                 SPECIFIC OUTCOMES                                             PROBABLE SOLUTIONS                              COMPLIANCE                      COMMENTS
and shower/change rooms.                                       S31.2 Secure and convenient parking space for bicycles is          YES       Provision for secure and convenient bicycle parking
                                                               provided on site in accordance with AS2890.3 Bicycle                         spaces will be provided on-site in accordance with
                                                               Parking Facilities and Figure 14-1 Minimum Requirements                      AS2890.3. Please condition any future
                                                               for Bicycle Parking;
                                                                                                                                            development permit accordingly.
                                                               AND
                                                               S31.3 Where at least 5 bicycle parking spaces are required         YES
                                                               in accordance with Figure 14-1 Minimum Requirements for                      Bicycle parking spaces will be provided in
                                                               Bicycle Parking, end-of-trip cycle facilities are provided at                accordance with S31.3. Please condition any future
                                                               the following rate:                                                          development permit accordingly.
                                                               a) 1 locker per 2 bicycle parking spaces; and
                                                               b) 1 shower cubicle with ancillary change rooms per 10
                                                               bicycle spaces or part thereof;
                                                               AND
                                                               S31.4 Bicycle parking spaces and cyclist facilities are            YES       Bicycle parking spaces will be designed in
                                                               designed in accordance with AUSTROADS Guide to Traffic
                                                               Engineering Practice, Part 14 – Bicycles, Section 10;                        accordance with S31.4. Please condition any future
                                                               AND                                                                          development permit accordingly.

                                                               S31.5 On-site pedestrian facilities such as seating and            YES       The proposed development will provide sufficient
                                                               shade structures are provided in developments for the                        seating and shade facilities.
                                                               convenience of persons walking to the site.
Site facilities                                                32.1 Waste storage areas, external storage areas and               YES       Waste storage areas, external storage areas and
O32 Waste storage areas, external storage areas and            loading docks are situated to the rear of the building or                    loading docks, are situated at the rear and within
loading docks do not detract from the visual amenity of        under the ground;                                                            the proposed building (refer to proposal plans
the streetscape or cause nuisance to adjoining                 OR
properties.                                                                                                                                 prepared by Zenith Design within Appendix I).

                                                                                                                                            Any external waste storage areas, external storage
                                                               S32.2 With the exception of the access way, waste storage          YES       areas and loading docks, not located at the rear or
                                                               areas, external storage areas and loading docks are                          within the building, will be visually screened by
                                                               visually screened by landscaping or fencing.
                                                                                                                                            landscaping or fencing. Please condition any future
                                                                                                                                            development permit accordingly.
Environment & heritage values                                  No solution provided                                               YES       The proposed extension will not result in significant
O33 There are no significant adverse effects on the                                                                                         adverse effects on the biodiversity, natural
biodiversity, natural vegetation, native wildlife, habitats,   Advisory note                                                                vegetation, native wildlife, habitats, landscape
landscape quality, water quality or heritage values,           PSP24 – Effluent Disposal details requirements for the
including those related to—                                    design and siting of effluent disposal systems where                         quality, water quality or heritage values in
a) changes to natural drainage;                                located outside a sewerage service area. Compliance with                     accordance with the approved development.

Used in these records

About this file

File size
8.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

MCU14_0073 Town Planning Report.pdf · 8.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.