Ltr-240820 - Lot 17 - 19 Hofmann Drive Noosaville - Noosa Shire Council Minor Change_V2
Modification of the driveway footprint to comply with basement ramp requirements and AS2890.1
standards;
Redesign of the gatehouse and letterbox to meet Australia Post standards;
Conversion of the mechanical riser space into a raised planter, as it is no longer required for
Building C;
Adjustments to the extent of screening atop planter walls;
Modifications to block walls and fencing in courtyards overlooking OS7 to enhance amenity and
improve light and views for unit living areas, while maintaining bedroom privacy (Building C Level 1
South Eastern Elevation).
Building Design and Material Modifications:
Addition of metal roof sheeting above the concrete roof for improved rainfall management and
durability (Building A and B entry);
Installation of metal roof sheeting over barbecues, pool pump, and amenities for environmental
protection and durability;
Reconfiguration of the fire stair layout to provide access to the plant room (Building A Level 1);
Replacement of the solid wall north of plant rooms with louvers (Building A Level 1 – 3);
Amendment of balustrade code from BAL5 to BAL10 (Building A Level 2 and 3 balustrade BAL5);
Addition of mechanical roof vents and exhaust fans to Buildings A, B, and C;
Adjustment to the extent of screening atop planter walls (Planter between Building B and car park);
Removal of windows (windows to unit 2C facing plant deck);
Height adjustment of windows to meet fire separation requirements between levels (Building A, B,
and C Level 2 and 3 windows above building entry);
Replacement of rendered block wall finish with FC3 fibre cement cladding (Building C rendered
block wall adjacent to building entry);
Replacement of the solid wall west of plant rooms and screening north of the plant room with
louvers; Addition of a cleaners room (Building C Level 3 lobby);
Relocation of a door on Level 1 of Building C from the car park to the bin room;
Adjustment to the location of two storage cages within the basement.
Infrastructure and Utility Modifications:
Installation of solar panels (Building C);
Addition of a Fire Indicator Panel (FIP) to meet fire services requirements (Building C Level 1
lobby).
All of the abovementioned changes are included within the revised set of Architectural Plans. Please
see Attachment D for complete details.
Ltr-240820 - Lot 17 - 19 Hofmann Drive Noosaville - Noosa Shire Council Minor Change_V2 13