Council archive · source document
Planning Assessment Report · MCU19/0008
Attached to the e-mail Detached House in Coastal Protection Area - MCU19/0008.
22 Arakoon Crescent, Sunshine Beach PLANNING ASSESSMENT REPORT Garages, carports and other Class 10a structures O19 S19 Within the Detached Housing, Semi‐Attached Within the Detached Housing, Semi‐Attached The proposal will include a front setback less than six Housing, Attached Housing and Visitor Mixed Use Housing, Attached Housing and Visitor Mixed Use metres, however, this outcome is deemed to be Zones, garages, carports and other Class 10a Zones, garages, and carports and other Class 10a acceptable as it will effectively comply with the structures are designed and sited to visually integrate structures – corresponding specific outcome to provide car with the dwelling unit and avoid dominating the street a) have a front boundary setback of at least 6m; and accommodation which will visually integrate with the by – dwelling unit and not dominate the surrounding b) garage doors that face the street and are visible a) minimising the width of the structure; and streetscape. This compliance is based on the fact that from the road frontage have a maximum width of 6m the proposal will simply replace an existing detached b) minimising projection of the structure forward of within any one plane, with additional garage doors house with a new detached house which will be the main face of dwelling unit. setback an additional 1m from the frontage to break similarly located, designed and constructed. up the width of the garage façade. Water conservation and storage O20 S20 On‐site water storage is provided, designed and If not in a water service area each detached house is The site is located within a reticulated water service operated to support the efficient use of water and is to be serviced with a rainwater tank of the following area. adequate for occupant’s everyday use. minimum storage capacity – a) for detached houses with no more than 3 bedrooms – 45,000 litres; or b) for detached houses of more than 3 bedrooms or where including a 2nd dwelling unit on the same premises – 60,000 litres. O21 S21 Detached houses and ancillary dwelling units within If not in a reticulated water service area – there is, on The site is located within a reticulated water service bushfire hazard areas have sufficient water supply for the lot, a dam, swimming pool or water tank area. firefighting purposes. accessible for use by the fire brigade that contains at least 5,000 litres of water. Editor’s note: The 5,000 litres required in S20.1 can be included within the water required in S21.1 providing it is accessible for the purpose of firefighting at all times and not used for other domestic purposes. TP19/5080 © Bartley Burns Certifiers & Planners P a g e | 26
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Planning Assessment Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.3 MB (small file)
- File type
No other editions are linked here.