Council archive · source document
07/0012 - Lot Reconfiguration & MCU [As Published] · 132007.12
BS. URBAN STRATEGIES (SUNSHINE COAST) PTY LTO ve TOWN PLANNING ASSESSMENT REPORT v Sere ice T! kel steko eed Proposal Compliance d) ensure filling or excavation does not b) the infrastructure has the adversely impact upon other premises capacity to accept any by— additional loading; i. causing ponding on the site or AND nearby land; $18.3 For Detached houses N/A The proposal does not NIA ii. increasing flooding, which and Multiple housing— involve residential uses. adversely affects the safety or use | a) where slab on ground of any land upstream and construction is used, filling downstream; and does not extend more than iii, adversely affecting the flow of 4m beyond the building water in any overland flow path. footprint, measured from the outer walls of the building ; or b) the design consists of a suspended floor construction. Sloping sites & ridgelines $19.1 Buildings and N/A The site is not considered a N/A 019 Development on sloping sites— associated accessways are ‘sloping site’ as gradient does a) is responsive to the natural topography | not constructed on land with a | not exceed 1 in 5 or 20%. of the site and minimises cut and fill; slope greater than 25% (1 in b) does not visually dominate the hill 4); slope or interrupt the skyline; AND 2 c) is integrated with the natural site $19.2 Buildings are of split characteristics including vegetation; level design that step down ? and d) for Multiple housing, takes the form of small separate buildings; AND 020 On steep siopes or ridgelines which are visible from the major road network, areas of public open space, the Noosa River or the beaches— a) new buildings and structures including outbuildings, are designed so as not to dominate or detract from the scenic and environmental qualities of the site and its setting. the slope or have suspended floor construction; AND $19.3 Cut or fill is tess than 1.2m in depth; AND $19.4 The distance between the ground and the lowest part of the floor of the building does not exceed 3m to avoid large under building areas; AND $19.5 Buildings present no more than 2 or 3 storeys at any one point. $20.1 No solution provided 2007 I ch FRONT cou ~ VED ~ Roof form $21.1 The main roof of the The main roofline has a pitch of v 021 Rooflines— building has a roof pitch no 7° and roof overhangs a a) contribute positively to the local less than 5 degrees and has minimum of 600mm are skyline; roof overhangs a minimum of provided throughout the b) complement the character of the 600mm wide; and development. locality; ¢) are articulated, pitched or skillion; $21.2 Buildings and structures | The proposal does not include v d) avoid low pitched (eg. less than 5 do not include roof top rooftop terraces. degrees) or box roof profiles/parapets; | terraces. e) donot create opportunities for residents to averlook the private open space areas of neighbouring properties. Materials and finishes No solution provided. A range of materials and colours v 022 Buildings and other structures use materials and finishes that complement the Noosaville character and integrate with the surrounding natural and built environment by— a) using a mix of lightweight and textured external building materials, including timber finishes; and b) using masonry construction where variation is provided in texture, detailing and the like. are proposed, including rendered and painted blockwork and FC sheeting, colourbond customorb cladding and roofing and slat screens in metal frames. The materials and colours are in keeping with the existing and approved buildings on site. The varied materials and colours and articulation in roof form creates visual interest to the built form, in keeping with surrounding environment and Noosaville character. MATERIAL CHANGE OF USE & RECONFIGURING A LOT 88 & 90 GOODCHAP STREET, NOOSAVILLE 10
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0012 - Lot Reconfiguration & MCU [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.