Site Calculations

site area 607.02m2
site cover 242.88m2 (40%)
g-f.a. 273.00m2 (45%) |273m2 (45m2) allowed

 

 

no. people 6.6
landscape area 335m2 (32%)

Real Property Description

Lots 106 & 107
Reg. Plan No. 94566
Parish of Weyba

Drawing Legend

Sheet No. Drawing Title

Site Plan

Floor Plan - Level 1
Floor Plan - Level 2
Floor Pian - Level 3
Dimension Plan - Level 1
Dimension Plan- Level 2
Dimenston Plan - Level 3
Elevations

Elevations

 

 

 

 

 

 

 

(OO Nigiag a win] =»

 

 

 

a cians hel crewings shown PROPOSED 2x3 BEDROOM UNITS Drawing No. Drawing Title

end remola the property of FOR STEVE & DIANNE SELBY

PResidenthel Design Studia”

 

 

inode aar-|—AT-LOT_219,CORSAIR-CRESENT—SUNRISE-GEACH| Date “Site Pian

plans is prohibited.

 

|
|

Eu

j
|

Clients Signature
of these plons)

Do not scale plans, use written dimensions only. If any
discrepancies are found, the following must be notified
RESIDENTIAL DESIGN STUDIO-PHONE 5448 9000

Cut/fill indicated on plans may vary at construction

stage, & builder to adjust as required .
Any variation at construction stage is to comply with
local building authority on earthworks/drainage

All cut & fill embankments up to 1 m in height

are to be no greater than 1 in 4

Retaining Walls

All retaining walls and embankments are to comply
with local building authority requirements

Any retaining wall over 1 m in height must be
engineer designed.

Position of retaining walls & embankments may
vary to suit site works.

Contours & Levels

Floor slabs to finish a minimum of 300mm above
prepared platform level, 225mm above finished
ground level.

Timber floor framing to finish to heights above

aS shown on drawings.

All surfaces adjacent to buildings for a minimum
width of 1m ,to be graded away from buildings
to a minimum slope of 1 in 20

Level at alignments to be in accordance with local
building authority requirements.

Owner /builder is responsible for accuracy of cut/fill
levels.

ie

Drainage

All sewage & wastewater to be discharged to local
building authority requirements.

Licensed plumber & drainer or local building
authority to prepare drainage plans.

All‘ rainwater from roof discharge to be drained to
street channel or as directed by local building
authority.

All boundary clearances shown are to verified by
builder prior to set out & commencement of ony
construction.

It is recommended that a licensed surveyor be
engaged to ensure minimum setbacks are not
encroached on.

Owner/Builder to confirm correct building allotment.
Builder to confirm position of all services prior to
commencement of construction.

Phone 0408 718 069

Noosaville QUD 4566

 

Used in these records

About this file

File size
2.1 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_2062 - MCU - Multiple Housing Type 2 - Duplex [As Published].pdf · 2.1 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.