39 Lorilet 06 Landslide Hazard Overlay Code
Performance outcomes Acceptable outcomes
structure:-
1. has a maximum undercroft height at
the perimeter of the building of 3
metres above ground level; or
2. incorporates landscape screening for
the full height of any undercroft higher
than 3 metres above ground level at the
perimeter of the building.
Editor's note- Vertical battens are also useful to
enclose the undercroft area.
AO3.7
On sloping sites roof lines are generally parallel with Existing buildings comply.
contours of the land and roof pitch does not exceed
15 degrees.
PO4 AO4.1 Existing site development complies.
Development on sloping sites provides safe and Driveways are not steeper than 20% for more than
efficient access for vehicles and pedestrians 20 metres or one quarter of their length, whichever
is the lesser, and not steeper than 25% in any
location.
AO4.2
Vehicle turning areas are provided at the end of Existing site development complies
driveways so that it is not necessary to reverse up or
down driveways.
AO4.3
Existing site development complies.