2.2.1.2 Defined Flood Levels and Flood Immunity
An assessment was completed to identify if the proposed buildings associated with the development will achieve the required 0.5m
freeboard. Table 2.5 provides a summary of the floor levels along with associated defined flood level, freeboard provided and if it achieves
the minimum 0.5m freeboard (SC6.7.5 Specific Design and Construction Requirements – Clause (2) (m) (iv)). When reviewing the results,
each building achieves the minimum freeboard required. It is noted that FFL2 achieves its freeboard through the inclusion of a wall (approx.
1m high) to contain flows within the flow path. Figure 2.5 provides an overview of finished floor levels, top of wall levels and defined flood
height (i.e. 1% (2100) AEP).

TABLE 2.5: SUMMARY OF FINISHED FLOOR LEVELS AND FLOOD IMMUNITY.

 Section             Finished Floor Level      Top of Wall (m AHD)         DFL (m AHD)    Freeboard Achieved     Min 0.5m Freeboard
                           (m AHD)                                                               (m)                  Achieved

 FFL1                        18.60                        -                   18.05               0.55                     ✓

 FFL2                        17.75                     18.75*                 17.80               0.95                     ✓

 FFL3                        18.25                        -                   17.55               0.70                     ✓

 FFL4                         18.0                        -                   17.49               0.51                     ✓

 FFL5                         18.0                        -                   17.22               0.78                     ✓

 FFL6                         19.0                        -                   17.01               1.99                     ✓

 Foot Bridge                 18.90                        -                   16.92               1.98                     ✓

* The flood immunity to this building is provided by an impervious wall.




NOOSA CALILE I BBNE01676-0001-REP-001-0                                                                                                    11
Log in to download the original file

BBNE01676-0001-REP-001-0-Noosa Calile Overland Flow_Optimized.pdf · 14.3 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.