Acoustic Report - Sunshine Beach Surf Club change MCU17-0024.01
• Class 1 Acoustic Calibrator, Norsonic Nor1256 (S/N 1256261123).
All instruments have current NATA calibrations. The source levels were measured before and after
the music testing to ensure that they did not vary significantly. In the instances where a source level
did very, the lower level has been used as the source level in the calculations to derive the allowable
source levels.
Table 3: Source music levels before and after testing
Source Level (dBC) @ 3m
Measurement
Zone/System Before
Location After Testing
Testing
A Reception/Foyer in-house distributed speaker system 86 87
B Gaming in-house distributed speaker system 90 89
C Main Bar Lounge in-house distributed speaker system 89 86
D Sports Bar in-house distributed speaker system 89 88
E Amenities in-house distributed speaker system 85 85
F Function Room in-house distributed speaker system 88 88
G Function Foyer & Amenities in-house distributed speaker system 87 87
H Ocean & Seaside Decks in-house distributed speaker system 88 88
I Main Bar Lounge stand-alone system 114 112
J Function Room stand-alone system 109 108
The doors and windows kept open and closed for the different test scenarios are identified in Figure
9 and Figure 10. For the all doors and windows closed scenarios the following doors were kept open
as per OLGR requirements:
• Main entry doors to the venue;
• Access doors from internal spaces to the outdoor Decks (two doors open);
• Access door to the DOSA;
• Internal door to the Gaming;
• Internal door to the Function Room.
When the southeast doors open scenario was tested, the southernmost sliding door from the Main
Bar Lounge to the Decks was closed, with the main entry door, DOSA door and northernmost door
to the Deck remaining open as well.
To provide balcony access from the Function Room, two doors along the eastern façade of the
building were opened. For the all doors and windows open scenario, the doors along the southeast
façade of the Function Room were open as well.
© SoundBASE Consulting Engineers Pty Ltd Sunshine Beach Surf Club
10 February 2020 Entertainment Noise Testing
19099-01-R01B-Entertainment Noise Test Report.docx Page 12
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.