Geotechnical Report_compressed · MCU22/0052

of 40

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Material Test Report
Report Number:        211008.01-1                                                                                                                    Douglas Partners Pty Ltd
                                                                                                                                                   Sunshine Coast Laboratory
Issue Number:         1
                                                                                                                                   1/28 Kessling Avenue Kunda Park QLD 4556
Date Issued:          17/11/2022
                                                                                                                                                      Phone: (07) 5351 0400
Client:               Quentin Ellis
                                                                                                                                   Email: [email protected]
                           , Noosa Heads QLD 4567
Contact:              Quentin Ellis
Project Number:       211008.01
Project Name:         Proposed Glamping Retreat
Project Location:     332 Eastern Branch Road, Kin Kin QLD
Work Request:         20857                                                                               Accredited for compliance with ISO/IEC 17025 - Testing

Date Sampled:         11/11/2022
Dates Tested:         14/11/2022 - 15/11/2022
Sampling Method:      Sampled by Engineering Department
                                                                                                                        Approved Signatory: Martin Cook
                      The results apply to the sample as received
                                                                                                                         Assistant Laboratory Manager
                                                                                                                     Laboratory Accreditation Number: 828

Shrink Swell Index AS 1289 7.1.1 & 2.1.1
Sample Number                                 SS-20857A                    SS-20857B                    SS-20857C
Date Sampled                                  11/11/2022                   11/11/2022                    11/11/2022
Date Tested                                   15/11/2022                   15/11/2022                    15/11/2022
Material Source                                  Insitu                       Insitu                        Insitu
Sample Location                                  Bore 1                       Bore 3                       Bore 5
                                             (0.6 - 0.75 m)               (0.7 - 0.85 m)                (0.7 - 0.9 m)
Inert Material Estimate (%)                         5                            5                             8
Pocket Penetrometer before (kPa)                  >600                         >600                         >600
Pocket Penetrometer after (kPa)                    450                          480                          350
Shrinkage Moisture Content (%)                    24.8                         18.5                          19.9
Shrinkage (%)                                      2.9                          0.8                           1.5
Swell Moisture Content Before (%)                 28.8                         20.1                          17.9
Swell Moisture Content After (%)                  30.3                         26.9                          26.6
Swell (%)                                          0.2                          0.4                           0.5
Shrink Swell Index Iss (%)                         1.7                          0.6                           1.0
Visual Description                                  **                           **                            **
Cracking                                           SC                           SC                           UC
Crumbling                                           No                           No                           No
Remarks                                             **                           **                            **

Shrink Swell Index (Iss) reported as the percentage vertical strain per pF change in suction.
Cracking Terminology: UC Uncracked, SC Slightly Cracked, MC Moderately Cracked, HC Highly Cracked, FR Fragmented.
NATA Accreditation does not cover the performance of pocket penetrometer readings.




 Report Number: 211008.01-1                   This document shall not be reproduced except in full without approval of the laboratory.                            Page 1 of 1
                                                                Results relate only to the items tested/sampled.

Used in these records

About this file

File size
3.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Geotechnical Report_compressed.pdf · 3.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.