20180192 - Change Application Package · 51901.4379.01
Attached to the e-mail Change to Development Approval - 51901.4379.01.
GENERAL NOTES
DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY. IF IN DOUBT, ASK.
THE OWNER/BUILDER SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS,
SETBACKS AND SPECIFICATIONS PRIOR RO COMMENCING WORKS OR ORDERING
MATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKS
CONFORM TO THE NATIONAL CONSTRUCTION CODE OF AUSTRALIA, CURRENT
AUSTRALIAN STANDARDS, BUILDING REGULATIONS AND TOWN PLANNING
REQUIREMENTS, REPORT ANY DISCREPANCIES TO THIS OFFICE.
ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE BUILDING CODE OF
AUSTRALIAN AND THE AUSTRALIAN STANDARDS LISTED IN NOTE 4.
EXISTING
AS 1288 - 2006 GLASS IN BUILDINGS - SELECTION AND INSTALLATION POOL
AS 1562 - 2006 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDING
AS 1684 - 2010 NATIONAL TIMBER FRAMING CODE
AS 2049 - 2002 ROOF TILES
AS 2050 - 2002 INSTALLATION OF ROOF TILES
AS 2870 - 2011 RESIDENTIAL SLAB AND FOOTINGS - CONSTRUCTION
AS/NZS 2904 - 1998 DAMP-PROOF COURSES AND FLASHINGS
AS 3600 - 2010 CONCRETE STRUCTURES
AS 3660 - 2004 BARRIERS FOR SUBTERRANEAN TERMITES
AS 3700 - 2011 MASONRY IN BUILDINGS
AS 3740 - 2010 WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGS
AS 3786 - 2004 SMOKE ALARMS
AS 4055 - 2012 WIND LOADINGS FOR HOUSING
AS 4100 - 2012 STEEL STRUCTURES
THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY SOIL, STRUCTURAL AND
EXISTING
CIVIL ENGINEERING COMPUTIONS AND DRAWINGS. UNIT 4
ALL BUILDINGS SHALL BE PROTECTED AGAINST TERMITE ATTACK IN ACCORDANCE
WITH AS 3660.1 AND A DURABLE NOTICE SHALL BE PLACED IN THE METER BOX
INDICATING TYPE OF BARRIER AND REQUIRED PERIODICAL INSPECTIONS. UNIT 3
SAFETY GLAZING TO BE USED IN THE FOLLOWINGS CASES -
i) ALL ROOMS - WITHIN 500mm VERTICAL OF THE FLOOR
ii) BATHROOMS - WITHIN 1500mm VERTICAL OF THE BATH BASE UNIT 2
iii) FULLY GLAZED DOORS
iv) SHOWER SCREENS
v) WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR LEVEL
vi) WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZES WILL VARY
UNIT 1
WITH MANUFACTURER, AND ARE TO BE VERIFIED WITH SAME. FLASHING ALL ROUND.
STORMWATER TO BE TAKEN TO ON SITE STORAGE OF PROVIDED, THEN THE LEGAL
POINT OF DISCHARGE AS DETERMINED BY THE RELEVANT AUTHORITY.
TILED DECKS OVER LIVABLE AREAS ARE TO BE, IN THE FOLLOWING ORDER OVER THE
FLOOR JOISTS : 19mm COMPRESSED FIBRE CEMENT SHEET, WITH ONE LAYER OF
PARCHEM EMERPROOF 750 WITH A SECOND LAYER OF SAND SEED WITH A DFT OF
1300 MICRON, INSTALLED TO MANUF. SPECIFICATIONS, AND FLOOR TILES OVER, ALL
CORNERS TO HAVE 20mm MASTIC SEALANT UNDER THE PARCHEM EMERPROOF 750.
FOOTINGS ARE TO BE WHOLLY WITHIN TITLE BOUNDARIES AND ARE NOT TO ENCROACH
EASEMENTS. IT IS RECOMMENDED THAT WHERE BUILDINGS ARE TO BE LOCATED IN
CLOSE PROXIMITY OF BOUNDARIES, A CHECK SURVEY BE CONDUCTED BY A LICENSED
SURVEYOR. EXISTING
ALL STEELWORK IN MASONRY TO BE HOT DIP GALVANISED. UNIT 4
ALL WET AREAS TO COMPLY WITH BCA 3.8.1.2 AND AS 3740. SPLASH BACKS SHALL
BE IMPERVIOUS FOR 150mm ABOVE SINKS, TROUGHS AND HAND BASINS WITHIN CARPORT
75mm OF THE WALL.
PROVIDE WALL TIES AT 600mm SPACINGS BOTH VERTICAL AND HORIZONTAL AND
WITHIN 300mm OF ARTICULATION JOINTS. BRICK TIES TO BE STAINLESS STEEL.
SUB-FLOOR VENTILATION MINIMUM 7500mm/sq FOR EXTERNAL WALLS AND
1500mm/sq FOR INTERNAL WALLS BELOW BEARER.
THERMAL INSULATION TO BE PROVIDED TO ACHIEVE MINIMUM REQUIREMENTS AS
SPECIFIED BY LICENSED ASSESSOR.
STAIR REQUIREMENTS : MIN. TREAD 240mm, MIN. RISER 115mm, MAX. RISER 190mm,
SPACE BETWEEN OPEN TREADS MAX. 125mm. TREADS TO BE NON SLIP SURFACE.
BALUSTRADES : MIN. 1000mm ABOVE LANDINGS WITH MAX. OPENING OF 125mm AND
IN ACCORDANCE WITH BCA 3.9.2
FOR STAINLESS STEEL BALUSTRADE, REFER TO Table 3.9.2.1 (WIRE BALUSTRADE SITE PLAN
CONSTRUCTION - REQUIRED WIRE TENSION AMD MAXIMUM PERMISSIBLE
DEFLECTION) OF THE BCA. SCALE : 1 : 200 4/5 MITTI ST, NAOUSA, N
THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE STABILITY OF
EXISTING AND NEW STRUCTURES THROUGH-OUT CONSTRUCTION.
NOOSA HEADS
DENOTES LOCATION OF SMOKE DETECTORS (refer electrical layout plans),
TO BE HARD WIRED WITH EMERGENCY BACK-UP AND COMPLY WITH AS 3786. Lot 4 GTP779
PROVIDE LIFT OFF HINGES, OPEN OUT DOOR OR MIN 1200mm CLEARANCE FROM DOOR
TO PAN IN WATER CLOSETS. AREA: 15.1 m²
EXHAUST FANS FROM SANITARY COMPARTMENTS ARE TO BE DUCTED EXTERNALLY
OR TO A VENTED ROOF SPACE IN COMPLIANCE WITH AS 1668.2 PROPERTY iD: 130552
THESE NOTES ARE NEITHER EXHAUSTIVE NOR A SUBSTITUTE FOR REGULATIONS,
STATUTORY REQUIREMENTS, BUILDING PRACTICE OR CONTRACTUAL OBLIGATIONS.
THESE PLANS ARE PROTECTED BY COPY RIGHT AND ARE THE PROPERTY OF THE
AUTHOR.
DRAWING TITLE:
GENERAL NOTES: CLIENT NAME: Peter Gray
Use written dimensions only. DO NOT scale drawings. Contractors to verify all Site Plan SITE ADDRESS: Unit 4 / 5 Mitti Street, Noosa Heads
dimensions and levels on site prior to commencing works and shop drawings.
Site location is Category N3 or to engineer's requirements.
These drawings are to be read in conjunction with engineer's design and Mar 2017 DRAWING No:
A001
ISSUE: E DATE: 27/06/2018 DATE:
details, the accompanying building specification and schedule of finishes.
Ph 0403 191 223 www.natanidesign.com qbcc 1243419 SCALE: 1 : 200 SHEET SIZE: A3
If in doubt, please request clarification. DO NOT ASSUME.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
20180192 - Change Application Package.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.4 MB (small file)
- File type
No other editions are linked here.