Original source · versioned page text
MCU18.0166 - Response to Information Request (amended)
Radio Systems at the Site
This base station currently has equipment for transmitting the following services:
Carrier Radio Systems
Vodafone GSM900, WCDMA2100, WCDMA900, LTE850
Telstra LTE700, WCDMA850, LTE1800
It is proposed that this base station will have equipment for transmitting the following services:
Carrier Radio Systems
Vodafone GSM900, WCDMA2100, WCDMA900, LTE850
Telstra LTE700, WCDMA850, LTE1800
NBN Co LTE2300 (proposed)
Calculated EME Levels
This table provides calculations of RF EME at different distances from the base station for emissions from existing equipment
alone and for emissions from existing equipment and proposed equipment combined.
Maximum Cumulative EME Level – All carriers at this site
Distance from the antennas
at Cooran 265 Tablelands Existing Equipment Existing and Proposed Equipment
Road
Electric Field Power Density % ARPANSA Electric Field Power Density % ARPANSA
in 360 circular bands V/m mW/m² exposure limits V/m mW/m² exposure limits
0m to 50m 3.63 34.88 0.65% 3.72 36.65 0.67%
50m to 100m 7.067 132.46 2.32% 7.092 133.4 2.33%
100m to 200m 7.011 130.39 2.28% 7.034 131.26 2.29%
200m to 300m 5.15 70.27 1.14% 5.45 78.75 1.23%
300m to 400m 3.49 32.35 0.52% 4.039 43.28 0.63%
400m to 500m 2.63 18.34 0.3% 3.075 25.086 0.36%
7.067 132.46 2.32 7.092 133.4 2.33
Maximum EME level 97.6 m from the antennas at Cooran 265 97.6 m from the antennas at Cooran 265
Tablelands Road Tablelands Road
Calculated EME levels at other areas of interest
This table contains calculations of the maximum EME levels at selected areas of interest that have been identified through the
consultation requirements of the Communications Alliance Ltd Deployment Code C564:2011 or via any other means. The
calculations are performed over the indicated height range and include all existing and any proposed radio systems for this site.
Maximum Cumulative EME Level
Height / Scan All Carriers at this site
Additional Locations relative to location Existing and Proposed Equipment
ground level
Electric Field Power Density % of ARPANSA
V/m mW/m² exposure limits
POI 1 Residence 1 Tablelands Road,Co... 0m to 3m 2.62 18.17 0.19%
POI 2 Residence 2 Tablelands Road, C... 0m to 3m 3.42 31.026 0.54%
POI 3 Residence 3 Akuna Lane Cooran 0m to 3m 1.33 4.71 0.061%
POI 4 Residence 4 Brewers Road, Coo... 0m to 3m 1.54 6.32 0.098%
Environmental EME report (v11.3, Feb 2014) Produced with RF-Map 2.0 (Build 1.18) NAD (v1.0.68342.26750)