8 Bushfire risk management solutions and recommendations
8.1 Bushfire hazard mitigation recommendations: Considerations
As shown above, the house:
• Is in a Potential Bushfire Impact Buffer area on The Noosa Plan Bushfire Overlay,
• Is in a Potential Bushfire Impact Buffer area on Queensland potential bushfire intensity
mapping,
• Is deemed as being in a Bushfire Prone Area and
• Is assessed as with a construction requirement of BAL 12.5 for all building elevations
Accordingly, this section will recommend bushfire mitigation requirements for the above
assessments with reference to legislative requirements detailed in:
• The Noosa Plan 2020 Bushfire Overlay Code,
• Australian Standard AS 3959 Construction of Buildings in Bushfire Prone Areas and
• State Planning Policy 2017.
8.2 Recommendations for the Noosa Plan 2020 Bushfire Overlay Code
It is recommended that:
• The house is sited in a low hazard area in the lot and achieves a setback of 10 metres from
any retained vegetation and
• There is a reliable reticulated water supply to the lot for fire fighting purposes.
As there is no reticulated water supply to the lot for fire fighting purposes, it is recommended that
• The dwelling to have an on-site water volume of not less than 5,000 litres available for fire
fighting purposes, provided in a separate tank, a reserve section in the bottom part of the
main water supply tank, a swimming pool installed immediately upon construction of the
dwelling or a permanent dam.
8.3 Recommendations for Australian Standard AS3959
Australian Standard AS3959 Construction of buildings in bushfire-prone areas specifies Deemed to
Satisfy bushfire resistant methodologies based on the assessed Bushfire Attack Level.
It is recommended that:
• The building solution for all building elevations to address the Deemed to Satisfy
requirements of Sections 3 and 5 of Australian Standard AS3959-2018 Construction of
buildings in bushfire-prone areas
Bushfire Risk Assessment and Management Plan for a house at 297 Lawnville Rd, Black Mountain December 2020