Council archive · source document
20241119-Response to further advice notice · MCU21/0228.02
. Advice required 3. Provide revised plans identifying the area above Unit 2’s bedrooms, and detail works to demonstrate compliance with plot ratio requirements. 4. Provide a copy of the development’s total gross floor area calculations. Response to item 2. In response to items 3 & 4 above, we provide amended plans which illustrate the dimensions of the non-habitable space in the roof cavity (refer to Appendix B). This space results in an additional 58m2 of GFA, which increases the plot ratio to 0.59:1, exceeding the allowable plot ratio of 0.5:1. Notwithstanding this, the applicant’s private certifier (Pure Building Approvals) has confirmed that the space is non- habitable in accordance with the requirements of the National Construction Code (NCC). Pure Building Approvals has prepared a letter (refer to Attachment C) confirming that the space is not a habitable room due to the space not having sufficient ceiling height. The area is basically an additional storage area for Unit 2 and can only be accessed via a drop down ladder arrangement and small sliding door, which are generally only appropriate when providing occasional access to a non-habitable room. It is understood that the current tenant also uses the area as a kids play area, on a temporary basis. In light of the area only comprising a non-habitable space, we therefore seek Council’s endorsement to retain the space as a temporary storage and occasional child play area. We do not believe that this adversely affects the residence being utilised as intended, nor impacts the external built form. The use of this area could be further addressed through reasonable and relevant conditions of approval to ensure that this non-habitable space remains primarily for storage and occasional play space. Item 3 – Balcony 2 of Unit 2 Condition 14 requires - All deck and balcony areas above ground floor must not be enclosed by permanent fixtures such as shutters, louvres, glass panelling or the like, except where required to satisfy any privacy condition of this Decision Notice. On site inspection it is clear that “Balcony 2” is fully enclosed. For this area not to contribute to gross floor area structural changes will be required. Advice Required 5. Provide revised plans and detail works to demonstrate compliance with plot ratio and height requirements. 6. Provide a copy of the development’s total gross floor area calculations. Response We understand that Council has concerns that balcony 2 is an enclosed space contrary to Condition 14 stated above. However, we also note that Condition 18 includes the following which conflicts with the “non- enclosure” requirement of condition 14: JFP Ref: M2915P Page 4
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20241119-Response to further advice notice.pdfRelated documentApplication case desk ↗
About this file
- File size
- 767 KB (small file)
- File type
No other editions are linked here.