6.0 Planning Report

of 29

Page text shows just the words. Original shows the document exactly as it was published.

                                                                                                                        Building Suncoast Green
                                                                                                    P: 07 5448 8500 E: [email protected]
                                                                                    Town Planning – Building Design – Development Management
 Effluent Disposal                                      No solution provided (no requirement for accepted
 O22 Effluent disposal does not have a significant      development development)                                Complies – The proposed Ancillary Dwelling Unit is
 adverse effect on biodiversity, natural vegetation                                                             within an existing building with working effluent
 or water quality22.                                    Editor’s note:                                          disposal systems.
                                                        PSP24 – Effluent Disposal details requirements for
 O23 Treatment and disposal of wastewater does          the design and siting of effluent disposal systems
 not have any detrimental impact on Noosa’s major       where located outside a sewerage service area.
 water storage and supply - Lake Macdonald.             Compliance with PSP24 will be considered as part of
                                                        Council’s assessment of the plumbing and drainage
                                                        application.
 Environmental Protection                               S24.1 Where there is an existing building envelope
 O24 The design, siting and construction of buildings   on the lot that contains vegetation protection          Complies – The proposed Ancillary Dwelling Unit is
 and structures minimise the clearing of vegetation     measures, clearing of native vegetation and             within an existing building and does not require
 and where there is an existing preliminary approval    building works do not extend beyond the building        external development.
 that includes vegetation protection measures for       envelope, except for the purposes of a driveway
 the property, the proposal is consistent with those    access;
 measures                                               AND
                                                        S24.2 Where there is no building envelope existing
                                                        on the lot, clearing of native vegetation, other than
                                                        for a driveway access does not extend beyond—
                                                        a) 30m of a building or 10m of a structure on lots
                                                            greater than 10ha; or
                                                        b) 10m of a building or structure on lots 10ha or
                                                            less but more than 0.3ha in area; or
                                                        c) 3m of a building or structure on lots 0.3ha or
                                                            less.




Building Suncoast Green                                                   (07) 5448 8500                                               [email protected]
Log in to download the original file

6.0 Planning Report.pdf · 1.9 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.