APPROVED PLAN CODE DESCRIPTION FINISH FT3 2m Powdercoated Aluminium Screen XXXX
MCU23/0094.02, OPW23/0113.02 & RAL23/0014.02
7 JULY 2025 AWN1 Awning Hood Powder Coated Aluminium Surfmist PV1 Feature Driveway Entry Beauford Crazy Pave
AWN2 Awning Hood Powder Coated Aluminium Surfmist RN1 Render Resene Black White
BAL3 Aluminium and Clear glass balustrade Powder Coated Aluminium Surfmist RN2 Render with Sawcuts Concrete Look
BAL4 Solid Balustrade Birch RN3 Render with Sawcuts To Match Surfmist
BAL5 Aluminium and Clear glass balustrade Powder Coated Aluminium Surfmist RN4 Render over cladding Resene Black White
BAL6 Aluminium and Translucent glass balustrade Powder Coated Aluminium Surfmist RN5 Render with Sawcuts over cladding Concrete Look
CLD1 Hardies Oblique Resene Black White RS1 LYSAGHT Colorbond roof sheet Colorbond Surfmist
CLD2 Hardies Axon Limed SCN1 Aluminium Batten Screen - angled Powder Coated Aluminium Surfmist
DP PVC Downpipe Wall colour SF1 Soffit lining Resene Black White
EA CONC Driveway; Exposed Aggregate Concrete Silver Frost SF2 Soffit lining Pre-finished
EG1 Eaves Gutter Stramit 175 Quad Colorbond Surfmist SF3 Soffit lining - Territory Panel Limed
FF1 External Tile Paradise Stone Ivory
FT1 2m High Perimeter Fencing Timber Pailing Resene Black White
FT2 1.4m Screen above Rendered Blockwork XXXX
FT3 2m Powdercoated Aluminium Screen XXXX
TRUSS ROOF FRAMING TO
1.6 2.6 STRUCTURAL ENGINEERS &
3.6 4.6
MANUFACTURERS DETAILS
UNIT 601 & 603
8M HEIGHT LIMIT
RL+19.300
RC RC
EG1 RS1 RS1
EG1 EG1
2400 WINDOW &
CLD2
DOOR HEAD HEIGHT
2,700
KITCHEN DINING LIVING TERRACE
PLANTER DP
ENTRY
UPPER LEVEL
D.11 Bal3
FFL+15.330 AD.17 FFL+15.330
EG1 D.11
2400 WINDOW &
CARPORT DOOR HEAD HEIGHT
KITCHEN DINING LIVING TERRACE
2,700
RN1 ENTRY
RN2 DP
FT6 GROUND LEVEL
FFL+12.250 FFL+12.250
D.11
FINISHED DRIVEWAY
NATURAL GROUND
FINISHED GROUND
SLAB & FOOTINGS TO STRUCTURAL
ENGINEERS DETAILS
A BUILDING 6 SECTION
- Scale 1:100
TRUSS ROOF FRAMING TO
A.6 B.6 STRUCTURAL ENGINEERS & C.6
MANUFACTURERS DETAILS
UNIT 601 & 603 UNIT 602 & 604
8M HEIGHT LIMIT
RL+19.300
EG1 EG1
2400 WINDOW &
W.02 W.02
DOOR HEAD HEIGHT
2,700
2,700
AWN2 AWN2
KITCHEN
ENSUITE
DP FFL+15.330 FFL+15.330 FFL+15.330
DP
AWN2
2400 WINDOW &
W.02
DOOR HEAD HEIGHT
2,700
2,700
AWN2
2,400
2,400
BATH KITCHEN KITCHEN
ENSUITE
BREAK TANK
FFL+12.250 FFL+12.250
NATURAL GROUND FINISHED DRIVEWAY
FINISHED GROUND SLAB & FOOTINGS TO STRUCTURAL
ENGINEERS DETAILS
B BUILDING 6 SECTION
- Scale 1:100
Notes:
B L A C K Project: Drawing Title: Project No. Drawn By Drawing No.
Rev Date Description Use figured dimensions in preference to scale. Contact information:
1 28/11/2024 BUILDING APPROVAL ISSUE All dimensions to be varified and checked on
2 13/12/2024 BUILDING APPROVAL RFI ISSUE site. These designs, drawings, specifications
PO Box 781 Tewantin Q 4565 79 - 83 Eumundi Noosa Road B6 - SECTIONS 202327 PT WD.6.07
Architect Registration # 5386 QLD
and the copyright thereof are the property of For CAPITAL PRUDENTIAL
4
5
28/02/2025
10/03/2025
CONSTRUCTION ISSUE
Concil AMdendment Issue
Blackwood and must not be used, retained or W O O D Ph: 0416 037 424
[email protected] 79 - 83 EUMUNDI NOOSA ROAD & 26 Scale Date Project Stage Revision
copied without the written authority of
6 25/03/2025 Pools & Landscape Calculation Revised Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au HEADLAND DRIVE, NOOSAVILLE QLD 4566 1:100, 1:1 @ A1 25/03/2025 Building Approval 6
Document Set ID: 23656562
Version: 1, Version Date: 26/03/2025
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewLog in to download the original (Attachment 2 - Existing Approval.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.