Council archive · source document
Geotechnical Report_compressed · MCU22/0052
Douglas Partners Pty Ltd
ABN 75 053 980 117
www.douglaspartners.com.au
1/28 Kessling Avenue
Kunda Park QLD 4556
Phone (07) 5351 0400
Investigation Summary Report
Client Quentin Ellis Project No. 211008.01
Project Proposed Glamping Retreat Date 21 Dec 2022
Address 332 Eastern Branch Road, Kin Kin Doc No. R.001.docx
Introduction: This report presents the results of a geotechnical investigation undertaken by Douglas
Partners Pty Ltd (DP) for the proposed glamping retreat at 332 Eastern Branch Road, Kin Kin.
The investigation was undertaken at the request of Quentin Ellis in general accordance with DP’s
proposal 211008.01.P.001 dated 17 October 2022, following authorisation to proceed received
4 November 2022.
The aim of the investigation was to assess the following:
• subsurface conditions including groundwater;
• foundation soil reactivity in accordance with AS 2870 (2011);
• suitable high level footing options, allowable bearing pressures and estimated settlements;
• review of existing slope stability risks and impact of development (and other relevant works) with
reference to the Australian Geomechanics Society (AGS) guidelines; and
• recommendations on good practice measures to avoid or acceptably mitigate adverse instability.
The investigation comprised the drilling of five bores followed by laboratory testing. Details of the field
work and laboratory testing are presented in this report, together, with comments on the items listed
above.
This report must be read in conjunction with the attached notes entitled “About This Report” along with
any other attached explanatory notes and should be kept in its entirety without separation of individual
pages or sections.
Site Description: The site is located at 332 Eastern Branch Road, Kin Kin. The proposed glamping
retreat huts are to be located in the northern corner of the site (refer to Drawing 1 attached).
At the time of the investigation the site for the proposed glamping huts were located at the
convergence of a number of creek line gullies. The ground surface above the creek banks were
relatively flat and level, well covered with grass with mature trees scattered around the sites and along
the creek lines. The photograph in Figure 1 shows typical site conditions at the time of investigation.
Brisbane • Cairns • Canberra • Central Coast • Coffs Harbour • Darwin • Geelong • Gold Coast • Macarthur • Melbourne
FS 604853 Newcastle • North West Sydney • Perth • Port Macquarie • Sunshine Coast • Sydney • Townsville • Wollongong
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 39 pages
Page 2
Page 2 of 8 Figure 1: Viewing south towards creek line and Bore 3. Regional Geology: The Geological Survey of Queensland’s detailed surface geology mapping indicates the site is underlain by Quaternary aged flood plain alluvium described as typically comprising “Clay, silt, sand and gravel”. The alluvium is expected to be underlain by the Middle Triassic aged Kin Kin beds. The natural subsurface conditions encountered during the field work typically comprised silty clay, which are inferred to be alluvial for the upper part and then residual at depth, overlying weathered sandstone which is broadly consistent with the geology described above. Field Work Methods: The field work was undertaken on 11 November 2022, and comprised the drilling of five bores (designated as Bores 1 to 5) to between 3.0 m and 3.3 m depth. The bore locations were set out with reference to site features, with the locations and surface level recorded afterwards using a real-time DGPS device. The approximate bore locations are indicated on Drawing 1 attached. Proposed Glamping Retreat 211008.01.R.001.docx 332 Eastern Branch Road, Kin Kin Dec 2022
Page 3
Page 3 of 8 The bores were drilled with a 4WD ute mounted Jacro 200 drilling rig using continuous flight augers fitted with a tungsten carbide (TC) bit. Dynamic cone penetrometer (DCP) tests were undertaken adjacent to the bores, and pocket penetrometer (pp) tests were undertaken on auger cuttings, to provide an indication of the relative density and strength consistency of the subsurface soils. The field work was undertaken by experienced geotechnical personnel who logged the bores, collected samples for visual and tactile assessment and for subsequent laboratory testing. Strata identification was undertaken through observation of cutting returns and recovered samples. Field descriptions and samples were checked by a geotechnical engineer, and borehole logs corrected where appropriate to reflect the available laboratory test results. Field Work Results: The subsurface conditions encountered in the bores are given in detail on the attached borehole logs, together with notes defining the classification methods and descriptive terms used. The depths were measured below existing surface levels at the time of investigation. In summary, the subsurface conditions encountered in the bores typically comprised very stiff silty clay. The strength consistency of the silty clay was initially very stiff, grading very stiff to hard with depth locally. Groundwater seepage was observed at 2.6 m depth in Bore 5 only. No groundwater seepage was observed in any of the remaining bores whilst open at the time of drilling. It should be noted however, that groundwater depths and ground moisture conditions are affected by climatic conditions, soil permeability, drainage conditions and human influence; and will therefore vary with time. Laboratory Testing: Shrink-swell index tests were undertaken on ‘undisturbed’ tube samples recovered from the bores for classification purposes. The results of this testing are summarised in Table 1 with a material test report attached. Table 1: Results of Shrink-Swell Index Testing Bore Depth Material Shrinkage Swell Shrink-Swell Index No. (m) (%) (%) (% per ΔpF) 1 0.6-0.75 Silty CLAY 2.9 0.2 1.7 3 0.7-0.85 Silty CLAY 0.8 0.4 0.6 5 0.7-0.9 Silty CLAY 1.5 0.5 1.0 Proposed Glamping Retreat 211008.01.R.001.docx 332 Eastern Branch Road, Kin Kin Dec 2022
Page 4
Page 4 of 8 Comments: Site Classification Site classification of foundation soil reactivity strictly only applies to residential buildings up to two- storeys and to other buildings of similar size, loading and flexibility as defined in accordance with AS 2870. To provide an indication of the reactive surface movements associated with the site, the results of the laboratory testing were input into DP’s in-house program REACTIVE, to calculate the characteristic surface movement (ys) value in general accordance with AS 2870. AS 2870 provides recommended values of change in suction (Δu) and depth of suction (Hs) for major and regional centres throughout Australia. However, more detailed published data by Fox (2000) relating climatic conditions to suction was used for this report. A value of 1.2 pF was adopted for Δu and 1.5 m for Hs in the REACTIVE calculations. This is based on a “wet coastal” climatic zone. The results of the analysis indicate the ys value for the site in its current condition is estimated to be less than 20 mm, consistent with ‘Class S’ (slightly reactive) conditions. The designer will need to consider the effects of any earthworks on the site classification. Where existing site soils of similar reactivity won from excavation are reused as controlled fill, increased ground surface movements of up to 30 mm may result for a full clay fill profile, which is consistent with ‘Class M’ conditions. This is due to the need to consider “uncracked” conditions for the first five years after controlled fill placement or two years after excavation (where the depth of cut exceeds the lesser of 0.25 Hs or 0.5 m). If ‘abnormal’ soil moisture conditions are experienced at the site, the site classification would change to ‘Class P’ (problem site) which would require more extensive foundation works or could result in adverse foundation performance. ‘Abnormal’ soil moisture conditions are defined in AS 2870 (Clause 1.3.3) and in summary comprise: • Recent removal of buildings or structures likely to affect soil moisture conditions; • Unusual moisture caused by drains, channels, ponds, dams or tanks; • Recent removal of large trees; • Growth of trees too close to a structure; • Excessive or irregular watering of gardens adjacent to the structure; • Lack of maintenance of site drainage; • Failure to repair plumbing leaks. It should be noted that no assessment of the effect of soil moisture change by trees has been made in estimating the above ys values (either with respect to the removal of established trees prior to development of building pads, or the proximity of established or new trees to proposed buildings). Reference to the requirements in AS 2870 should be made by the building designer in this regard. It should be further noted that the presence or removal of trees can result in additional surface movement, due to tree-induced suction changes and tree-induced centre heave. Such tree-induced movement is not included in the ys calculations used to classify the site. Proposed Glamping Retreat 211008.01.R.001.docx 332 Eastern Branch Road, Kin Kin Dec 2022
Page 5
Page 5 of 8 The above site classification comments assume appropriate site maintenance to ensure suitable footing performance. A copy of QBCC notes about landscape planning and foundation maintenance is attached for information. Foundations It is anticipated that foundations for proposed structures would typically comprise high level footings founded into very stiff natural silty clay and may be designed for an allowable bearing pressure of 150 kPa. The above allowable bearing pressure is based on a factor of safety of 2.5 against bearing capacity failure. Slabs supported on high level foundations should be stiffened to suit the expected ground surface movements. All footing excavations should be inspected and tested by an experienced geotechnical engineer from DP to confirm bearing pressures prior to casting of concrete. Experience indicates that properly designed and constructed high level footings sized using the above allowable bearing pressure are likely to undergo settlements in the order of 1% of the footing width. Further advice should be sought from DP regarding settlements once actual footing configurations and design loads are known. Where footings are located adjacent to underground services, the footings should extend to below invert level for a distance of 1 m out from the trench. Beyond 1 m from the trench, the footings should be taken to below an imaginary line drawn up at 45 degrees from the invert level. These requirements do not override minimum structural footing base levels. Where necessary footings may be made up with mass concrete poured to the underside of footing, or alternatively constructed over excavated pedestals. Alternatively, where development loads exceed the above allowable bearing pressure and estimated settlements, a suitable deep foundation will be required. Bored piles would be considered suitable given the subsurface conditions encountered in the bores. The ultimate geotechnical strength (Rd,ug) of bored piles founding at least four pile diameters into the founding stratum can be calculated using the unfactored, ultimate shaft adhesion and end bearing values given in Table 2. The Rd,ug values given will need to be multiplied by a suitable geotechnical strength reduction factor (Øg) to obtain the design geotechnical strength (Rd,g) of piles. In accordance with AS 2159 (2009) the Øg value must be determined by the designer, but based on the anticipated site, design and installation risk factors, a Ø g value of 0.45 is considered likely for a low redundancy pile system. If working stress methods are used in the pile design, the Rd,ug values given in Table 2 will need to be divided by a factor of safety of 2.5 to calculate the maximum single pile working load. Proposed Glamping Retreat 211008.01.R.001.docx 332 Eastern Branch Road, Kin Kin Dec 2022
Page 6
Page 6 of 8
Table 2: Ultimate (Unfactored) Bored Pile Design Parameters
Material Ultimate Unfactored Ultimate Unfactored
Shaft Adhesion* End Bearing* (kPa)
(kPa)
Very stiff clays 45 600
Hard clays 60 1,200
Weathered sandstone 90 2,500
Notes: * Geotechnical strength reduction factor or factor of safety required
The upper 1 m of the bored pile shaft should be ignored in pile capacity estimates to allow for soil
shrinkage and load development.
Where there is lesser strength material within three pile diameters under pile toe levels, the bearing
pressure should be reduced to the value applicable to the lesser strength material.
Experience indicates that properly designed and constructed piles loaded as above are likely to
undergo settlements in the order of 1% of the pile diameter.
It is recommended that pile excavations be inspected by an experienced geotechnical engineer from
DP during drilling to ensure the design parameters adopted are suitable for the ground conditions and
to ensure that there is no soft or loose material remaining at the base or smear on the side wall of the
pile excavations.
Slope Stability Assessment
Noosa Shire Council’s Landslide Hazard Overlay is based on a number of factors which includes but
not limited to topography, regional geology and evidence of past instability. The site has been
identified as a high hazard area on the Landslide Hazard Overlay Map.
A site walk over inspection was undertaken as part of this slope stability risk assessment by a senior
geotechnical engineer from DP. The site walkover consisted of measurement of slope angles on site
along with observations of any previous slope instability activity on site and neighbouring areas.
The sites for the glamping huts were relatively flat and level located above the banks of the nearby
creek lines. No obvious signs or significant scarps, hummocks, visibly disturbed ground or tension
cracks were observed within or immediately surrounding the site which would usually indicate the
presence of past local or global instability.
A qualitative assessment of the likelihood, consequence and risk to the property has been carried out
based on the investigation results and DP’s experience from similar projects.
The terminology of the AGS Practice Note Guidelines for Landslide Risk Management (2007) has
been used in the description of hazards and the qualitative assessment of likelihood, consequence
and risk of slope instability. Terminology and risk matrix tables from the AGS Practice Note
Guidelines are attached.
Proposed Glamping Retreat 211008.01.R.001.docx
332 Eastern Branch Road, Kin Kin Dec 2022
Page 7
Page 7 of 8
Table 3: Slope Instability Risk Assessment for Property
Consequence to
Hazard Likelihood Risk to Property
Property
Scour and erosion of
Almost certain Insignificant Low
creek banks
Shallow rotational
Possible Insignificant Very Low
failure of creekbanks
Translational slide
following undercutting Rare Mine Very Low
toe of creekbank
Deep rotational failure Rare Minor Very Low
Minor scour and erosion of the steep creek banks could be expected under high velocity flows.
Maintenance and repair is assumed to be undertaken following flood events to prevent the
progression of scour. It is also recommended that glamping huts be set back a minimum distance of
5 m or equal to the vertical height of the creekbank (whichever is greater) away from the crest of the
creekbank.
Based on the results of the slope stability assessment, the site is assessed to be ‘very low’ to ‘low’ risk
of slope instability provided that development of the site is carried out in accordance with good
engineering practice for hillside developments. The AGS Guidelines suggest that a low level of risk is
usually “acceptable”.
A factor of safety of 1.5 against global stability must be adopted in the design of all engineered design
retaining walls.
References:
AGS. (2007). Practice Note Guidelines for Landslide Risk Management. Australian Geomechnics,
Volume 42, No 1: Australian Geomechanics Society, Landslide Taskforce, Landslide Practice Note
Working Group.
AS 2159. (2009). Piling - Design and Installation. Standards Australia.
AS 2870. (2011). Residential Slabs and Footings. Standards Australia.
Fox, E. (2000). A Climate-Based Design Depth of Moisture Change Map of Queensland and The Use
of Such Maps to Classify Sites Under AS 2870-1996. Australian Geomechanics Volume 3, Number 4,
53 to 60.
Limitations: Douglas Partners Pty Ltd (DP) has prepared this report for the proposed glamping
retreat at 332 Eastern Branch Road, Kin Kin in accordance with DP’s proposal dated 17 October
2022. The work was carried out under DP’s Conditions of Engagement. This report is provided for
the exclusive use of Quentin Ellis for this project only and for the purposes as described in the report.
It should not be used by or relied upon for other projects or purposes on the same or other site or by a
third party. Any party so relying upon this report beyond its exclusive use and purpose as stated
Proposed Glamping Retreat 211008.01.R.001.docx
332 Eastern Branch Road, Kin Kin Dec 2022
Page 8
Page 8 of 8
above, and without the express written consent of DP, does so entirely at its own risk and without
recourse to DP for any loss or damage. In preparing this report DP has necessarily relied upon
information provided by the client and/or their agents.
The results provided in the report are indicative of the sub-surface conditions on the site only at the
specific sampling and/or testing locations, and then only to the depths investigated and at the time the
work was carried out. Sub-surface conditions can change abruptly due to variable geological
processes and also as a result of human influences. Such changes may occur after DP’s field testing
has been completed.
DP’s advice is based upon the conditions encountered during this investigation. The accuracy of the
advice provided by DP in this report may be affected by undetected variations in ground conditions
across the site between and beyond the sampling and/or testing locations. The advice may also be
limited by budget constraints imposed by others or by site accessibility.
The assessment of atypical safety hazards arising from this advice is restricted to the geotechnical
components set out in this report and based on known project conditions and stated design advice
and assumptions. While some recommendations for safe controls may be provided, detailed ‘safety in
design’ assessment is outside the current scope of this report and requires additional project data and
assessment.
This report must be read in conjunction with all of the attached and should be kept in its entirety
without separation of individual pages or sections. DP cannot be held responsible for interpretations
or conclusions made by others unless they are supported by an expressed statement, interpretation,
outcome or conclusion stated in this report.
This report, or sections from this report, should not be used as part of a specification for a project,
without review and agreement by DP. This is because this report has been written as advice and
opinion rather than instructions for construction.
Douglas Partners Pty Ltd
Brett Egen (RPEQ 8597)
Senior Associate
Attachments: About this Report
Drawing 1 - Test Location Plan
Sampling Methods
Soil Descriptions
Rock Descriptions
Symbols & Abbreviations
Borehole Logs
Laboratory Test Results
AGS Guidelines
QBCC Notes
Proposed Glamping Retreat 211008.01.R.001.docx
332 Eastern Branch Road, Kin Kin Dec 2022
Page 9
Introduction • A localised, perched water table may lead to
These notes have been provided to amplify DP's an erroneous indication of the true water
report in regard to classification methods, field table;
procedures and the comments section. Not all are • Water table levels will vary from time to time
necessarily relevant to all reports. with seasons or recent weather changes.
They may not be the same at the time of
DP's reports are based on information gained from construction as are indicated in the report;
limited subsurface excavations and sampling, and
supplemented by knowledge of local geology and • The use of water or mud as a drilling fluid will
experience. For this reason, they must be mask any groundwater inflow. Water has to
regarded as interpretive rather than factual be blown out of the hole and drilling mud must
documents, limited to some extent by the scope of first be washed out of the hole if water
information on which they rely. measurements are to be made.
More reliable measurements can be made by
Copyright installing standpipes which are read at intervals
This report is the property of Douglas Partners Pty over several days, or perhaps weeks for low
Ltd. The report may only be used for the purpose permeability soils. Piezometers, sealed in a
for which it was commissioned and in accordance particular stratum, may be advisable in low
with the Conditions of Engagement for the permeability soils or where there may be
commission supplied at the time of proposal. interference from a perched water table.
Unauthorised use of this report in any form
whatsoever is prohibited.
Reports
The report has been prepared by qualified
Borehole and Test Pit Logs personnel, is based on the information obtained
The borehole and test pit logs presented in this from field and laboratory testing, and has been
report are an engineering and/or geological undertaken to current engineering standards of
interpretation of the subsurface conditions, and interpretation and analysis. Where the report has
their reliability will depend to some extent on been prepared for a specific design proposal, the
frequency of sampling and the method of drilling or information and interpretation may not be relevant
excavation. Ideally, continuous undisturbed if the design proposal is changed. If this happens,
sampling or core drilling will provide the most DP will be pleased to review the report and the
reliable assessment, but this is not always sufficiency of the investigation work.
practicable or possible to justify on economic
grounds. In any case the boreholes and test pits Every care is taken with the report as it relates to
represent only a very small sample of the total interpretation of subsurface conditions, discussion
subsurface profile. of geotechnical and environmental aspects, and
recommendations or suggestions for design and
Interpretation of the information and its application construction. However, DP cannot always
to design and construction should therefore take anticipate or assume responsibility for:
into account the spacing of boreholes or pits, the • Unexpected variations in ground conditions.
frequency of sampling, and the possibility of other The potential for this will depend partly on
than 'straight line' variations between the test borehole or pit spacing and sampling
locations. frequency;
• Changes in policy or interpretations of policy
by statutory authorities; or
• The actions of contractors responding to
Groundwater
commercial pressures.
Where groundwater levels are measured in
If these occur, DP will be pleased to assist with
boreholes there are several potential problems,
investigations or advice to resolve the matter.
namely:
• In low permeability soils groundwater may
enter the hole very slowly or perhaps not at all
during the time the hole is left open;
July 2010
Page 10
Site Anomalies
In the event that conditions encountered on site
during construction appear to vary from those
which were expected from the information
contained in the report, DP requests that it be
immediately notified. Most problems are much
more readily resolved when conditions are
exposed rather than at some later stage, well after
the event.
Information for Contractual Purposes
Where information obtained from this report is
provided for tendering purposes, it is
recommended that all information, including the
written report and discussion, be made available.
In circumstances where the discussion or
comments section is not relevant to the contractual
situation, it may be appropriate to prepare a
specially edited document. DP would be pleased
to assist in this regard and/or to make additional
report copies available for contract purposes at a
nominal charge.
Site Inspection
The company will always be pleased to provide
engineering inspection services for geotechnical
and environmental aspects of work to which this
report is related. This could range from a site visit
to confirm that conditions exposed are as
expected, to full time engineering presence on
site.
July 2010
Page 11
5
1 4
3
Site
2
Location Plan
N
LEGEND:-
Bore Location and Number
NOTE:-
1. Test locations are approximate only and are
shown with reference to existing site features.
2. Image obtained from Gogle Earth Pro.
CLIENT: Quentin Ellis
TITLE: Test Location Plan PROJECT No: 211008.01
Douglas Partners
Geotechnics Environment Groundwater
OFFICE: Sunshine Coast DRAWN BY: JST Proposed Glamping Retreat DRAWING No: 1
SCALE: As shown DATE: November 2022 332 Eastern Branch Road, Kin Kin REVISION: 0
Page 12
Sampling reliability, due to the remoulding, possible mixing
Sampling is carried out during drilling or test pitting or softening of samples by groundwater.
to allow engineering examination (and laboratory
testing where required) of the soil or rock.
Non-core Rotary Drilling
Disturbed samples taken during drilling provide The borehole is advanced using a rotary bit, with
information on colour, type, inclusions and, water or drilling mud being pumped down the drill
depending upon the degree of disturbance, some rods and returned up the annulus, carrying the drill
information on strength and structure. cuttings. Only major changes in stratification can
be determined from the cuttings, together with
Undisturbed samples are taken by pushing a thin- some information from the rate of penetration.
walled sample tube into the soil and withdrawing it Where drilling mud is used this can mask the
to obtain a sample of the soil in a relatively cuttings and reliable identification is only possible
undisturbed state. Such samples yield information from separate sampling such as SPTs.
on structure and strength, and are necessary for
laboratory determination of shear strength and
compressibility. Undisturbed sampling is generally Continuous Core Drilling
effective only in cohesive soils. A continuous core sample can be obtained using a
diamond tipped core barrel, usually with a 50 mm
internal diameter. Provided full core recovery is
Test Pits achieved (which is not always possible in weak
Test pits are usually excavated with a backhoe or rocks and granular soils), this technique provides a
an excavator, allowing close examination of the in- very reliable method of investigation.
situ soil if it is safe to enter into the pit. The depth
of excavation is limited to about 3 m for a backhoe
and up to 6 m for a large excavator. A potential Standard Penetration Tests
disadvantage of this investigation method is the Standard penetration tests (SPT) are used as a
larger area of disturbance to the site. means of estimating the density or strength of soils
and also of obtaining a relatively undisturbed
sample. The test procedure is described in
Large Diameter Augers Australian Standard 1289, Methods of Testing
Boreholes can be drilled using a rotating plate or Soils for Engineering Purposes - Test 6.3.1.
short spiral auger, generally 300 mm or larger in
diameter commonly mounted on a standard piling The test is carried out in a borehole by driving a 50
rig. The cuttings are returned to the surface at mm diameter split sample tube under the impact of
intervals (generally not more than 0.5 m) and are a 63 kg hammer with a free fall of 760 mm. It is
disturbed but usually unchanged in moisture normal for the tube to be driven in three
content. Identification of soil strata is generally successive 150 mm increments and the 'N' value
much more reliable than with continuous spiral is taken as the number of blows for the last 300
flight augers, and is usually supplemented by mm. In dense sands, very hard clays or weak
occasional undisturbed tube samples. rock, the full 450 mm penetration may not be
practicable and the test is discontinued.
Continuous Spiral Flight Augers The test results are reported in the following form.
The borehole is advanced using 90-115 mm • In the case where full penetration is obtained
diameter continuous spiral flight augers which are with successive blow counts for each 150 mm
withdrawn at intervals to allow sampling or in-situ of, say, 4, 6 and 7 as:
testing. This is a relatively economical means of 4,6,7
drilling in clays and sands above the water table. N=13
Samples are returned to the surface, or may be • In the case where the test is discontinued
collected after withdrawal of the auger flights, but before the full penetration depth, say after 15
they are disturbed and may be mixed with soils blows for the first 150 mm and 30 blows for
from the sides of the hole. Information from the the next 40 mm as:
drilling (as distinct from specific sampling by SPTs 15, 30/40 mm
or undisturbed samples) is of relatively low
July 2010
Page 13
The results of the SPT tests can be related
empirically to the engineering properties of the
soils.
Dynamic Cone Penetrometer Tests /
Perth Sand Penetrometer Tests
Dynamic penetrometer tests (DCP or PSP) are
carried out by driving a steel rod into the ground
using a standard weight of hammer falling a
specified distance. As the rod penetrates the soil
the number of blows required to penetrate each
successive 150 mm depth are recorded. Normally
there is a depth limitation of 1.2 m, but this may be
extended in certain conditions by the use of
extension rods. Two types of penetrometer are
commonly used.
• Perth sand penetrometer - a 16 mm diameter
flat ended rod is driven using a 9 kg hammer
dropping 600 mm (AS 1289, Test 6.3.3). This
test was developed for testing the density of
sands and is mainly used in granular soils and
filling.
• Cone penetrometer - a 16 mm diameter rod
with a 20 mm diameter cone end is driven
using a 9 kg hammer dropping 510 mm (AS
1289, Test 6.3.2). This test was developed
initially for pavement subgrade investigations,
and correlations of the test results with
California Bearing Ratio have been published
by various road authorities.
July 2010
Page 14
Description and Classification Methods
The methods of description and classification of The proportions of secondary constituents of soils
soils and rocks used in this report are generally are described as follows:
based on Australian Standard AS1726:2017, In fine grained soils (>35% fines)
Geotechnical Site Investigations. In general, the
Term Proportion Example
descriptions include strength or density, colour,
of sand or
structure, soil or rock type and inclusions.
gravel
And Specify Clay (60%) and
Soil Types
Sand (40%)
Soil types are described according to the
predominant particle size, qualified by the grading Adjective >30% Sandy Clay
of other particles present: With 15 – 30% Clay with sand
Trace 0 - 15% Clay with trace
Type Particle size (mm) sand
Boulder >200
Cobble 63 - 200 In coarse grained soils (>65% coarse)
- with clays or silts
Gravel 2.36 - 63
Term Proportion Example
Sand 0.075 - 2.36
of fines
Silt 0.002 - 0.075
And Specify Sand (70%) and
Clay <0.002 Clay (30%)
Adjective >12% Clayey Sand
The sand and gravel sizes can be further
With 5 - 12% Sand with clay
subdivided as follows:
Trace 0 - 5% Sand with trace
Type Particle size (mm) clay
Coarse gravel 19 - 63
In coarse grained soils (>65% coarse)
Medium gravel 6.7 - 19 - with coarser fraction
Fine gravel 2.36 – 6.7 Term Proportion Example
Coarse sand 0.6 - 2.36 of coarser
Medium sand 0.21 - 0.6 fraction
Fine sand 0.075 - 0.21 And Specify Sand (60%) and
Gravel (40%)
Adjective >30% Gravelly Sand
Definitions of grading terms used are: With 15 - 30% Sand with gravel
Well graded - a good representation of all Trace 0 - 15% Sand with trace
particle sizes gravel
Poorly graded - an excess or deficiency of
particular sizes within the specified range The presence of cobbles and boulders shall be
Uniformly graded - an excess of a particular specifically noted by beginning the description with
particle size ‘Mix of Soil and Cobbles/Boulders’ with the word
Gap graded - a deficiency of a particular order indicating the dominant first and the
particle size with the range proportion of cobbles and boulders described
together.
May 2019
Page 15
Cohesive Soils Estuarine soil – deposited in coastal estuaries;
Cohesive soils, such as clays, are classified on the Marine soil – deposited in a marine
basis of undrained shear strength. The strength environment;
may be measured by laboratory testing, or Lacustrine soil – deposited in freshwater
estimated by field tests or engineering lakes;
examination. The strength terms are defined as
follows: Aeolian soil – carried and deposited by wind;
Colluvial soil – soil and rock debris
Undrained transported down slopes by gravity;
Description Abbreviation
shear strength Topsoil – mantle of surface soil, often with
(kPa) high levels of organic material.
Very soft VS <12
Fill – any material which has been moved by
Soft S 12 - 25 man.
Firm F 25 - 50
Stiff St 50 - 100
Very stiff VSt 100 - 200 Moisture Condition – Coarse Grained Soils
Hard H >200 For coarse grained soils the moisture condition
Friable Fr - should be described by appearance and feel using
the following terms:
Dry (D) Non-cohesive and free-running.
Cohesionless Soils Moist (M) Soil feels cool, darkened in
Cohesionless soils, such as clean sands, are colour.
classified on the basis of relative density, generally Soil tends to stick together.
from the results of standard penetration tests Sand forms weak ball but breaks
(SPT), cone penetration tests (CPT) or dynamic
easily.
penetrometers (PSP). The relative density terms
are given below: Wet (W) Soil feels cool, darkened in
colour.
Relative Abbreviation Density Index Soil tends to stick together, free
Density (%) water forms when handling.
Very loose VL <15
Loose L 15-35
Medium dense MD 35-65 Moisture Condition – Fine Grained Soils
Dense D 65-85 For fine grained soils the assessment of moisture
content is relative to their plastic limit or liquid limit,
Very dense VD >85 as follows:
‘Moist, dry of plastic limit’ or ‘w <PL’ (i.e. hard
and friable or powdery).
Soil Origin
‘Moist, near plastic limit’ or ‘w ≈ PL (i.e. soil can
It is often difficult to accurately determine the origin
be moulded at moisture content approximately
of a soil. Soils can generally be classified as:
equal to the plastic limit).
Residual soil - derived from in-situ weathering
‘Moist, wet of plastic limit’ or ‘w >PL’ (i.e. soils
of the underlying rock;
usually weakened and free water forms on the
Extremely weathered material – formed from hands when handling).
in-situ weathering of geological formations.
‘Wet’ or ‘w ≈LL’ (i.e. near the liquid limit).
Has soil strength but retains the structure or
fabric of the parent rock; ‘Wet’ or ‘w >LL’ (i.e. wet of the liquid limit).
Alluvial soil – deposited by streams and rivers;
May 2019
Page 16
Rock Strength
Rock strength is defined by the Unconfined Compressive Strength and it refers to the strength of the rock
substance and not the strength of the overall rock mass, which may be considerably weaker due to defects.
The Point Load Strength Index Is(50) is commonly used to provide an estimate of the rock strength and site
specific correlations should be developed to allow UCS values to be determined. The point load strength
test procedure is described by Australian Standard AS4133.4.1-2007. The terms used to describe rock
strength are as follows:
Strength Term Abbreviation Unconfined Compressive Point Load Index *
Strength MPa Is(50) MPa
Very low VL 0.6 - 2 0.03 - 0.1
Low L 2-6 0.1 - 0.3
Medium M 6 - 20 0.3 - 1.0
High H 20 - 60 1-3
Very high VH 60 - 200 3 - 10
Extremely high EH >200 >10
* Assumes a ratio of 20:1 for UCS to Is (50). It should be noted that the UCS to Is(50) ratio varies significantly
for different rock types and specific ratios should be determined for each site.
Degree of Weathering
The degree of weathering of rock is classified as follows:
Term Abbreviation Description
Residual Soil RS Material is weathered to such an extent that it has soil
properties. Mass structure and material texture and fabric
of original rock are no longer visible, but the soil has not
been significantly transported.
Extremely weathered XW Material is weathered to such an extent that it has soil
properties. Mass structure and material texture and fabric
of original rock are still visible
Highly weathered HW The whole of the rock material is discoloured, usually by
iron staining or bleaching to the extent that the colour of the
original rock is not recognisable. Rock strength is
significantly changed by weathering. Some primary
minerals have weathered to clay minerals. Porosity may be
increased by leaching, or may be decreased due to
deposition of weathering products in pores.
Moderately MW The whole of the rock material is discoloured , usually by
weathered iron staining or bleaching to the extent that the colour of the
original rock is not recognisable, but shows little or no
change of strength from fresh rock.
Slightly weathered SW Rock is partially discoloured with staining or bleaching
along joints but shows little or no change of strength from
fresh rock.
Fresh FR No signs of decomposition or staining.
Note: If HW and MW cannot be differentiated use DW (see below)
Distinctly weathered DW Rock strength usually changed by weathering. The rock
may be highly discoloured, usually by iron staining.
Porosity may be increased by leaching or may be
decreased due to deposition of weathered products in
pores.
November 2021
Page 17
Introduction
These notes summarise abbreviations commonly Orientation
used on borehole logs and test pit reports. The inclination of defects is always measured from
the perpendicular to the core axis.
Drilling or Excavation Methods h horizontal
C Core drilling v vertical
R Rotary drilling sh sub-horizontal
SFA Spiral flight augers sv sub-vertical
NMLC Diamond core - 52 mm dia
NQ Diamond core - 47 mm dia
HQ Diamond core - 63 mm dia Coating or Infilling Term
PQ Diamond core - 81 mm dia cln clean
co coating
he healed
Water inf infilled
Water seep stn stained
Water level ti tight
vn veneer
Sampling and Testing
Coating Descriptor
A Auger sample
ca calcite
B Bulk sample
cbs carbonaceous
D Disturbed sample
cly clay
E Environmental sample
fe iron oxide
U50 Undisturbed tube sample (50mm)
mn manganese
W Water sample
slt silty
pp Pocket penetrometer (kPa)
PID Photo ionisation detector
PL Point load strength Is(50) MPa
Shape
S Standard Penetration Test
cu curved
V Shear vane (kPa)
ir irregular
pl planar
st stepped
Description of Defects in Rock un undulating
The abbreviated descriptions of the defects should
be in the following order: Depth, Type, Orientation,
Coating, Shape, Roughness and Other. Drilling
and handling breaks are not usually included on Roughness
the logs. po polished
ro rough
Defect Type sl slickensided
B Bedding plane sm smooth
Cs Clay seam vr very rough
Cv Cleavage
Cz Crushed zone
Ds Decomposed seam
F Fault Other
J Joint fg fragmented
Lam Lamination bnd band
Pt Parting qtz quartz
Sz Sheared Zone
V Vein
May 2017
Page 18
Graphic Symbols for Soil and Rock
General Sedimentary Rocks
Asphalt Boulder conglomerate
Road base Conglomerate
Concrete Conglomeratic sandstone
Filling Sandstone
Soils Siltstone
Topsoil Laminite
Peat Mudstone, claystone, shale
Clay Coal
Silty clay Limestone
Sandy clay Metamorphic Rocks
Gravelly clay Slate, phyllite, schist
Shaly clay Gneiss
Silt Quartzite
Clayey silt
Igneous Rocks
Sandy silt Granite
Sand Dolerite, basalt, andesite
Clayey sand Dacite, epidote
Silty sand Tuff, breccia
Gravel Porphyry
Sandy gravel
Cobbles, boulders
Talus
May 2017
Page 19
BOREHOLE LOG
CLIENT: Quentin Ellis SURFACE LEVEL: 83.8 AHD BORE No: 1
PROJECT: Proposed Glamping Retreat EASTING: 488904.3 PROJECT No: 211008.01
LOCATION: 332 Eastern Branch Road, Kin Kin NORTHING: 7091366.4 DATE: 11/11/2022
DIP/AZIMUTH: 90°/-- SHEET 1 OF 1
Description Sampling & In Situ Testing
Graphic
Dynamic Penetrometer Test
Water
Depth
Log
RL
Sample
of (blows per 100mm)
Depth
Type
(m) Results &
Comments
Strata 5 10 15 20
Silty CLAY CI-CH: medium to high plasticity,
orange-brown, with fine trace of medium to coarse grained
sand, moist, very stiff
0.3 pp = 350
0.6 pp = 380
- orange-brown mottled grey, trace of fine to medium
U50 pp >600
gravel
83
0.9 pp = 410
0.95 0.95
1 Silty CLAY CL-CI: low to medium plasticity, orange-brown 1
mottled grey, with fine trace of medium to coarse grained
sand, trace of fine to medium gravel, moist, very stiff to
hard
1.4 pp = 420
82
- orange-brown mottled brown, hard
1.9 pp >600
2 2
2.4 pp >600
2.5
D
81
2.9 pp >600
3 3.0 3.0 3
Bore discontinued at 3.0m
Limit of Investigation
80
RIG: Jacro 200 DRILLER: JB LOGGED: JB CASING: Nil
TYPE OF BORING: Auger
WATER OBSERVATIONS: No groundwater seepage observed at time of drilling.
REMARKS: Location coordinates are in MGA94 Zone 56J. Sand Penetrometer AS1289.6.3.3
Cone Penetrometer AS1289.6.3.2
SAMPLING & IN SITU TESTING LEGEND
A Auger sample G Gas sample PID Photo ionisation detector (ppm)
B Bulk sample P Piston sample PL(A) Point load axial test Is(50) (MPa)
BLK Block sample Ux Tube sample (x mm dia.) PL(D) Point load diametral test Is(50) (MPa)
C Core drilling W Water sample pp Pocket penetrometer (kPa)
D Disturbed sample Water seep S Standard penetration test
E Environmental sample Water level V Shear vane (kPa)
Page 20
BOREHOLE LOG
CLIENT: Quentin Ellis SURFACE LEVEL: 83.6 AHD BORE No: 2
PROJECT: Proposed Glamping Retreat EASTING: 488906.3 PROJECT No: 211008.01
LOCATION: 332 Eastern Branch Road, Kin Kin NORTHING: 7091358.9 DATE: 11/11/2022
DIP/AZIMUTH: 90°/-- SHEET 1 OF 1
Description Sampling & In Situ Testing
Graphic
Dynamic Penetrometer Test
Water
Depth
Log
RL
Sample
of (blows per 100mm)
Depth
Type
(m) Results &
Comments
Strata 5 10 15 20
Silty CLAY CI: medium plasticity, orange-brown, with fine
trace of medium to coarse grained sand, moist, very stiff
0.3 pp = 410
0.6 pp = 480
83
- fine to medium gravel
0.9 pp >600
1 1
1.2
Silty CLAY CL-CI: low to medium plasticity, orange-brown
mottled grey, with fine trace of medium to coarse grained
sand, fine to medium gravel, moist, very stiff to hard
1.4 pp >600
82
1.9 pp >600
2 2
2.4 pp >600
2.5
Silty CLAY CL: low plasticity, orange-brown mottled
brown, with fine trace of medium to coarse grained sand,
81
fine to medium gravel, moist, hard
2.9 pp >600
3 3.0 3
Bore discontinued at 3.0m
Limit of Investigation
80
RIG: Jacro 200 DRILLER: JB LOGGED: JB CASING: Nil
TYPE OF BORING: Auger
WATER OBSERVATIONS: No groundwater seepage observed at time of drilling.
REMARKS: Location coordinates are in MGA94 Zone 56J. Sand Penetrometer AS1289.6.3.3
Cone Penetrometer AS1289.6.3.2
SAMPLING & IN SITU TESTING LEGEND
A Auger sample G Gas sample PID Photo ionisation detector (ppm)
B Bulk sample P Piston sample PL(A) Point load axial test Is(50) (MPa)
BLK Block sample Ux Tube sample (x mm dia.) PL(D) Point load diametral test Is(50) (MPa)
C Core drilling W Water sample pp Pocket penetrometer (kPa)
D Disturbed sample Water seep S Standard penetration test
E Environmental sample Water level V Shear vane (kPa)
Page 21
BOREHOLE LOG
CLIENT: Quentin Ellis SURFACE LEVEL: 82.6 AHD BORE No: 3
PROJECT: Proposed Glamping Retreat EASTING: 488933.4 PROJECT No: 211008.01
LOCATION: 332 Eastern Branch Road, Kin Kin NORTHING: 7091374.7 DATE: 11/11/2022
DIP/AZIMUTH: 90°/-- SHEET 1 OF 1
Description Sampling & In Situ Testing
Graphic
Dynamic Penetrometer Test
Water
Depth
Log
RL
Sample
of (blows per 100mm)
Depth
Type
(m) Results &
Comments
Strata 5 10 15 20
Silty CLAY CI-CH: medium to high plasticity,
orange-brown mottled brown, with fine trace of medium to
coarse grained sand, trace of fine to medium gravel,
moist, very stiff
0.4 pp = 450
0.5
0.6 pp = 470
82
U50 pp >600
0.85
0.9 pp >600
1 1
1.3
Silty CLAY CL: low plasticity, orange-brown mottled
brown, with fine trace of medium to coarse grained sand, 1.4 pp >600
trace of fine to medium gravel, trace of cobbles, moist,
very stiff to hard
81
1.9 pp >600
>>
2 2
2.4 pp >600
80
- orange-brown mottled grey, hard
2.9 pp >600
3 3.0 3
Bore discontinued at 3.0m
Limit of Investigation
79
RIG: Jacro 200 DRILLER: JB LOGGED: JB CASING: Nil
TYPE OF BORING: Auger
WATER OBSERVATIONS: No groundwater seepage observed at time of drilling.
REMARKS: Location coordinates are in MGA94 Zone 56J. Sand Penetrometer AS1289.6.3.3
Cone Penetrometer AS1289.6.3.2
SAMPLING & IN SITU TESTING LEGEND
A Auger sample G Gas sample PID Photo ionisation detector (ppm)
B Bulk sample P Piston sample PL(A) Point load axial test Is(50) (MPa)
BLK Block sample Ux Tube sample (x mm dia.) PL(D) Point load diametral test Is(50) (MPa)
C Core drilling W Water sample pp Pocket penetrometer (kPa)
D Disturbed sample Water seep S Standard penetration test
E Environmental sample Water level V Shear vane (kPa)
Page 22
BOREHOLE LOG
CLIENT: Quentin Ellis SURFACE LEVEL: 81.0 AHD BORE No: 4
PROJECT: Proposed Glamping Retreat EASTING: 488965.9 PROJECT No: 211008.01
LOCATION: 332 Eastern Branch Road, Kin Kin NORTHING: 7091378.7 DATE: 11/11/2022
DIP/AZIMUTH: 90°/-- SHEET 1 OF 1
Description Sampling & In Situ Testing
Graphic
Dynamic Penetrometer Test
Water
Depth
Log
RL
Sample
of (blows per 100mm)
Depth
Type
(m) Results &
Comments
Strata 5 10 15 20
81
Silty CLAY CL-CI: low to medium plasticity, orange-brown,
with fine trace of medium to coarse grained sand, moist,
very stiff
0.3 pp = 420
0.6 pp = 430
0.9 pp >600
1 1
80
1.3
Silty CLAY CL: low plasticity, orange-brown mottled
brown, with fine trace of medium to coarse grained sand, 1.4 pp >600
trace of fine to coarse gravel, trace of cobbles, moist, very
stiff to hard
1.8
Silty CLAY CI: medium plasticity, grey mottled
orange-brown, with fine trace of medium to coarse grained 1.9 pp = 330
sand, trace of fine gravel, trace of cobbles, moist, very stiff
2 2
79
2.2 2.2
Silty CLAY CI-CH: medium to high plasticity, grey mottled
orange-brown, with fine trace of medium to coarse grained
sand, trace of fine gravel, trace of cobbles, moist, very stiff D
2.4 pp = 320
2.5
2.9 pp = 330
3 3.0 3
78
Bore discontinued at 3.0m
Limit of Investigation
RIG: Jacro 200 DRILLER: JB LOGGED: JB CASING: Nil
TYPE OF BORING: Auger
WATER OBSERVATIONS: No groundwater seepage observed at time of drilling.
REMARKS: Location coordinates are in MGA94 Zone 56J. Sand Penetrometer AS1289.6.3.3
Cone Penetrometer AS1289.6.3.2
SAMPLING & IN SITU TESTING LEGEND
A Auger sample G Gas sample PID Photo ionisation detector (ppm)
B Bulk sample P Piston sample PL(A) Point load axial test Is(50) (MPa)
BLK Block sample Ux Tube sample (x mm dia.) PL(D) Point load diametral test Is(50) (MPa)
C Core drilling W Water sample pp Pocket penetrometer (kPa)
D Disturbed sample Water seep S Standard penetration test
E Environmental sample Water level V Shear vane (kPa)
Page 23
BOREHOLE LOG
CLIENT: Quentin Ellis SURFACE LEVEL: 79.1 AHD BORE No: 5
PROJECT: Proposed Glamping Retreat EASTING: 488963.4 PROJECT No: 211008.01
LOCATION: 332 Eastern Branch Road, Kin Kin NORTHING: 7091421.6 DATE: 11/11/2022
DIP/AZIMUTH: 90°/-- SHEET 1 OF 1
Description Sampling & In Situ Testing
Graphic
Dynamic Penetrometer Test
Water
Depth
Log
RL
Sample
of (blows per 100mm)
Depth
Type
(m) Results &
Comments
Strata 5 10 15 20
Silty CLAY CL: low plasticity, orange-brown, with fine
trace of medium to coarse grained sand, moist, very stiff
79
0.3 pp = 250
0.35
Silty CLAY CI: medium plasticity, orange-brown, with fine
trace of medium to coarse grained sand, trace of fine to
coarse gravel, moist, very stiff
- orange-brown mottled brown-grey, trace of cobbles 0.6 pp = 300
0.7
U50 pp >600
0.9 pp = 350
1 1
78
- orange-brown mottled brown, trace of fine gravel
1.4 pp = 280
1.8
Silty CLAY CI-CH: medium to high plasticity,
orange-brown mottled brown-grey, with fine trace of 1.9 pp = 250
medium to coarse grained sand, trace of fine to coarse
2 gravel, trace of cobbles, moist, very stiff 2
77
2.4 pp = 330
- wet
2.9 pp = 200
3 3
3.1
76
SANDSTONE/SILTSTONE HW: grey, very low strength,
highly weathered
3.3
Bore discontinued at 3.3m
Limit of Investigation
RIG: Jacro 200 DRILLER: JB LOGGED: JB CASING: Nil
TYPE OF BORING: Auger
WATER OBSERVATIONS: Groundawter seepage observed at 2.6m depth.
REMARKS: Location coordinates are in MGA94 Zone 56J. Sand Penetrometer AS1289.6.3.3
Cone Penetrometer AS1289.6.3.2
SAMPLING & IN SITU TESTING LEGEND
A Auger sample G Gas sample PID Photo ionisation detector (ppm)
B Bulk sample P Piston sample PL(A) Point load axial test Is(50) (MPa)
BLK Block sample Ux Tube sample (x mm dia.) PL(D) Point load diametral test Is(50) (MPa)
C Core drilling W Water sample pp Pocket penetrometer (kPa)
D Disturbed sample Water seep S Standard penetration test
E Environmental sample Water level V Shear vane (kPa)
Page 24
Material Test Report
Report Number: 211008.01-1 Douglas Partners Pty Ltd
Sunshine Coast Laboratory
Issue Number: 1
1/28 Kessling Avenue Kunda Park QLD 4556
Date Issued: 17/11/2022
Phone: (07) 5351 0400
Client: Quentin Ellis
Email: [email protected]
, Noosa Heads QLD 4567
Contact: Quentin Ellis
Project Number: 211008.01
Project Name: Proposed Glamping Retreat
Project Location: 332 Eastern Branch Road, Kin Kin QLD
Work Request: 20857 Accredited for compliance with ISO/IEC 17025 - Testing
Date Sampled: 11/11/2022
Dates Tested: 14/11/2022 - 15/11/2022
Sampling Method: Sampled by Engineering Department
Approved Signatory: Martin Cook
The results apply to the sample as received
Assistant Laboratory Manager
Laboratory Accreditation Number: 828
Shrink Swell Index AS 1289 7.1.1 & 2.1.1
Sample Number SS-20857A SS-20857B SS-20857C
Date Sampled 11/11/2022 11/11/2022 11/11/2022
Date Tested 15/11/2022 15/11/2022 15/11/2022
Material Source Insitu Insitu Insitu
Sample Location Bore 1 Bore 3 Bore 5
(0.6 - 0.75 m) (0.7 - 0.85 m) (0.7 - 0.9 m)
Inert Material Estimate (%) 5 5 8
Pocket Penetrometer before (kPa) >600 >600 >600
Pocket Penetrometer after (kPa) 450 480 350
Shrinkage Moisture Content (%) 24.8 18.5 19.9
Shrinkage (%) 2.9 0.8 1.5
Swell Moisture Content Before (%) 28.8 20.1 17.9
Swell Moisture Content After (%) 30.3 26.9 26.6
Swell (%) 0.2 0.4 0.5
Shrink Swell Index Iss (%) 1.7 0.6 1.0
Visual Description ** ** **
Cracking SC SC UC
Crumbling No No No
Remarks ** ** **
Shrink Swell Index (Iss) reported as the percentage vertical strain per pF change in suction.
Cracking Terminology: UC Uncracked, SC Slightly Cracked, MC Moderately Cracked, HC Highly Cracked, FR Fragmented.
NATA Accreditation does not cover the performance of pocket penetrometer readings.
Report Number: 211008.01-1 This document shall not be reproduced except in full without approval of the laboratory. Page 1 of 1
Results relate only to the items tested/sampled.
Page 25
A guide to preventing structural damage Build better.
Page 26
Home owners guide to planning landscaping and maintenance of foundations Structural damage can result from - under normal conditions. The movement in clay soils caused by performance of footings under this varying moisture conditions around the standard requires normal conditions to perimeter of homes. be maintained around the house. The majority of Queensland homes This guideline identifies abnormal are situated on what are termed conditions that should be avoided reactive clay soils. These soils are and/or corrected. subject to expansion and contraction Dry seasons cause soils to dry out depending on seasonal weather and rapidly. Wet seasons cause soils to site conditions. Sandy sites and rocky become wet quickly. This results in terrain are usually not prone to this sudden extreme volume changes and expansion and contraction. movement in soil. In Queensland, engineers design Abnormal conditions (other than footings to the Australian Standard seasonal changes), may include the AS2870 – 2011 Residential slabs effect of trees, poor surface drainage and footings. Footings correctly and/or leaking plumbing. If not allowed designed to this standard are intended for in the engineer’s design, these to accommodate the expected types of abnormal conditions may lead movements caused by seasonal to movement and damage varying volume changes in the soil (swelling from minor to extreme. when wet and shrinking when dry) NORMAL MOVEMENT EXPECTATIONS FOR BUILDINGS CONSTUCTED ON REACTIVE CLAY SOILS
Page 27
How much can the soils under my
house move?
The amount of movement that may occur depends on the site classification,
which is defined under the Australian Standard AS2870.
The relevant classifications and expected movements under normal site
conditions and seasonal influences are:
Site Description of type of clay and reactivity Expected range of
classification movement
A Mostly sand and rock with little or no ground movement 0
from moisture changes.
S Slightly reactive clays that do not present significant 0 to 20mm
trouble. Very limited damage could be expected in the life
of the building.
M Moderately reactive clays that may cause minor 20 to 40mm
movement and damage in the life of the building.
Reasonable care is required in planning the site.
H Highly reactive clays have potential to move more, and H1 40 to 60mm
(H1 & H2) react to variable moisture change conditions. Some minor
damage may occur in the life of the building under normal
H2 60 to 75mm
conditions. More significant damage may occur where site
maintenance conditions are a problem e.g. influence of
trees or leaking underground plumbing or poor drainage.
Particular care is required in planning the site.
E Extremely reactive clays have the potential to react >75mm
significantly to any variable moisture changes in the
foundation clays and require significant attention to
(Note: Movements
detail in planning the site works. Extreme movement and
on E sites have been
damage may occur if the site conditions and foundation
known to move up
maintenance requirements are not observed. Footing
to and in excess
systems and site conditions on “E” sites require very
of 100 to 150mm
detailed specification from an engineer.
in SE Qld)
Page 28
Is it normal to expect cracking
to occur in brickwork, walls
and ceilings?
Yes, damage in varying degrees can
be expected in the life of the building Key points to consider when
depending on the relevant site planning landscaping to avoid
classification. structural damage.
If cracking becomes apparent the site • Plan type and location of
maintenance conditions should be gardens, paths, driveways,
checked as noted under “key points lawns, filling and retaining walls
to consider...” • Take care in selection of trees
Corrective action should be carried out and shrubs. Do not over plant
immediately and may include regrading next to the house
surface drainage, moving gardens and • Keep trees with high water
trees or repairing leaks in water supply, demand well away from
stormwater and/or sewer drainage. buildings in reactive clay areas.
A sound plan for a reactive clay site • Avoid variable conditions
is to provide a consistent moisture around the house and maintain
regime around the building by installing adequate moisture/watering.
paths and patios against the house. Do not over water and avoid
Locate lawns up against paths & patios. the use of unregulated
Garden beds, the most heavily watered sprinkler systems.
parts of a garden, should be kept well
• Locate ponds and water
away from the house.
features away from the house.
If gardens must be placed in close
• Direct surface water away from
proximity to the house, they should be
the house. Do not allow water
sealed with plastic and contain only
to be trapped or pond near
a few small plants. Take care not to
the house.
trap water against the building if using
garden edging. • Repair leaking pipes and taps.
Caution: Care should also be taken if Note: these issues should be
placing filling against the house. Always considered as part of planning
ensure weep holes are not covered and maintaining the home. Aim
and that existing Termite Management to provide a consistent moisture
Systems are not compromised. regime around the house. This will
minimise soil moisture variations
that may cause movement and
result in structural damage.
Page 29
Common sense guidelines for
landscaping and gardens
1. Gardens
Important: It is quite impractical to try If gardens must be placed in close
to prevent gardening activities from proximity to the house, they should be
increasing the moisture content sealed with plastic and contain only
around the foundations of your a few small plants. Take care not to
home. The only practical course is to trap water against the building if using
keep such activities away from the garden edging.
immediate vicinity of the building and Caution: Care should also be taken
so minimise their effects. if placing filling against the house.
A sound plan for a reactive clay site Always ensure weep holes are not
is to provide a consistent moisture covered and that existing Termite
regime around the building by installing Management Systems are not
paths and patios against the house. compromised.
Locate lawns up against paths & patios.
Garden beds, the most heavily watered
parts of a garden, should be kept well
away from the house.
RECOMMENDED LAYOUT FOR GARDENS AND LANDSCAPING
TREES AND
Trees and GARDEN
garden bedsBEDS REQUIRING
requiring HEAVY WATERING
heavy watering SHOULD
should be kept BE KEPT from
well removed WELL REMOVED
the dwelling.
FROM THE DWELLING.
Page 30
2. Paths, patios and driveways
Paths should be laid hard against Concrete pavements should be
brickwork or footings with a fall away constructed in a way that will not
from the house to a stormwater impede surface water flowing away
discharge point. from the building or cause water to
Avoid placing large expanses of pond adjacent to the footings causing
concrete on one side of the house clay foundations to swell.
and heavily watered garden beds On “H” & “E” site classifications,
on the other. particular detail is required to prevent
The water saturated clay in the gardens pavement from moving away from
will expand and swell while the soil the building. Movement in paths could
under the concrete may not move. cause stress on pipes and inspection
Structural damage can result from openings and/or breakages in pipes.
this unco-ordinated movement. Resulting leakages may cause
movement and damage as a result of
clay soils under the house swelling.
RECOMMENDED LANDSCAPING
Page 31
3. Lawns 5. Excessive watering of gardens
If placing lawn areas against the house, and lawns
ensure that filling built up against the
The erection of a building also
wall is graded away and will not allow
indirectly brings with it changes in the
ponding of water to occur. The filling
moisture content to the site. While it
should be impervious clay soil and not
is normal to water gardens and lawns,
sandy loam.
excessive or over watering should be
REMEMBER: Do not cover weep holes. avoided. Consistent and adequate
watering should be observed at all
4. Filling times.
Prior to preparing for gardens, lawns or The location of sprinkler systems next
filling as part of site works, care should to houses should also be avoided on
be taken to ensure the sub-grade or H and E sites.
ground level is graded or sloped away, Sprinkler systems should be as well
especially when filling or top dressing controlled and maintained as practical,
with sandy loam. The sub-grade should and only used in gardens and on lawns
consist of impervious natural site clay. away from the building.
Where elevated floors exist ensure that
the final finished ground level outside
the house is not higher than the sub-
floor area and that water cannot flow
back under the house.
Page 32
6. Site drainage and sloping sites
Design for site conditions, location of
retaining walls, paths, swimming pools,
future structures or proposed extensions
etc. should all be considered when
preparing the site for correct surface
water flow.
If the ground slopes towards the house,
paths with spoon drains should be
provided.
It is also important to place drains uphill
of the footings so as to direct water
around the house and away from the
footings. A stormwater and roof water Seek advice from an engineer
drainage management plan should be
1. To ascertain surface falls which
considered and take into account water
allow for the specific potential
flowing from adjoining properties.
soil movement of the site without
loss of free drainage
2. T
o provide correct mechanical
connection of perimeter paths
of footings
RECOMMENDED DRAINAGE AND
MAINTENANCE ADJACENT TO DWELLING
Page 33
7. Trees and shrubs
The roots of trees and shrubs can Height of Tree(h)
affect footings by removing moisture Distance from house (d)
from clay soils immediately underneath d = 1 h for class H and M sites.
the building causing subsidence as the
d = 1.5 h for class E sites.
clays shrink.
d = 2 h for rows or groups of trees.
In its search for water, a tree root
system can spread a lateral distance 10 to 20 20 to 30 30 to 60
equal to the height of the tree. If in metres metres metres
rows or grouped with other trees the Acacias But-But Blue Gum
roots may spread up to twice the
Ash Cedars Cypress
height of the tree.
Athel Tree English Oak English Elm
Care should be taken when selecting
trees and, as a guide, the trees listed Candlebark Lemon Gum Figs
should not be planted within the Manna Gum Palms Karri
distance of their mature height from Pepper tree Planes Pines
the house depending on the site
Willows Sheoaks Poplars
classification and whether they are to
be planted in a line or in a group. Yate Silky Oak River Gum
Yellow Gum Spotted Sugar
Gum
Casuarina
TREES AND SHRUBS
Page 34
Summary of owner responsibilities for houses under warranty 1. Maintain the site drainage at all times. 5.Do not plant trees within a distance 2.Do not alter the site drainage provided from a building that equates to by the builder. Any changes to the site their mature height. Always plant in drainage should ensure that water will accordance with the requirements for be directed away from the building the relevant site classification. and not pond adjacent to the footing 6.Regularly check and maintain and slab system. Care should also be plumbing, drainage and stormwater taken to avoid directing water flow to systems by immediately carrying adjoining properties. out repairs to leakages or breakages 3.Where possible on reactive clay sites when observed (usually displayed by (Type M,H,E Classifications), avoid seepage and/or greener lawns etc.), placing gardens or installing garden or when minor damage or cracking edging, gravel pavements etc next to exceeding 3-5mm appears in walls the building. This may cause water or ceilings. retention and/or promote a greater By observing these requirements, variation in moisture conditions movement and damage which may be around the building. expected in the life of the building can 4.Installation of sprinkler systems be minimised and maintained within next to dwellings on highly and normal performance requirements. extremely reactive sites (Type H & E Classifications) should be avoided. Adequate and consistent watering only is recommended. Over watering should be avoided. UNSATISFACTORY METHOD FOR CREATING SURFACE FALL AWAY FROM DWELLING
Page 35
Notes: Note: this document has been developed to provide homeowners with general guidance on the maintenace of their homes. It does not purport to address site specific issues. Homeowners should seek professional advice from their builder or engineer when they experience movement in their home or need advice on issues which may affect their home.
Page 36
Need more information?
Visit qbcc.qld.gov.au or call us on 139 333.
QBCC20150210_FCTbrstructuraldamageV3
299 Montague Road,
West End Qld 4101
GPO Box 5099,
Brisbane Qld 4001
T: 139 333
F: 07 3225 2999
W: qbcc.qld.gov.au
Page 37
PRACTICE NOTE GUIDELINES FOR LANDSLIDE RISK MANAGEMENT 2007
APPENDIX C: – QUALITATIVE TERMINOLOGY FOR USE IN ASSESSING RISK TO PROPERTY (CONTINUED)
QUALITATIVE RISK ANALYSIS MATRIX – LEVEL OF RISK TO PROPERTY
LIKELIHOOD CONSEQUENCES TO PROPERTY (With Indicative Approximate Cost of Damage)
Indicative Value of 1: CATASTROPHIC 2: MAJOR 3: MEDIUM 4: MINOR 5:
Approximate Annual 200% 60% 20% 5% INSIGNIFICANT
Probability 0.5%
A – ALMOST CERTAIN 10-1 VH VH VH H M or L (5)
-2
B - LIKELY 10 VH VH H M L
-3
C - POSSIBLE 10 VH H M M VL
D - UNLIKELY 10-4 H M L L VL
-5
E - RARE 10 M L L VL VL
-6
F - BARELY CREDIBLE 10 L VL VL VL VL
Notes: (5) For Cell A5, may be subdivided such that a consequence of less than 0.1% is Low Risk.
(6) When considering a risk assessment it must be clearly stated whether it is for existing conditions or with risk control measures which may not be implemented at the current
time.
RISK LEVEL IMPLICATIONS
Risk Level Example Implications (7)
Unacceptable without treatment. Extensive detailed investigation and research, planning and implementation of treatment
VH VERY HIGH RISK options essential to reduce risk to Low; may be too expensive and not practical. Work likely to cost more than value of the
property.
Unacceptable without treatment. Detailed investigation, planning and implementation of treatment options required to reduce
H HIGH RISK
risk to Low. Work would cost a substantial sum in relation to the value of the property.
May be tolerated in certain circumstances (subject to regulator’s approval) but requires investigation, planning and
M MODERATE RISK implementation of treatment options to reduce the risk to Low. Treatment options to reduce to Low risk should be
implemented as soon as practicable.
Usually acceptable to regulators. Where treatment has been required to reduce the risk to this level, ongoing maintenance is
L LOW RISK
required.
Acceptable. Manage by normal slope maintenance procedures.
VL VERY LOW RISK
Note: (7) The implications for a particular situation are to be determined by all parties to the risk assessment and may depend on the nature of the property at risk; these are only
given as a general guide.
92 Australian Geomechanics Vol 42 No 1 March 2007
Page 38
PRACTICE NOTE GUIDELINES FOR LANDSLIDE RISK MANAGEMENT 2007
APPENDIX C: LANDSLIDE RISK ASSESSMENT
QUALITATIVE TERMINOLOGY FOR USE IN ASSESSING RISK TO PROPERTY
QUALITATIVE MEASURES OF LIKELIHOOD
Approximate Annual Probability
Implied Indicative Landslide
Description Descriptor Level
Indicative Notional Recurrence Interval
Value Boundary
10-1 5x10-2
10 years The event is expected to occur over the design life. ALMOST CERTAIN A
-2
20 years The event will probably occur under adverse conditions over the
10 100 years
design life.
LIKELY B
-3 5x10-3 200 years
10 1000 years The event could occur under adverse conditions over the design life. POSSIBLE C
5x10-4 2000 years
The event might occur under very adverse circumstances over the
10-4 10,000 years UNLIKELY D
design life.
-5 5x10-5 20,000 years
10 The event is conceivable but only under exceptional circumstances
100,000 years RARE E
over the design life.
-6 5x10-6 200,000 years
10 1,000,000 years The event is inconceivable or fanciful over the design life. BARELY CREDIBLE F
Note: (1) The table should be used from left to right; use Approximate Annual Probability or Description to assign Descriptor, not vice versa.
QUALITATIVE MEASURES OF CONSEQUENCES TO PROPERTY
Approximate Cost of Damage
Description Descriptor Level
Indicative Notional
Value Boundary
Structure(s) completely destroyed and/or large scale damage requiring major engineering works for
200% CATASTROPHIC 1
stabilisation. Could cause at least one adjacent property major consequence damage.
100%
Extensive damage to most of structure, and/or extending beyond site boundaries requiring significant
60% MAJOR 2
stabilisation works. Could cause at least one adjacent property medium consequence damage.
40%
Moderate damage to some of structure, and/or significant part of site requiring large stabilisation works.
20% MEDIUM 3
Could cause at least one adjacent property minor consequence damage.
10%
5% 1% Limited damage to part of structure, and/or part of site requiring some reinstatement stabilisation works. MINOR 4
Little damage. (Note for high probability event (Almost Certain), this category may be subdivided at a
0.5% INSIGNIFICANT 5
notional boundary of 0.1%. See Risk Matrix.)
Notes: (2) The Approximate Cost of Damage is expressed as a percentage of market value, being the cost of the improved value of the unaffected property which includes the land plus the
unaffected structures.
(3) The Approximate Cost is to be an estimate of the direct cost of the damage, such as the cost of reinstatement of the damaged portion of the property (land plus structures), stabilisation
works required to render the site to tolerable risk level for the landslide which has occurred and professional design fees, and consequential costs such as legal fees, temporary
accommodation. It does not include additional stabilisation works to address other landslides which may affect the property.
(4) The table should be used from left to right; use Approximate Cost of Damage or Description to assign Descriptor, not vice versa
91 Australian Geomechanics Vol 42 No 1 March 2007
Page 39
PRACTICE NOTE GUIDELINES FOR LANDSLIDE RISK MANAGEMENT 2007
APPENDIX G - SOME GUIDELINES FOR HILLSIDE CONSTRUCTION
GOOD ENGINEERING PRACTICE POOR ENGINEERING PRACTICE
ADVICE
GEOTECHNICAL Obtain advice from a qualified, experienced geotechnical practitioner at early Prepare detailed plan and start site works before
ASSESSMENT stage of planning and before site works. geotechnical advice.
PLANNING
SITE PLANNING Having obtained geotechnical advice, plan the development with the risk Plan development without regard for the Risk.
arising from the identified hazards and consequences in mind.
DESIGN AND CONSTRUCTION
Use flexible structures which incorporate properly designed brickwork, timber Floor plans which require extensive cutting and
or steel frames, timber or panel cladding. filling.
HOUSE DESIGN
Consider use of split levels. Movement intolerant structures.
Use decks for recreational areas where appropriate.
SITE CLEARING Retain natural vegetation wherever practicable. Indiscriminately clear the site.
ACCESS & Satisfy requirements below for cuts, fills, retaining walls and drainage. Excavate and fill for site access before
DRIVEWAYS Council specifications for grades may need to be modified. geotechnical advice.
Driveways and parking areas may need to be fully supported on piers.
EARTHWORKS Retain natural contours wherever possible. Indiscriminatory bulk earthworks.
Minimise depth. Large scale cuts and benching.
CUTS Support with engineered retaining walls or batter to appropriate slope. Unsupported cuts.
Provide drainage measures and erosion control. Ignore drainage requirements
Minimise height. Loose or poorly compacted fill, which if it fails,
Strip vegetation and topsoil and key into natural slopes prior to filling. may flow a considerable distance including
Use clean fill materials and compact to engineering standards. onto property below.
FILLS Batter to appropriate slope or support with engineered retaining wall. Block natural drainage lines.
Provide surface drainage and appropriate subsurface drainage. Fill over existing vegetation and topsoil.
Include stumps, trees, vegetation, topsoil,
boulders, building rubble etc in fill.
ROCK OUTCROPS Remove or stabilise boulders which may have unacceptable risk. Disturb or undercut detached blocks or
& BOULDERS Support rock faces where necessary. boulders.
Engineer design to resist applied soil and water forces. Construct a structurally inadequate wall such as
Found on rock where practicable. sandstone flagging, brick or unreinforced
RETAINING
Provide subsurface drainage within wall backfill and surface drainage on slope blockwork.
WALLS
above. Lack of subsurface drains and weepholes.
Construct wall as soon as possible after cut/fill operation.
Found within rock where practicable. Found on topsoil, loose fill, detached boulders
Use rows of piers or strip footings oriented up and down slope. or undercut cliffs.
FOOTINGS
Design for lateral creep pressures if necessary.
Backfill footing excavations to exclude ingress of surface water.
Engineer designed.
Support on piers to rock where practicable.
SWIMMING POOLS Provide with under-drainage and gravity drain outlet where practicable.
Design for high soil pressures which may develop on uphill side whilst there
may be little or no lateral support on downhill side.
DRAINAGE
Provide at tops of cut and fill slopes. Discharge at top of fills and cuts.
Discharge to street drainage or natural water courses. Allow water to pond on bench areas.
SURFACE Provide general falls to prevent blockage by siltation and incorporate silt traps.
Line to minimise infiltration and make flexible where possible.
Special structures to dissipate energy at changes of slope and/or direction.
Provide filter around subsurface drain. Discharge roof runoff into absorption trenches.
Provide drain behind retaining walls.
SUBSURFACE
Use flexible pipelines with access for maintenance.
Prevent inflow of surface water.
Usually requires pump-out or mains sewer systems; absorption trenches may Discharge sullage directly onto and into slopes.
SEPTIC &
be possible in some areas if risk is acceptable. Use absorption trenches without consideration
SULLAGE
Storage tanks should be water-tight and adequately founded. of landslide risk.
EROSION Control erosion as this may lead to instability. Failure to observe earthworks and drainage
CONTROL & Revegetate cleared area. recommendations when landscaping.
LANDSCAPING
DRAWINGS AND SITE VISITS DURING CONSTRUCTION
DRAWINGS Building Application drawings should be viewed by geotechnical consultant
SITE VISITS Site Visits by consultant may be appropriate during construction/
INSPECTION AND MAINTENANCE BY OWNER
OWNER’S Clean drainage systems; repair broken joints in drains and leaks in supply
RESPONSIBILITY pipes.
Where structural distress is evident see advice.
If seepage observed, determine causes or seek advice on consequences.
Australian Geomechanics Vol 42 No 1 March 2007 113
Page 40
PRACTICE NOTE GUIDELINES FOR LANDSLIDE RISK MANAGEMENT 2007 114 Australian Geomechanics Vol 42 No 1 March 2007
Used in these records
Geotechnical Report_compressed.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.