Council archive · source document
07/0012 - Lot Reconfiguration & MCU [As Published] · 132007.12
wv g w URBAN STRATEGIES (SUNSHINE COAST) PTY LTD vv TOWN PLANNING ASSESSMENT REPORT v * has a minimum width of 2m along the site boundaries; « provide plantings in mulched areas along boundaries and carparking which provide screening and shading; ® not require an excessive amount of water; = facilitate infiltration of stormwater, thereby minimising runoff; and = utilise low maintenance, native plants complementary to the character of the area. 6.3.6 Engineering Works Codes The proposed extension includes additional carparking in accordance with the Driveways and Carparking Code. The new two storey carparking structure will accommodate 100 carparks and has been designed in accordance with the Code and Policy. A surplus of spaces over and above the code requirements will be available on site upon completion of the development. The carparking area under the stage 2 building has been altered to accommodate 28 bicycle parking spaces. A further 6 spaces are provided in stage 1 of the development. Table 14- 48 of the Code requires 1 bicycle parking space per 50m? or part, thereof gross floor area of commercial businesses and for education uses 1 space per 30m? or part 1 thereof gross floor area. The proposed extension of 540m? commercial business and 860m? of education floor area, generates a requirement of 40 bicycle parking spaces (540/50=11 + 860/30=29). A shortfall in bicycle parking results, however given the nature of the education use being for adult education and the surplus of carparking on site, the proposed provision of bicycle spaces is adequate. The required rate for education uses is the same for child care, schools and adult education. Schools have a localised catchment and are accessed by a large number of people on bicycles. The proposed education use however is for adult education, which will have a much broader catchment area, therefore is unlikely to generate bicycle trips at the same rate as other education uses. A traffic engineering report is being prepared by 77M Consulting and will be submitted under separate cover. The report will include a detailed assessment of exiting and forecasted traffic volumes (10 year horizon) and estimated future traffic demands of the proposed extension. Surrounding road network performance, queue distances, adequacy of access and parking will also be assessed. Initial advice received from TTM indicates that the proposed additional use area and new carpark design will comply with applicable Australian Standards and AUSTROADS and is unlikely to have an adverse impact on the safety or operation of the surrounding road network. More detailed assessment against the engineering works codes will be undertaken at operational works and building works application stages. 6.3.7 Natural Hazards Overlay Code The site is identified on Natural Hazards Overlay Map OM8.4 as partly High and partly Low Potential Acid Sulfate Area and partly a Medium Bushfire Hazard Area. As highlighted in section 6.2 above the proposal will not involve filling the land or excavating more than 100m? of material at or below 5mAHD, therefore the Acid Sulfate Soil provisions of this Code are not applicable. In addition, although identified as presenting bushfire hazard on the overlay map, the site is clear of vegetation. While the site is adjoined by vegetated parkland, appropriate fire services will be provided within the development. In the event a fire hazard MATERIAL CHANGE OF USE & RECONFIGURING A LOT 88 & 30 GOODCHAP STREET, NOOSAVILLE 20
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0012 - Lot Reconfiguration & MCU [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.