NOOSA COUNCIL IDAS Development Application Decision Notice 5 of 13
24. The applicant shall provide a 2m by 2m truncation on each corner of Lot 4 adjacent to Lot 1 on RP802360
on either side of Council’s pathway to assist service vehicle access. An underground electricity service
shall be provided to service all parts of Lot 4 if not already provided. In this regard, an approved
ENERGEX Electrical Design Consultant shall work in conjunction with Council’s Manager - Works Support
to prepare detailed designs of the electrical proposal. The detailed deigns shall then be submitted to
ENERGEX for approval and a copy of their approval submitted to Council in conjunction with a “Certificate
of Electricity Supply for Proposed Subdivisions” (prepared by an approved ENERGEX Electrical Design
Consultant) prior to Council endorsing the Plan of Survey. Any agreement with ENERGEX or an
approved ENERGEX Electrical Design Consultant shall be wholly at the applicant’s expense and shall not
entail a financial encumbrance on future purchasers of the proposed lots.
25. All parts of lot 4 shall be serviced by water supply appropriate for necessary requirements, such as fire
fighting prior to endorsement of the plan of survey.
Vehicle Access
26. The eastern site access intersection shall be modified to increase the length of the parallel right turn
storage lane to at least 20 metres.
27. The existing primary vehicular access driveway off Goodchap Street (eastern access) shall be modified by
the construction of a splitter island at the entrance should be extended to preclude right turns in or out of
the car parking aisle along the front of the eastern building.
28. All driveways shall be designed and constructed to Council’s design standards and to grades that prevent
vehicles from scraping and/or bottoming whilst also allowing pedestrians movements along the footpath
without any step or level difference. Should any driveways be constructed to grades that do not comply
with AS2890.1-2004, Council will require that the driveway be removed and reconstructed to levels that do
comply.
29. To ensure pedestrian safety between vehicles exiting the site and pedestrians/cyclists on the footpath, the
driveway and any associated fencing or vegetation near the driveway shall comply with the minimum sight
line requirements as defined in AS2890.1, section 3.2.4. The applicant shall demonstrate compliance by
illustrating these sight lines on the plans submitted for both Operational Works approval and Building
Works approval.
30. Condition 9 shall also apply to the crossing of the existing pathway between the two parts of Lot 4.
Buildings shall be modified as necessary to achieve these sight distances and this compliance
demonstrated in the plans submitted as part of the operational works approval. The crossing shall also be
a raised type, be appropriately lit and give priority to pedestrians and cyclists.
31. The access to and from Traders Lane will only be permitted for use by service and emergency vehicles. A
sign indicating this shall be installed at the exit.
32. In any operational works application, the developer shall demonstrate by the way of a turning template,
that service and emergency vehicles can access the site via Traders Lane. If this cannot be achieved the
building shall be set back or modified to allow entry of these vehicles.
33. All vehicles shall enter and leave the site in a forward direction.
Loading Areas
34. Two combined loading zone/carpark spaces shall be included on site and operate as a Loading Zone
between the hours of 8 am to 11 am weekdays and shall be sign posted to indicate this.
35. The combined loading zone / carpark space shall be sized to accommodate a small rigid vehicle in
accordance with AS 2890.2 - 1989. These spaces will be indicated on the operational works application
for car parking.
Car Parking
Off Street
36. A minimum of 290 carpark spaces shall be provided on site, including six clearly defined disabled carpark
spaces.
37. All public parking spaces should be a minimum of 5.4m by 2.6m with 6.2m wide aisles, although staff
parking spaces may be reduced to 5.4m by 2.4m with 6.2m aisles. In all other respects, the designs
should comply with AS2890.1 - 2004.
MSOffice c:\docume~1\shesse\locals~1\temp\bcl technologies\easypdf 5\@bcl@b00795bc\@[email protected]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED Decision Notice - 010.2007.00000012.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 61 KB (small file)
- File type
No other editions are linked here.