07/0012 - Lot Reconfiguration & MCU [As Published] · 132007.12
URBAN STRATEGIES (SUNSHINE COAST) PTY LTD
TOWN PLANNING ASSESSMENT REPORT
BS.
wv
wv
v
Ey atic en ey
Liked *F cake Co LbeSd
Proposal
The subject site provides a
range of supporting services to
these surrounding community
uses. The proposed education
use and extension to medical
uses will further support these
surrounding uses and promote
collocation of community
facilities
Compliance
Car Parking & Access
0184 Access to Lot 1 on RP900855 is
obtained from Goodchap Street via a
maximum of 3 crossovers.
No solution provided.
The proposal does not seek to
change existing access
arrangements to Goodchap
Street.
6.3.2 Business Uses Code
Division 14-16 — Specific Outcomes and Probable Solutions for the Business Uses Code
Table 14-5 For all Business Uses
Specific Outcomes ake ely Proposal Compliance
14.71, Effects of use
Electricity infrastructure $1.1 No solution provided The proposal will not impact v
O1 The development does not adversely existing or future electricity
impact on existing or future electricity supply infrastructure.
supply infrastructure; AND
02 All uses and works maintain an $2.1 Oevelopment for uses N/A The site is not located NIA
adequate safe distance from electrical adjacent to or within 50m of an | within 50m of an existing
infrastructure including substations, existing electricity substation electricity substation or within
overhead powerlines, power poles and incorporates noise attenuation | close proximity of overhead
transformers. measures to mitigate noise electricity transmission lines or
impacts; electricity easements.
AND
$2.2 Buildings and structures | The stage 2 building and v
{including swimming poois, carparking structure are not
sheds, tennis courts and constructed under overhead
outbuildings) are not electricity transmission lines, or
constructed under overhead within electricity easements
electricity transmission lines,
or within electricity easements.
14.18 Amenity .
Noise No solution provided The carparking structure is v
O3 Development is designed and sited to setback 3m from the western
avoid noise emissions that unreasonably boundary, which adjoins
diminish the amenity of the area or residential zoned land. The
Surrounding uses. setback will be landscaped to
maintain visual amenity and
solid boundary fencing together
with solid block work around the
western elevation of the carpark
will mitigate potential noise
nuisance on the adjoining
residences.
Mechanical plant and equipment and $4.1 Mechanical plant and Mechanical plant and equipment v
storage areas equipment are— will not be located within 2m of
O4 Mechanical plant and equipment a) located more than 2m from | any boundary and will be
(including air conditioning equipment) and any property boundary; appropriately integrated into the
storage areas are designed and located b) where located at ground overall building design and 1
to— level, screened by fencing screened where nege ~
a) avoid adverse visual impacts when 1.5m in height or dense be oN
viewed from the street and adjoining vegetation of at least 1.5m ™ .
properties; and in width incorporating \
b) visually integrate with the building grouped trees and shrubs ,
design. with maximum separation ¥ E 5 ‘ \
distance of 1m measured anes —-
from the centre of the tree 2007
or scrub; and 1
c) are visually integrated into noosa SHIRE ChuNcy,
the line and plane of the aehT COTE
MATERIAL CHANGE OF USE & RECONFIGURING A LOT
88 & 30 GOODCHAP STREET, NOOSAVILLE
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0012 - Lot Reconfiguration & MCU [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.