Original source · versioned page text
BBNE01676-0001-REP-001-0-Noosa Calile Overland Flow_Optimized
Very large file (14.3 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 6, section 1. The text section number identifies this passage in the reader.
1.4 Performance Criteria
The adopted for the development with respect to the management of overland flow:
• Overland Flow:
– Development site and buildings to achieve appropriate freeboard above the 1% (2100) AEP flood level.
– No external impacts to adjoining properties.
– Footpath at end of Serenity Close achieves a depth x velocity project less than 0.4m2/s and depth less than 0.25m in 1% (2100) AEP.
– Assessment of severe storm (i.e. 1% (2100) AEP event with 100% blocked pipes).
NOOSA CALILE I BBNE01676-0001-REP-001-0 3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.