Altered Plans 28 Crystal St Cooroy 27-04-20 · OPW20/0083

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
                                                                                                                                                                                                                                                    17976
                                                                                                                                                                                                   105 70         70           70              70                       70              70                       70
                                                                                                                                               2740                                    2971                 900         1000         900            937          1000             800               2084                              3666

  Notes for Construction & Maintenance of Timber Decks:
                                                                                                                                                                                                              Concrete Path
  Builder to adhere manufactures specifications or industry standards at all times &                                                                                                    2426                0906                                              Entry Door                                                               1218
  Owners to follow manufactures details for maintenance & cleaning of deck                                                                                                            Rolla-door             SW                                                                                                                        SW
  All timber posts to be naturally durable Class 1 or 2 above ground or softwoods H3 treated if                                                                                                                                                                   820
  supported on bracket if in ground to be H5 Treated soft or hardwood.




                                                                                                                                                                                                                                                                                                                 770
                                                                                                                                                                                                                                     Storage


                                                                                                                                                                                                                                                    Storage
                                                                                                                                                                                                                                                                                               Bathroom




                                                                                                                                                                                                                                                                                                                                                                                                    1600
                                                                                                                            1650
  Recommend brackets or supports be used & Bitumen paint be applied to the top 200 mm of                                                                                                                                 VTY                                                      SHR                       EF
                                                                                                                                                                                                             WC                                                                                                                       Carpet
  bracket in the concrete.




                                                                                                                                                                                                                  720


                                                                                                                                                                                                                               720




                                                                                                                                                                                                                                                                                                                                                                                                           3300
  Posts to have a Minimum 75 mm clearance from the base of the post to footing or slab & post to                                                                                                                                                                                                                                     Bedroom




                                                                                                                                                                                                                                                                                                                                                                                                            70
                                                                                                                       70
                                                                                                                                                                                                                                                    720
  be 10 mm above cross member of bracket. End grain of post to be sealed prior to erecting.                                                                                                                                                                                                                                               CF




                                                                                                                                                                           1218
                                                                                                                                                   Drive Through Carport

                                                                                                                                                                           SW
                                                                                                                                                                                                                                                                                                                          S




                                                                                                                                                                                                                                                                                                                 720
                                                                                                                                                                                                                                                                        Laundry
  Top of concrete pad footing to be mounded to fall away from support to prevent water from                                                                                                                                                                                       WM




                                                                                                                                                                                                                                                                                                                                                                                                    1630
                                                                                                                                                                                                                                                                                                    WIR                             Openings
                                                                                                                                                                                                                                                                                                                               300x900 - 3000 to top
  ponding
                                                                                                                                                                                                                                                                                  Tub
  Bearers, Hardwood to be H3 treated if less than 400 mm above ground H4 for touching ground H5




                                                                                                                                                                                                                                                                                                                                                                                                                7500 O/All
                                                                                                                                                                                                                                                                                                                                                                                                                     70
                                                                                                                                                                                                                                                                                                                         820
  for in ground.
                                                                                                                                                                                                                                                      S             S                                                          REF
  Joists as bearers depending on ground clearance. Joists to have Malthoid strip or bituminous
  paper fixed to top of joists. Softwood & Engineered manufactured timbers bearers & joists to be                                                                                                                                                                                             Concrete Floor
  H3 min treated at all times. Approved connectors be used for treated timbers & location.                                                                                            Garage




                                                                                                                                                                                                                                                                                                                                                              (Cabinetry by Others)
                                                                                                                                                                                                                                                                                   Secondary Residence




                                                                                                                                                                                                                                                                                                                                                                                             0918
                                                                                                                                                                                                                                                                                                                                               Kitchen Area




                                                                                                                                                                                                                                                                                                                                                                                              SW
  Recommend hot dip galvanized or stainless steel connectors & fixings be used at all times.                                                  Concrete Floor                                                           Concrete Floor
                                                                                                                                                                                                                                                                                              Living Area




                                                                                                                                                                                                                                                                                                                                                                                                             3840
  Especially where inspections are not possible deck is to close to ground or decking to be screwed                                                                                                                      Workshop                                                 CF                                CF
  in place to allow for easy removal to inspect sub-floor for any issues
  Timber Queensland recommend that all timber has a moisture content of 15%




                                                                                                                                                                                                                                                                                                                                                                          UBO

                                                                                                                                                                                                                                                                                                                                                                                      HP
  Decking boards to be fixed with 2/nails or screws & staggered or offset along the joists. Holes at
  ends of boards to be drilled holes to be 80% of nail diameter & 12mm from ends of boards. Nails
  & screws to finish flush with top of boards (Not Punched). Nails or screws to be hot dipped
  galvanized or stainless steel. Stainless Steel to be used within 900 mm of pools                                                                                                      1218                                 1218                                                            2130                                          1218
  All Framing Anchors, Fixing Plates, Nailing Plates, Joist hangers to be Galvanised Minimum or                                                                                          SW                                   SW                                                             AStD                                          SW




                                                                                                                                                                                                                                                                                                                                                                                                             2380
  Stainless Steel where Construction within 2.0 km radius of open coastal areas




                                                                                                                                                                                                                                                                                                                                                                                                                     2470
                                                                                                                                                  70x35 MGP10 Timber frame to                                                                                                                       Timber Deck
  Ends of boards to be slightly undercut at joints. Gaps between decking boards to be min 3 mm to                                         Steel Portal Frame provided by Manufacturer
  5 mm                                                                                                                             Dimensions may vary depending on positions of Portal Frame
  (Check with supplier Gaps range with different Types of timbers)                                                                   and wall thickness required to cover steel portal framing




                                                                                                                                                                                                                                                                                                                                                                                                                90
  Decking boards to be fully sealed (Oiled, Stained, Painted etc.) prior to fixing.                                                Secondary Residence Floor area to be No Larger than 65 m²
                                                                                                                                                   As plans drawn approx 61 m²
  Recommend a light coloured sealer, with UV protection and a fungicide to be used
                                                                                                                                       Secondary Residence Area:                    60.9 m²
                                                                                                                                       Timber Deck:                                 12.4 m²
                                                                                                                                                                                                                                                                                        2365                           2365
  Maintenance & inspection of deck by Owner is to be carried out regularly                                                             Workshop, WC Storage Area:                   31.1 m²                                                                             90                             90                            90
  Sweep or blow, leaf or other debris off deck. Hosing or use of water to be avoided. Keep the gaps                                    Garage Area:                                 22.4 m²                                                                                                           5000                                                    2120
  between decking boards clear of dirt & debris.                                                                                       Carport Area:                                20.6 m²
                                                                                                                                       TOTAL AREA:                                 147.4 m²                                 4134                                                                             7760
  Reseal decking boards when required by manufactures recommendations
  Inspect all connections for corrosion or movement regularly (Twice Yearly)                                                                                                                                                                                                                                                                                                                        S :         Smoke Detectors
  Pot plants to be on stands with a drip tray underneath & moved around regularly to prevent                                                                                                                                                                                                                                                                                                        CF:         Ceiling Fans
  uneven weathering of the deck                                                                                                                                                                                                                                                                                                                                                                     EF:         Exhaust Fan
                                                                                                                                                                                                                                                                                                                                                                                                    UBO:        Under Bench Oven
                                                                                                                                                                                                                                                                                                                                                                                                    HP:         Hot Plates
  Accolade Building Designs recommends that Builder & Home Owners read Domestic Deck Design                                                                                                                                                                                                                                                                                                         REF:        Fridge Space
  Guide
  Available on line www.timber.net.au




                                                                                                                                                                                                                                           2nd Residence Plan
                                                                                                                                                                                                                         1                     1 : 100



Plans Altered to Suit changes made during Building
Materials Used & position of Building


Client: Brad Allen                      Address: 28 Crystal St. Cooroy                                  Noosa Shire Council                                                                                                                                                    Mobile: 0407 693 018        Date     27/04/2020 11:33:07 AM
                                                                                                                                                                                  ACCOLADE Building Designs                                                                                                Drawn by; S.Horn Drawn for A3 Sheet
RPD: Lot 27 on RP 32777                              Site Area : 1374.8 m²                    Wind Classification N3                                                                     Proprietor: Steven Horn                                                        Email: [email protected]
                                                                                                                                                                                                                                                                                                                                                                                           Project Number                    1118AB28
Proposed 2nd Residence, Carport & Workshop on SHS posts & Concrete, Timber Frame, Sheet Roof                                                                                              QBSA Lic. 54806                                                               Issue Date:                        27 - APRIL - 2020                                                               Scale     1 : 100 Sheet No. 2           of 7

Used in these records

About this file

File size
553 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Altered Plans 28 Crystal St Cooroy 27-04-20.pdf · 553 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.