UNIT 2 - GROUND FLOOR ELECTRICAL LEGEND - INTERNAL
AP - APPLIANCE CUPBOARD
DESCRIPTION No. BC - BROOM CUPBOARD
C'BD - CUPBOARD
FAN - CEILING FAN ONLY 2 DP - DOWNPIPE
DW - DISHWASHER PROV.
LIGHT FITTING - RECESSED COMPACT FLURO 1 FW - FLOOR WASTE
LIGHT FITTING - RECESSED LED 8 GAS - GAS CONNECTION
HP - HOT PLATE
LIGHT FITTING - WALL MOUNT UP/DOWN 1 HWS - HOT WATER SYSTEM
POINT - DOUBLE GPO 8 L - LINEN
MH - MANHOLE
POINT - SINGLE GPO 1 MW - MICROWAVE PROV.
OHC - OVERHEAD CUPBOARD
POINT - SINGLE WATERPROOF GPO 2 PTY - PANTRY
R - ROBE
REF - REFRIDGERATOR SPACE
RH - RANGEHOOD
SH - SHELF
TR - TOWEL RAIL
TRH - TOILET ROLL HOLDER
UBO - UNDER-BENCH OVEN
WO - WALL OVEN
LEGEND - EXTERNAL
BV - BRICK VENEER
CJ - CONTROL JOINT
FC - FIBRE CEMENT SHEETING
RH - RENDERED HEBEL PANELS
RBB - RENDERED BLUEBOARD
RB - RENDERED BRICKWORK
RBL - RENDERED BLOCKWORK
SA - SCYON AXON
SL - SCYON LINEA
SM - SCYON MATRIX PANELING
SS - SCYON STRIA CLADDING
ELECTRICAL LEGEND WB - HARDIES NEWPORT
CEILING FAN
A/C UNIT
CEILING FAN / LIGHT COMBINATION POOL PUMP
DN
GHWU
ISSUE
EXHAUST FAN
# DATE DETAILS BY
- 21-09-19 INCOMPLETE DC
HEAT FAN & LIGHT
UP - 26-09-18 PRELIM ISSUE DC
- 23-10-18 WD ISSUE DC
LIGHT POINT - RECESSED CFL LED
1000 E 18-06-19 SITE REV DC
F 09-06-21 PRE-CONTRACT
LIGHT POINT - RECESSED LED 1000
LED
WM - - - -
UP/DOWN WALL MOUNT LED
1000 - - - -
EXTERNAL FLOOD LIGHT
LED - - - -
EXTERNAL WALL LIGHT
SINGLE FLURO
LED
GPO - DOUBLE po box 6384 p (07) 5442 6413
LED maroochydore f (07) 5450 6437
qld 4558 QBCC 1083000
GPO - SINGLE AC
This plan remains copyright to
Ausmar Group and may not be
GPO - DOUBLE WEATHERPROOF used in part or in whole without
the written consent of the author.
LED
GPO - SINGLE WEATHERPROOF © 2017 Ausmar Group
LED WRITTEN DIMENSIONS TO
TELEPHONE POINT TAKE PRECEDENCE OVER SCALE
DATA POINT AC
U2 - GROUND
TELEVISION POINT ONLY FLOOR
HDMI POINT ELECTRICAL
PROJECT DESCRIPTION:
Proposed Duplex For:
SMOKE ALARM
CLIENT:
METER BOX MR K ANSCHAU
HWS HOT WATER SYSTEM
ghwu
GAS HOT WATER UNIT UNIT 2 - GROUND ELECTRICAL SITE ADDRESS:
LOT 1 WERIN ST
WP WATER PUMP 1 : 100
SINGLE LIGHT SWITCH TEWANTIN
DESIGNED BY REDDOOR
DOUBLE LIGHT SWITCH
CUSTOM
DRAWN BY D CARTER
3 GANG LIGHT SWITCH SCALE JOB CODE
1 : 100
NOTE: ALL LIGHT SWITCHES LOCATED @ 1000mm ABOVE FL.
DATE
09-06-21
D-KA
UNLESS OTHERWISE NOTED,
ALL POWER OUTLETS LOCATED 300mm ABOVE FL. UNLESS
OTHERWISE NOTED & WITH BCA REQUIREMENTS. SHEET 29 OF 33