1 CONCRETE ROOF SEALED WITH WATER PROOF MEMBRANE
2 4 AND LAPS INTO GUTTERS.
3
GUTTERING : COLORBOND ULTRA OR TO MANUFACTURES
.SPECIFICATIONS FOR THIS MARINE ENVIRONMENT.
ROOF GUTTERING TO HAVE AN EFFECTIVE AREA BE 1900sqmm
Elevations GENERAL DOWNPIPE SIZE TO BE 90mm, 100mm & 150mm DIA AS SHOWN
DP (GUTTER TO HAVE OVERFLOW PROVISION
AS PER BCA REQUIREMENTS)
HYDRAULIC ENGINEER TO VERIFY THESE DETAILS PRIOR TO
COMMENCEMENT OF WORK.
NOTE : ALL ROOFING MEMBRANES, GUTTERING, FIXINGS ETC TO BE
SUITABLE FOR THIS MARINE ENVIRONMENT.
REFER TO MANUF. RECOMMENDATIONS FOR PROXIMITY TO LAKE.
ROOF 2 DEGREES
DP
HOLE FOR AIR
CONDITIONING GLASS PYRAMID
SYSTEM 250mm TO APEX
ROOF
ROOF FALL 6mm SOLAR
FALL 6mm
PANELS
ROOF
FALL 6mm ROOF 2 DEGREES
DP
DP