Council archive · source document
Appendix H - SDAP Response · REC15/0011
Attached to the e-mail REC15/0011 - Development Application for Reconfiguration of a lot - 1 lot into 11 lots plus balance lot - Appendices F, G, H & I email 2 of 2.
Performance outcomes Acceptable outcomes Response Comment
sediment of a suitable quality and type from outside
the active beach system, or
(2) the construction of an erosion control structure,
where it is demonstrated that installing an erosion
control structure is the only feasible option for
protecting permanent structures from coastal erosion
and those structures cannot be abandoned or
relocated in the event of coastal erosion occurring.
Editor’s note: Applications for coastal protection work should be
supported by a report certified by a Registered Professional
Engineer of Queensland (RPEQ) that demonstrates how the
engineering solution sought by the work will be achieved.
Editor’s note: Applications for erosion control structures should
demonstrate the consideration of beach nourishment techniques,
and include a statement of why nourishment (in whole or part)
has not been adopted as the preferred means of controlling the
erosion risk.
AND
AO5.5 Development involving reclamation: N/A The proposed development does not include reclamation.
(1) does not alter, or otherwise minimises impacts on,
the physical characteristics of a waterway or the
seabed near the reclamation, including flow regimes,
hydrodynamic forces, tidal water and riverbank
stability
(2) is located outside the active sediment transport area,
or otherwise maintains sediment transport processes
as close as possible to their natural state
(3) ensures activities associated with the operation of the
development maintain the structure and condition of
vegetation communities and avoid wind and water
run-off erosion.
Editor’s note: Applications for reclamation should be supported
by a report certified by an RPEQ that demonstrates how the
engineering solutions sought by the work will be achieved
PO6 Erosion prone areas in a coastal AO6.1 Development locates built structures outside the Refer response to AO1.1 above.
management district are maintained as part of the coastal management district that is the erosion
development free buffers, or where prone area unless the development is listed under AO1.1
permanent buildings or structures exist, (1) – (5).
coastal erosion risks are avoided or AND
mitigated.
AO6.2 Development is located outside the erosion prone
State development assessment provisions Module 10 — Coastal protection 10.1 Tidal works, or development in a coastal management district state code
20 June 2014 V1.4 Page 5 of 16
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix H - SDAP Response.pdfRelated documentApplication case desk ↗
About this file
- File size
- 87 KB (small file)
- File type
No other editions are linked here.