              7.2        Asset Protection Zones and Landscaping




              Figure 11. Components of an Asset Protection Zone (APZ)

              Asset protection zones provide the most strategically valuable defense against radiant heat and flame, and to
              a lesser extent embers. The relationship between radiant heat level and distance is not linear, as shown in
              Figure 9. The function of the Inner Protection Area (IPA) is to distance the Asset from Flame and Radiant
              Heat. The Outer Protection Area (OPA) separates ground fuels from canopy fuels, causing canopy fires to
              collapse and become ground fires.

              A minimum of 25m downslope of the dwelling shall be constructed and maintained as IPA.

              The IPA should be maintained as free as possible of available fuel, through short mowing of grass and
              removal of fine flammable debris. Plants retained in or introduced into the IPA should be selected based on
              low combustibility, by virtue of high moisture content, low volatile oil content, high leaf mineral levels, large
              fleshy leaves, absence of shedding bark. Plant arrangement is just as important as low combustibility. Plants
              should be placed so as to not provide either vertical or horizontal connectedness of plant material. Appendix
              1 provides examples of less hazardous plant species. Combustible vegetation shall not be allowed to come
              into contact with combustible parts of buildings. Trees shall not be allowed to directly overhang roof lines.

              The OPA should be maintained with low and minimal ground fuels, free of understorey or mid storey, and
              with separation of around 2 - 5m between tree canopies.

              In this instance the APZ for the structures shall be maintained as IPA.




               Report compiled by Bushfire Risk Reducers for Mr A. Wittaker, February 2023                 Page 18

Document Set ID: 24478325
                  23591412
Version: 1, Version Date: 19/01/2026
                          28/02/2025

Used in these records

About this file

File size
6.2 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Reference Document - Bushfire attack level assessment repor (As Published)t.pdf · 6.2 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.