Council archive · source document
Updated plans 23.3.22 · 51980.2682.01
Plans and drawings: the text below has words only, no drawings.
B
E
3.01
R
NEW stair 02
3.01
LEGEND
B
A
R
REBUILD TO PROFILE OF EXISTING
allow clearances for EXISTING STAIR 02
NEW block wall
I M
nose-under parking as driveway supporting stair P1 Structural Post - type 01
existing
required second exit to
REMOVE existing
EXISTING
satisfy P2 Structural Post - type 02
NCC D1.4 block wall & stair 01 P3 Structural Post - type 03
A
NEW stepped block Exit travel distances reduce stair width NEW REMODEL CJ construction joint
clause (c)(i) 21 d door
boundary fence DP 43 landing existing stair
R
no point on a floor must dp downpipe
150
O
DP100 be more than 20 m from NEW store C-01 fhr fire hose reel
an exit, or a point from FFL finished floor level
in block grated drain
W
which travel in different g gate
core ac directions to 2 exits is150 150 ga garden bed
available DP DP lift fall hc hose tap
ac EXTEND existing hws hot water system
ac DP150 balcony slab to lb letter box
meter
C
fall accomodate RL relative level
C-01 EXISTING
1200
7 box sd sliding door
RL
RL
.6 fhr landing for lift
RL
2 field inlet
22
22
L2 shw shower
2
D105 D104 D103 D102 D101
2.
.7
.6
180
R IL 22.36
6
st store
2
8
M F
B
7
sk sink
site 0" 26.
°02'0
36 SSL structural slab level
vp vent pipe
boun
wp waste pipe
0" 26.0
NEW NEW
25°44'4 undary
AS EXISTING w window
dary 52
NEW Kitchenette Kitchen wc toilet
NEW Kitchen Male & Female -ette NEW wall - 90 stud
1
WC
site bo
01 NEW Kitchenette -ette EXISTING 01 NEW wall - Conc. Block
Kitchen tree EXISTING wall
3.02 EXISTING to remain
3.02
-ette
plumbing Note:
stack from The Existing Conditions
RENDER WCs over Documented are compiled
existing REFIT REFIT REFIT REFIT NEW EXISTING from External and Internal
masonary Surveys and some on site
wall
Tenancy 05 Tenancy 04 Tenancy 03 Tenancy 02 Tenancy 01 landscaping footpath measurements. Drawings may
- - - - AS EXISTING be inaccurate in some areas.
EXISTING
12515
FFL 22.270 FFL 22.390 garden bed
FFL 22.180 FFL 22.180 FFL 22.270
y
uring All
assumed assumed assumed
(not confirmed (not confirmed (not confirmed
NEW pivot
by surveyor) by surveyor) by surveyor)
hinged
Neighbo
entry door
EXISTING
& shopfront RAISE SILL
structural slab.
glazing of existing
TENANCY 01-05 DP100
assembly corner
02 TENANCY
floor finishes P1 EXISTING 02
window
A
197°49'00"
3.02 provided by sw pit 3.02
01-05
future tenant.
2.742
6.01 IL 22.09
W104
W501 D05 W401 D401 W301 D301 W201 D102 D101 W101
p.
W502 W402 W302 W202 W102
C-01 p. C-01 C-01 C-01 C-01
TBM: Screw in Kerb
A
w DP100
W503 W403 W303 W203 W103
2 "
2xP1 RL:22.44 AHD
74 '30
6
P1 DP100 P1 P1 P1 DP100 P1
.3
22
footpath
2. °23
RL
NEW fall
NEW concrete slab
3
facade framing CJ CJ CJ CJ
23
to conceal roof C-01 site boundary EXTENT of new
structure & box 286°44'20" 20.318 slab to be
'00"
gutter °58 discussed on-site
downpipes 268 742 with architect
garden garden 2.
footpath REMOVE NEW
EXISTING brick pavers
3.01
3.01
existing signage poles roof over
A
B
0 1 2 3 5
Scale 1 : 100 @ A3
po box 603 noosa heads qld 4567 project issue date details drawing proj no.
ph 07 5455 4808
commercial development T2 16/03/2022 for costing working drawings 2105
41 Sunshine Beach Road, Noosa Heads
email [email protected]
T1 10/03/2022 for costing
ground floor plan
abn 32 604 037 596 client scale date dwg no.
reg no 002195 BDH Group Investments Pty Ltd 1:100@A3 jan 2022 WD 2.01 T2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.