Original source · versioned page text
Response to Information Request - October 2024
“Adamson Town Planning, specialising in providing higher order town planning advice” Response to Information Request: The request for information has been further discussed with the Coordinator, Planning and the applicant (GSLC). It should be noted that the design and location of the maintenance sheds was undertaken in discussion with the adjoining property owners. At the outset, the applicant sought to minimise the impact of the location of the proposed maintenance sheds on the adjoining residential properties. This was achieved by separating Buildings B & C and maximising the amount of landscaping that could be provided, while also having regard to the constrained location (refer Site Plan). The proposed maintenance sheds are the minimum size required to meet the needs of the GSLC in the long term. The maintenance sheds have been separated by 3m to minimise the impact along the length of the built form with dense landscaping to be provided within the 2m building setback and between the sheds. The proposed landscaping will provide a suitable vegetated buffer to the adjoining residential properties, which is a matter that can be conditioned. The building wall length is not excessive (11m for each shed) with the Buildings B & C being separated by 3m. The proposed development meets performance outcome PO19 of the Community Facilities Zone Code. Further, the proposed sheds meet all other acceptable outcomes in terms of building height (AO17.1), site cover, gross floor area and building bulk (AO18.1, AO18.2 and AO18.3 when considering the current Master Plan submitted for the preliminary approval (MCU23/0096)). The height of the sheds near the eastern boundary is 2.7m rising away from the property boundary to about 4m over a length of 6.5m. There are no openings in the walls facing the residential properties with the main access roller doors facing away from these properties. The existing maintenance sheds in this general location face towards the residential properties and the proposed new shed design is considered to be a better planning outcome in terms of maintaining an appropriate level of amenity for the adjoining residential properties. The existing sheds are to be removed. It is noted there is a 2m high fence constructed along the length of the southeastern boundary, which is desirable, given the nature of the use. Consequently, the proposed sheds are 700mm higher than the fence at the closet point and will be mostly screened by landscaping. The location of the maintenance sheds is on a part of the site that is quite constrained given the shape of the allotment and having regard to the existing dam towards the north, with the existing tennis courts also forming a pinch point in this location. Vehicle and machinery access is also required to the maintenance sheds (refer Site Plan). The proposed new maintenance sheds while larger in area will not have a significant impact on the amenity of the adjoining properties. 2|Page 23002 – Good Shepherd Lutheran College – Maintenance and Sports Sheds
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original