS OR SPECIAL FIXTURES
HAVE BEEN NOMINATED
REFER TO SPECIFICATION FOR ALL CONCRETE
SLAB FINISHES
WHERE SERVICES / PIPEWORK ARE LOCATED
UNDER DRIVEWAYS AND SLABS CONTRACTORS
ARE TO ENSURE ADEQUATE COMPACTION TO
TRENCH BACKFILL ACHIEVED TO SUPPORT
CONCRETE
D. A.
REBATE GARAGE DOORS & SLIDING GLASS DOORS
20mm, AND SHOWER RECESSES 40mm IN
PROPOSED DRIVEWAY
E OR
F TION
U
LOCATIONS SHOWN ACCORDING TO MANUF' SPEC.
ISS FOR CO TRUC
OR BUILDERS DIRECTIONS
N S
DEVELOPMENT SEWER CONNECTION DETAILS NOT
AND INFORMATION WAS UNAVAILABLE AT THE
TIME OF WORKING DRAWINGS PREPARATION.
matt bradley designs
©MATT BRADLEY DESIGNS - ACN: 637 963 396 - ABN: 53 637 963 396
PLUMBER IS RESPONSIBLE TO DETERMINE www.mattbradleydesigns.com.au - [email protected] - 0488 554 020
ALL DESIGN, CONSTRUCTION METHODS & MATERIALS TO BE IN ACCORDANCE WITH:
CONNECTION INFORMATION FROM DEVELOPER - THE BUILDING CODE OF AUSTRALIA (BCA);
- THE QUEENSLAND DEVELOPER CODE (QDC);
- BUILDING REGULATIONS;
AND TO COMPLY WITH ALL RELEVANT DETAILS - CURRENT ISSUES OF AUSTRALIAN STANDARDS & MANUFACTURER'S
SPECIFICATIONS & INSTALLATION DETAILS FOR MATERIALS USED.
AND REQUIREMENTS DIMENSIONS ARE SUBJECT TO SITE MEASUREMENT & VERIFICATION.
DO NOT SCALE OFF THIS DRAWING. PLANS COPYRIGHT MATT BRADLEY DESIGNS PTY
PROJECT ADDRESS
411 BLACK PINCH ROAD,COOTHARABA
QLD 4565
SUBTERRANEAN TERMITES: DRAWING TITLE
SUBTERRANEAN TERMITE PROTECTION TO BE IN
NEW POST / SLAB SETOUT
ACCORDANCE WITH AS 3660. KORDON PHYSICAL
TERMITE BARRIER TO PERIMETER AND ALL SLAB
PLAN
PROTRUSIONS / PENETRATIONS. 80MM MIN CLIENT
MATT PAVELICH AND JUSTINE OXLEY
EXPOSED SLAB FACE TO PERIMETER TO ACT AS DRAWN
VISUAL DETECTION SYSTEM AGAINST TERMITE KD/EB
INFESTATION AS PER AS3660 AND ALL RELATED SCALE
1 : 100 @ A3
CODES. ANY OTHER SYSTEM USED MUST BE A DATE
CERTIFIED SYSTEM TO BCA REQUIREMENTS. 2022-08-17
PROJECT NO.
2022032
0 0.5 1 2 3 4 5 10 DRAWING NO.
WD-08 rev:
QBCC LICENCE: 15025395
SCALE = 1:100
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.