Skip to the record
The gold standard in government transparency.

Original source · versioned page text

F - Code Response Tables

of 31

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Property
Projects
Australia

 

accommodation units by locating noise sensitive
spaces such as bedrooms away from noise
generating areas of the development, such as
carparking areas or mechanic plant and equipment
or recreational facilities.

the driveway and car parking areas of adjoining
buildings.

 

Mechanical Plant and Equipment
010

Mechanical plant and equipment associated with
residential uses are designed and located so as not
have an adverse impact on the visual amenity of
the site or surrounding areas.

S10.1

Mechanical plant and equipment, including pool and spa
pumps, pool heaters, air conditioning units and
refrigeration units are:

a. where located at ground level, screened by fencing
15m in height or dense vegetation of at least 1.5m in
width incorporating grouped trees and shrubs with
maximum separation distance of 1m measured from
the centre of the plant; and

b. for Multiple Housing Type 2, 3 and 4 are visually
integrated into the line and plane of the building and
roof design and do not project beyond the height or
width of the building when viewed from the street
and adjoining properties.

Complies (S10.1)

A condition of any subsequent development
approval will require mechanical plant and
equipment be installed in accordance with
specific outcome S10.1 of the Residential Uses
Code.

 

 

Ancillary Recreation Uses
Oll

Ancillary recreation uses, such as outdoor tennis
courts and half netball courts, do not have an
adverse effect on the amenity enjoyed by users of
adjacent or nearby premises nor do they cause

 

S111

If the use involves ancillary use of outdoor courts
including tennis courts, half courts and netball courts—the
use complies with the requirements in Section 2 of
Planning Scheme Policy 8 — Tennis and Other Courts;

AND

 

Not Applicable (S11.1)

The proposed development does not involve any
ancillary outdoor courts, including a tennis court.

 

Toowoomba
PO Box 3686, Toowoomba Qld 4350
Phone: 07 4632 0516

Email: [email protected]

Brisbane
PO Box 1264, New Farm Qld 4005,
Phone: 07 3254 1566

Propertyprojectsaustralia.com.au

 
Log in to download the original file

F - Code Response Tables.pdf · 3.0 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.