Facsimile Transmission
File No: 2008/1056
Date: 11 July 2008
Fax No: 07 5443 5642
To: Cardno (Qld) Pty Ltd
Attention: Mike Laverty – Your Ref: 2384-01
From Kevin Slender, Technical Assessment Officer
Phone No: 07 5449 5216 Fax No: 07 54471062
Re: Operational Works Application: Roadworks, Stormwater &
Earthworks
At: 71 Pacific Ave Sunshine Beach, being Lot 31 RP149005
Proposed Childcare Centre for the Comiskey Group
Information Request
The following items require attention in order to progress the assessment
of this application:
1. Please note that a copy of the Portable Long Service Leave payment receipt will need
to be forwarded to Council prior to the issue of an Operational Works Permit.
2. The Security amount referred to in Condition 15 of the Court Order dated 5 March
2008 will need to be paid prior to the issuance of a Development Permit for
Operational Works.
3. Please note that the Contributions referred to in Condition 52 of the Court Order dated
5 March 2008 will need to be paid prior to the issuance of a Development Permit for
Operational Works.
4. Please provide a plan illustrating the sight line requirements for vehicles exiting the
site, in accordance with Condition 22 of the Court Order dated 5 March 2008.
5. Please advise whether minimum Safe Intersection Sight Distance (SISD), as required
by AUSTROADS Part 5, Table 5.3, has been achieved at the proposed driveway, with
regards to vehicles approaching from the east.
6. To encourage pedestrians to use the existing Refuge Island when crossing Pacific
Avenue, please extend the proposed 2.0m wide concrete footpath easterly passed the
development’s frontage to join the existing footpath on the eastern side of Weyba
Street. This will require the construction of “Pram Ramps” within the kerbs of Weyba
Street.
7. Please provide more detail/information about the 4 x 100 dia holes cored through the
western block wall. Please note that it is not permitted to discharge stormwater over
the verge in David Low Way.
IMPORTANT AND LEGAL PRIVILEGE NOTICE:
The information contained in this facsimile message is CONFIDENTAL and may be subject to legal privilege. If you are not
the intended recipient, you are notified that any use of this message is prohibited. If you received this message in error,
please notify us immediately by telephoning 07 54495200 and destroy the original.
Page: 1 of 2
Original to follow: No
Sunshine Coast Regional Council Tewantin Office 9 Pelican Street TEWANTIN (PO Box 141 TEWANTIN 4565)
Ph 07 5449 5200 Fax 07 5447 1062
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
8. Please provide amended plans incorporating the changes/modifications as discussed
with Council’s Manager Works Planning, Syd Jerram, namely:
A. The inclusion of a pedestrian refuge and pram ramps to facilitate the crossing
of Pacific Avenue in front of the proposed development.
B. The use of yellow ‘NSAT’ lines (on Drawing 2384-01-009) instead of signs.
C. The inclusion of better detail about the connection of the proposed edge lines
to the existing line marking on Drawing 2384-01-009.
D. The use of ‘A’ size signs only – Note 2 on Drawing 009 refers.
E. The deletion of Note 3 on Drawing 009, with regards to the MUTCD.
F. The deletion of Note 7 on Drawing 009, i.e., guideposts are not to be used.
G. The removal of the “outside” edge line along the bikeway, including the
turnout to the development.
9. Please provide a plan showing the width of easements, as required by Conditions 43
and 47 of the Court Order dated 5 March 2008.
10. Please amend the note on the “Pavement Widening Detail” on Drawings No 2384-01-
004 and 005 to read: Provide subsoil drains to kerb in accordance with NSC Std Drg
9205.
11. Please amend the note on the “Pavement Widening Detail” on Drawings No 2384-01-
004 and 005 to read: Existing pavement to be saw-cut back 300mm to provide a clean
face for the new pavement.
12. With regards to the Pavement Design shown on Drawings No 2384-01-004 and 005,
please provide 35mm (min) AC Surfacing.
13. With regards to the Pavement Design shown on Drawings No 2384-01-004 and 005,
please amend the Design ESA to read: 3 x 105, in accordance with Noosa Planning
Scheme Policy 5.
14. Please amend the note on the “Concrete Pathway Details” on Drawing No 2384-01-
005 to read: 2% Desirable Crossfall, 2.5% Maximum.
Kevin Slender
Technical Assessment Officer
IMPORTANT AND LEGAL PRIVILEGE NOTICE:
The information contained in this facsimile message is CONFIDENTAL and may be subject to legal privilege. If you are not
the intended recipient, you are notified that any use of this message is prohibited. If you received this message in error,
please notify us immediately by telephoning 07 54495200 and destroy the original.
Page: 2 of 2
Original to follow: No
Sunshine Coast Regional Council Tewantin Office 9 Pelican Street TEWANTIN (PO Box 141 TEWANTIN 4565)
Ph 07 5449 5200 Fax 07 5447 1062