NOOSA COUNCIL APPROVED PLAN MCU22/0172, OPW22/0243 & RAL22/0024 Curved Roof Ridge RL32.67 25 JANUARY 2023 Gutter RL30.78 Gutter RL30.98 Roof RL27.86 CP BUP13731 52°55'20" CP 34.782 BUP3942 G R A N T 90 UNIT 2 RP92518 142°55'20" 17.099 322°55'20" 17.099 S T R E E T UNIT 1 CP BUP5714 Gutter RL25.19 232°55'20" CP 34.782 BUP11507 Gutter RL29.92 Ridge RL26.8 Ridge RL32.15 PROPOSED DEVELOPMENT USE Multiple Dwellings (Duplex) SITE AREA 594.37m2 MAX SITE COVER (40%) 237.74m2 PROPOSED SITE COVER 228.5m2 or 38.44% Gross Floor Area GROUND LEVEL UNIT 1 52.89 UNIT 2 52.89 105.78 m² LEVEL 1 UNIT 1 65.10 UNIT 2 65.10 130.20 m² 235.98 m² B L A C K Grant Street Duplex Project No. Drawing No. Use figured dimensions in Contact information: preference to scale. All dimensions to be varified and checked on site. PO Box 781 Tewantin Q 4565 PROPOSED SITE PLAN 202307 DA1.05 These designs, drawings, Architect Registration # 5386 QLD For Molti Partnerships W O O D specifications and the copyright thereof are the property of Ph: 0416 037 424 22 Grant Street, Noosa Heads QLD 4567 Scale Blackwood and must not be used, [email protected] Date Revision retained or copied without the 1:200, 1:1 @ A3 written authority of Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au 9/01/2023 RFI#3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of pages 2 to 23 (of 24)
Page 2
Gutter RL30.78
21.38
NOOSA COUNCIL
Curved Roof Ridge RL32.67
APPROVED PLAN
MCU22/0172, OPW22/0243 &
RAL22/0024
Gutter RL30.98
21.51
Roof RL27.86
25 JANUARY 2023
BU
P3
94
2
C
CP N 52°55'20"
BUP13731 34.782
+22.30
+21.85
+22.75
+23.20
26
Back of Kerb
BINS
+21.40
1500 setback
A: 2.4 m2 6000 setback 2000 setback
2500 setback
store 6000 setback 1500 setback
DOUBLE GARAGE
STORE
21.36
A: 39.6 m2 A
+21.40 A: 11.1 m2
6,000 Distance: CONCRETE
+21.51
5.96 m
DRIVEWAY
CONCRETE vb wm dr
21.20
cellar
IL19.82
375dia
LOBBY E
142°55'20"
WATER STAIR
17.099
DENTENTION +21.38
A: 7.7 m 2
+21.55
TANK
CROSSOVER
21.08
LOT 90 LOBBY STAIR
A: 7.7 m2
W
cellar
vb wm dr
322°55'20"
+21.52 DOUBLE GARAGE
17.099
DRIVEWAY A: 39.6 m2
CONCRETE CONCRETE STORE
B A: 11.1 m2 B
21.01
store 1500 setback
2000 setback
A: 2.4 m2
Hyd +21.40
2500 setback
+23.35
+21.85
+22.30
+22.75
BINS
Pit
1500 setback
25
Telstra
24
Water Meter
27
20
22 CP
.9
8 23
BUP5714
Power pole CP 232°55'20"
Gutter RL25.19
BUP11507 S 34.782
Water Meter C
21
21.19
Gutter RL29.92
B L A C K Grant Street Duplex
Project No. Drawing No.
Use figured dimensions in
Contact information:
preference to scale. All dimensions
to be varified and checked on site. PO Box 781 Tewantin Q 4565 BASEMENT 202307 DA2.01
These designs, drawings,
Architect Registration # 5386 QLD
For Molti Partnerships
W O O D
specifications and the copyright
thereof are the property of Ph: 0416 037 424
22 Grant Street, Noosa Heads QLD 4567
Scale
Blackwood and must not be used,
[email protected] Date Revision
retained or copied without the 1:100 @ A3
written authority of Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au 9/01/2023 RFI#3
Page 3
Gutter RL30.78
21.38
NOOSA COUNCIL
Curved Roof Ridge RL32.67
APPROVED PLAN RFI#3 - REMOVE PLANTERS AND SOLID
MCU22/0172, OPW22/0243 & BALUSTRADES. ADD LIGHT BALUSTRADES TO
RAL22/0024 HELP EXPRESS GROUND FLOOR BALCONY AND
Gutter RL30.98
21.51
Roof RL27.86
25 JANUARY 2023 REDUCE IMPACT TO THE STREET.
BU
P3
94
2
C
CP N 52°55'20"
BUP13731 22 23 24 25 34.782 27
Distance:
+24.70 gate
1.53 m
26
+23.20
+23.80
Back of Kerb
+24.10
+24.65
gate +24.80 +26.20
STAIR gate
garden garden
Distance:
1.19 m
P
P P P
P P
CONCRETE +24.70 POOL
21.36
+24.40 +24.80 3M x 4M
Distance:
pool deck
A
DINING TERRACE
2.61 m
A: 13.6 m2 A: 17.5 m2 A: 12.2 m2
Distance: s CONCRETE
CONCRETE
6.71 m BAL1
KITCHEN
+24.80
gate
A: 13.6 m2
LIVING
ptry ct rf
A: 22.4 m2 DRY / SERVICES
IL19.82
A: 3.1 m2
A: 9.8 m2
375dia
fireplace E
142°55'20"
BBQ
17.099
raised floor
TF
WC
P ac ac
LOT 90
A: 3.1 m2
P ac ac
raised floor BBQ
21.08
WC
fireplace TF
W DRY / SERVICES
gate
ptry ct rf A: 8.3 m2
LIVING
KITCHEN
A: 22.4 m2 TERRACE
A: 13.6 m2 DINING
322°55'20"
17.099
BAL2 s A: 13.6 m 2 A: 16.5 m2
CONCRETE
CONCRETE POOL
3M x 4M
+24.40 +24.50 +24.80
B A: 12.2 m2 pool deck
B
CONCRETE
P P
21.01
P P P
P
garden garden +24.65
+24.10
Hyd +24.70
gate
+23.65
STAIR gate +24.80 +26.20
+23.35
Telstra Pit
25
20
22 23 24 26 27 CP
.9
8 gate
BUP5714
Di .94
sta m
6
Power pole CP 232°55'20"
nc
Gutter RL25.19
e:
BUP11507 S 34.782
C
21
21.19
Gutter RL29.92
B L A C K Grant Street Duplex
Project No. Drawing No.
Use figured dimensions in
Contact information:
preference to scale. All dimensions
to be varified and checked on site. PO Box 781 Tewantin Q 4565 GROUND FLOOR 202307 DA2.02
These designs, drawings,
Architect Registration # 5386 QLD
For Molti Partnerships
W O O D
specifications and the copyright
thereof are the property of Ph: 0416 037 424
22 Grant Street, Noosa Heads QLD 4567
Scale
Blackwood and must not be used,
[email protected] Date Revision
retained or copied without the 1:100 @ A3
written authority of Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au 9/01/2023 RFI#3
Page 4
NOOSA COUNCIL
APPROVED PLAN
MCU22/0172, OPW22/0243 &
RAL22/0024
25 JANUARY 2023
C
N
Distance:
2.96 m
2,905
scrn01 scrn01
vb Robe
wc
scrn01
ENSUITE BED 3
A: 7.7 m2 A
A: 12.1 m2
void BED 2
Pergola A: 11.2 m2
12,530 7,362
BED 1
scrn01
Robe
A: 17.1 m2
PASSAGE +28.10
BATH
vb
A: 9.5 m 2
A: 5.2 m2
E
WC
Linen
scrn01
wc
Robe
A: 2.4 m2
scrn01
Robe
WC
Linen
wc
BATH
A: 2.4 m2
W A: 5.2 m2
PASSAGE +28.10
vb
A: 9.5 m2
BED 1 Robe
A: 17.1 m2 BED 2
Pergola
13,530 A: 11.2 m2 6,362
void
BED 3
B ENSUITE B
scrn01
A: 7.7 m2 A: 12.1 m2
wc
vb Robe
scrn01 scrn01
2,904
S
C
B L A C K Grant Street Duplex
Project No. Drawing No.
Use figured dimensions in
Contact information:
preference to scale. All dimensions
to be varified and checked on site. PO Box 781 Tewantin Q 4565 LEVEL 01 202307 DA2.03
These designs, drawings,
Architect Registration # 5386 QLD
For Molti Partnerships
W O O D
specifications and the copyright
thereof are the property of Ph: 0416 037 424
22 Grant Street, Noosa Heads QLD 4567
Scale
Blackwood and must not be used,
[email protected] Date Revision
retained or copied without the 1:100 @ A3
written authority of Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au 9/01/2023 RFI#3
Page 5
NOOSA COUNCIL
APPROVED PLAN
MCU22/0172, OPW22/0243 &
RAL22/0024
25 JANUARY 2023
C
N
2,905
12,530 7,362 A
METAL ROOF
SHEETING
Fall 3 deg
E
PARTY WALL box gutter
W
METAL ROOF
SHEETING
Fall 3 deg
13,530 6,362
B B
2,904
S
C
B L A C K Grant Street Duplex
Project No. Drawing No.
Use figured dimensions in
Contact information:
preference to scale. All dimensions
to be varified and checked on site. PO Box 781 Tewantin Q 4565 ROOF 202307 DA2.04
These designs, drawings,
Architect Registration # 5386 QLD
For Molti Partnerships
W O O D
specifications and the copyright
thereof are the property of Ph: 0416 037 424
22 Grant Street, Noosa Heads QLD 4567
Scale
Blackwood and must not be used,
[email protected] Date Revision
retained or copied without the 1:100 @ A3
written authority of Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au 9/01/2023 RFI#3
Page 6
NOOSA COUNCIL MATERIALS & COLOUR LEGEND
APPROVED PLAN
BAL1 Aluminium powdercoated battens
MCU22/0172, OPW22/0243 &
BAL2 Clear Glass Panels
RAL22/0024
BR Rosenberg Bricks
25 JANUARY 2023
FC Fibre cement cladding paint finish
scn1 SHS aluminium battens
RS Selected Roof sheeting
R1 Rendered Blockwork - Timeless Grey
R2 Rendered Blockwork - Concrete Look
R3 Rendered Blockwork - Casper White
VC1 Vertical cladding - Timeless Grey
VC2 Vertical cladding - Timber Look
8M BUILDING HEIGHT LIMIT RFI#3 - ADD FFL'S TO ILLUSTRATE COMPLIANCE WITH HEIGHT
RESTRICTIONS
R1
R1
PRIVACY SCREEN
VC1 scrn01
VC1 scrn01
VC1
1 LEVEL 1
+28.10
R3 R1
PARTY WALL
POOL BBQ FFL
SCRN01
DRIVEWAY
R2
0 GROUND LEVEL R2 R2
+24.80
1,000
ENTRY NGL
GATE
REFUSE
DRIVEWAY
BR
-1 BASEMENT
+21.40
B L A C K Grant Street Duplex
Project No. Drawing No.
Use figured dimensions in
Contact information:
preference to scale. All dimensions
to be varified and checked on site. PO Box 781 Tewantin Q 4565 NORTH ELEVATION 202307 DA3.01
These designs, drawings,
Architect Registration # 5386 QLD
For Molti Partnerships
W O O D
specifications and the copyright
thereof are the property of Ph: 0416 037 424
22 Grant Street, Noosa Heads QLD 4567
Scale
Blackwood and must not be used,
[email protected] Date Revision
retained or copied without the 1:100 @ A3
written authority of Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au 9/01/2023 RFI#3
Page 7
NOOSA COUNCIL MATERIALS & COLOUR LEGEND
APPROVED PLAN
BAL1 Aluminium powdercoated battens
MCU22/0172, OPW22/0243 &
BAL2 Clear Glass Panels
RAL22/0024
BR Rosenberg Bricks
25 JANUARY 2023
FC Fibre cement cladding paint finish
scn1 SHS aluminium battens
RS Selected Roof sheeting
R1 Rendered Blockwork - Timeless Grey
R2 Rendered Blockwork - Concrete Look
R3 Rendered Blockwork - Casper White
VC1 Vertical cladding - Timeless Grey
VC2 Vertical cladding - Timber Look
8M BUILDING HEIGHT LIMIT RFI#3 - ADD FFL'S TO ILLUSTRATE COMPLIANCE WITH HEIGHT
RESTRICTIONS
scrn01 VC1 scrn01 scrn01
VC1 scrn01
NGL
1 LEVEL 1 RETAINING WALL RETAINING WALL
+28.10
P
PARTY WALL P
scrn01 R1 R1
0 GROUND LEVEL
+24.80
-1 BASEMENT
+21.40
B L A C K Grant Street Duplex
Project No. Drawing No.
Use figured dimensions in
Contact information:
preference to scale. All dimensions
to be varified and checked on site. PO Box 781 Tewantin Q 4565 EAST ELEVATIONS 202307 DA3.02
These designs, drawings,
Architect Registration # 5386 QLD
For Molti Partnerships
W O O D
specifications and the copyright
thereof are the property of Ph: 0416 037 424
22 Grant Street, Noosa Heads QLD 4567
Scale
Blackwood and must not be used,
[email protected] Date Revision
retained or copied without the 1:100 @ A3
written authority of Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au 9/01/2023 RFI#3
Page 8
NOOSA COUNCIL MATERIALS & COLOUR LEGEND
APPROVED PLAN
BAL1 Aluminium powdercoated battens
MCU22/0172, OPW22/0243 &
BAL2 Clear Glass Panels
RAL22/0024
BR Rosenberg Bricks
25 JANUARY 2023
FC Fibre cement cladding paint finish
scn1 SHS aluminium battens
RS Selected Roof sheeting
R1 Rendered Blockwork - Timeless Grey
R2 Rendered Blockwork - Concrete Look
R3 Rendered Blockwork - Casper White
VC1 Vertical cladding - Timeless Grey
VC2 Vertical cladding - Timber Look
RFI#3 - ADD FFL'S TO ILLUSTRATE COMPLIANCE WITH HEIGHT
RESTRICTIONS
8M BUILDING HEIGHT LIMIT Window Shroud
R1
VC1
VC1 VC1
scrn01
scrn01
PRIVACY SCREEN
Pergola
1 LEVEL 1
+28.10
R1
FFL R1
scrn01
BBQ POOL
Distance:
1.21 m
NGL R2
R2
R2
0 GROUND LEVEL
+24.80 ENTRY
1,000
GATE
Refuse
DRIVEWAY
943
-1 BASEMENT
+21.40
B L A C K Grant Street Duplex
Project No. Drawing No.
Use figured dimensions in
Contact information:
preference to scale. All dimensions
to be varified and checked on site. PO Box 781 Tewantin Q 4565 SOUTH ELEVATION 202307 DA3.03
These designs, drawings,
Architect Registration # 5386 QLD
For Molti Partnerships
W O O D
specifications and the copyright
thereof are the property of Ph: 0416 037 424
22 Grant Street, Noosa Heads QLD 4567
Scale
Blackwood and must not be used,
[email protected] Date Revision
retained or copied without the 1:100 @ A3
written authority of Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au 9/01/2023 RFI#3
Page 9
NOOSA COUNCIL MATERIALS & COLOUR LEGEND
APPROVED PLAN
BAL1 Aluminium powdercoated battens
MCU22/0172, OPW22/0243 &
BAL2 Clear Glass Panels
RAL22/0024
BR Rosenberg Bricks
25 JANUARY 2023
FC Fibre cement cladding paint finish
scn1 SHS aluminium battens
RS Selected Roof sheeting
R1 Rendered Blockwork - Timeless Grey
R2 Rendered Blockwork - Concrete Look
R3 Rendered Blockwork - Casper White
VC1 Vertical cladding - Timeless Grey
VC2 Vertical cladding - Timber Look
RFI#3 - ADD FFL'S TO ILLUSTRATE COMPLIANCE WITH HEIGHT
RESTRICTIONS. REMOVE PLANTERS AND SOLID BALUSTRADES.
ADD LIGHT BALUSTRADES TO HELP EXPRESS GROUND FLOOR
BALCONY AND REDUCE IMPACT TO THE STREET. INTRODUCE
FASCIA TO SUBTRACT FROM BOX BUILDING FORM.
LINE OF FASCIA LINE OF FASCIA
scrn01
scrn01
1 LEVEL 1
+28.10
0 GROUND LEVEL BAL1 scrn01
BAL2
+24.80 VC2 scrn01 VC2
R2
VC2
DRIVEWAY
BR BR
-1 BASEMENT
+21.40
B L A C K Grant Street Duplex
Project No. Drawing No.
Use figured dimensions in
Contact information:
preference to scale. All dimensions
to be varified and checked on site. PO Box 781 Tewantin Q 4565 WEST ELEVATION 202307 DA3.04
These designs, drawings,
Architect Registration # 5386 QLD
For Molti Partnerships
W O O D
specifications and the copyright
thereof are the property of Ph: 0416 037 424
22 Grant Street, Noosa Heads QLD 4567
Scale
Blackwood and must not be used,
[email protected] Date Revision
retained or copied without the 1:100 @ A3
written authority of Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au 9/01/2023 RFI#3
Page 10
NOOSA COUNCIL MATERIALS & COLOUR LEGEND
APPROVED PLAN
BAL1 Aluminium powdercoated battens
MCU22/0172, OPW22/0243 &
BAL2 Clear Glass Panels
RAL22/0024
BR Rosenberg Bricks
25 JANUARY 2023
FC Fibre cement cladding paint finish
scn1 SHS aluminium battens
RS Selected Roof sheeting
R1 Rendered Blockwork - Timeless Grey
R2 Rendered Blockwork - Concrete Look
R3 Rendered Blockwork - Casper White
VC1 Vertical cladding - Timeless Grey
VC2 Vertical cladding - Timber Look
8M BUILDING HEIGHT LIMIT
RFI#3 - REMOVE PLANTERS AND SOLID
BALUSTRADES. ADD LIGHT BALUSTRADES TO
HELP EXPRESS GROUND FLOOR BALCONY AND
REDUCE IMPACT TO THE STREET.
BED 3 BED 2 PASSAGE BED 1
2,700
1 LEVEL 1
+28.10
SCRN01
BBQ
3,000
DINING KITCHEN LIVING
POOL
0 GROUND LEVEL BAL1
+24.80
NGL
993
LAUNDRY GARAGE DRIVEWAY
-1 BASEMENT
+21.40
B L A C K Grant Street Duplex
Project No. Drawing No.
Use figured dimensions in
Contact information:
preference to scale. All dimensions
to be varified and checked on site. PO Box 781 Tewantin Q 4565 SECTION A 202307 DA4.01
These designs, drawings,
Architect Registration # 5386 QLD
For Molti Partnerships
W O O D
specifications and the copyright
thereof are the property of Ph: 0416 037 424
22 Grant Street, Noosa Heads QLD 4567
Scale
Blackwood and must not be used,
[email protected] Date Revision
retained or copied without the 1:100 @ A3
written authority of Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au 9/01/2023 RFI#3
Page 11
NOOSA COUNCIL
+31.40 APPROVED PLAN
MCU22/0172, OPW22/0243 &
RAL22/0024
25 JANUARY 2023
+28.10
+24.80
+23.75
+21.40
2 SECTION C
- Scale 1:200
RFI#3 - REMOVE PLANTERS AND SOLID
BALUSTRADES. ADD LIGHT BALUSTRADES TO
HELP EXPRESS GROUND FLOOR BALCONY AND
REDUCE IMPACT TO THE STREET.
8M BUILDING HEIGHT LIMIT
PASSAGE
BED 1 BED 2 BED 3
1 LEVEL 1
+28.10
FIRE PLACE BBQ
LIVING KITCHEN DINING
0 GROUND LEVEL POOL
BAL2
+24.80
952
NGL
DRIVEWAY
CROSSOVER GARAGE LAUNDRY
-1 BASEMENT
+21.40
1 SECTION B
- Scale 1:100
B L A C K Grant Street Duplex
Project No. Drawing No.
Use figured dimensions in
Contact information:
preference to scale. All dimensions
to be varified and checked on site. PO Box 781 Tewantin Q 4565 SECTION B 202307 DA4.02
These designs, drawings,
Architect Registration # 5386 QLD
For Molti Partnerships
W O O D
specifications and the copyright
thereof are the property of Ph: 0416 037 424
22 Grant Street, Noosa Heads QLD 4567
Scale
Blackwood and must not be used,
[email protected] Date Revision
retained or copied without the 1:100, 1:200 @ A3
written authority of Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au 9/01/2023 RFI#3
Page 12
NOOSA COUNCIL
SITE COVER 231.0 m2
APPROVED PLAN
MCU22/0172, OPW22/0243 &
RAL22/0024
25 JANUARY 2023
GFA: 52.9
GFA: 52.9
1 SITE COVER 3 GFA GROUND LEVEL
- Scale 1:200 - Scale 1:200
Site Area 594.37m2 m2 Required Achieved
Site Cover 231m2 40% 38.86%
GFA: 65.2
GFA: 65.2
2 LANDSCAPING 4 GFA LEVEL 1
- Scale 1:200 - Scale 1:200
Site Area 594.37m2 m2 Required Achieved Site Area 594.37m2 m2 Required Achieved
Landscaped Area 239.1m2 40% 40.22% LOWER GFA 105.78m2
Hard landscape 66m2 [40%] [27.60%] UPPER GFA 130.20m2
Soft landscaping 173.1m2 [60%] [72.39%] Combined GFA 235.98m2 40 % 39.7 %
B L A C K Grant Street Duplex
Project No. Drawing No.
Use figured dimensions in
Contact information:
preference to scale. All dimensions
to be varified and checked on site. PO Box 781 Tewantin Q 4565 SITE COVER & GFA 202307 DA5.01
These designs, drawings,
Architect Registration # 5386 QLD
For Molti Partnerships
W O O D
specifications and the copyright
thereof are the property of Ph: 0416 037 424
22 Grant Street, Noosa Heads QLD 4567
Scale
Blackwood and must not be used,
[email protected] Date Revision
retained or copied without the 1:200, 1:1 @ A3
written authority of Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au 9/01/2023 RFI#3
Page 13
NOOSA COUNCIL EXTERNAL FINISHES
APPROVED PLAN
MCU22/0172, OPW22/0243 & CODE DESCRIPTION FINISH
RAL22/0024 BR Rosenberg Bricks Lang Mursten
25 JANUARY 2023
FC Hardies Axon FC Cladding 400mm Dulux - Timesless Grey GR23
PNT1 Paint Finish to all exterior walls Dulux - Timeless Grey GR23
RS Colorbond roof sheeting Colorbond TBA
VC1 Vertical Cladding Dulux - Timeless Grey GR23
VC2 Vertical Cladding Dulux - Timber Look
R1 Rendered Blockwork Similar toTimeless Grey
R2 Rendered Blockwork Concrete look
R3 Rendered Blockwork Similar to Casper White
INTERNAL FINISHES
CODE DESCRIPTION FINISH
CP Sisal Carpet TBC
JN1 Joinery Finish Chalk Finish Rural Oak
PNT2 Paint Finish to all internal walls + ceilings Dulux - Casper White
STN Smartstone Smartstone Tundra Grigio
TF Timber Look Flooring Oak White
TL2 Tile floor 600mm x 300mm TBC
TL3 Tile wall 100mm x 100mm TBC
VC1 Vertical Cladding Dulux - Timeless Grey GR23
VC2 Vertical Cladding TBC
PRIVACY & SCREENING
CODE DESCRIPTION FINISH
BAL1 RHS Aluminium Battens Timeless Grey GR23
BAL2 SHS Aluminium Battens With 5mm Gaps Timeless Grey GR23
BR PNT1 PNT2 JN1 PV CONC
SCN1 SHS Aluminium Battens Timeless Grey GR23
HARDSCAPE FINISHES
CODE DESCRIPTION FINISH
CONC Concrete finish - TBA Selected Clear Sealer
MDW Modwood decking TBC
PV Entry paving TBC
TL1 Black mosaic pool tile TBC
VC1 R1 TF VC2 MDW STN CP TL1 NATIVE VEGETATION
B L A C K Grant Street Duplex
Project No. Drawing No.
Use figured dimensions in
Contact information:
preference to scale. All dimensions
to be varified and checked on site. PO Box 781 Tewantin Q 4565 MATERIALS + FINISHES 202307 DA6.1
These designs, drawings,
Architect Registration # 5386 QLD
For Molti Partnerships
W O O D
specifications and the copyright
thereof are the property of Ph: 0416 037 424
22 Grant Street, Noosa Heads QLD 4567
Scale
Blackwood and must not be used,
[email protected] Date Revision
retained or copied without the NTS @ A3
written authority of Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au 9/01/2023 RFI#3
Page 14
NOOSA COUNCIL
APPROVED PLAN
MCU22/0172, OPW22/0243 &
RAL22/0024
25 JANUARY 2023
[OCR of page images]
| iS (Sd 3 a
FA 2
j ig ! Bi &I
a 5
cP Lown Looe 1
>
7 BUP13731 52°55'20" cP
34.782 BUP3942
. 4 in \ i)
= ; Shy
RP92 | | | =
a8
4 13¢
a 4] 33
wn / cP :
a! TT ~78 UNIT 1 ce
Az eh
Mm : cP
Pes +} BUPS714
Mm Cys
4 2 eke
N — Guter25.19 1 oe
iN / 3 cp .
iON 7 | BUP11507
! ‘\ Y ' Ro Gutter RLVIT Yh Proposed Commypnity Title Subdivision Plan
\ Di By JL 26/09"
| | Ridge ! | ‘\ vot tall services are qubject to change and will
: a "| ! | \ 7 | be accurately refif-cted in the Plan Sealing Application
| R268 | | \ !
> ! i 7 1
| | Soo gyrcoo :
' ® 1
NOOSA COUNCIL
APPROVED PLAN
MCU22/0172, OPW22/0243 &
RAL22/0024
25 JANUARY 2023
Page 15
S
W
NOOSA COUNCIL
S
APPROVED PLAN
W
MCU22/0172, OPW22/0243 &
RAL22/0024
S
25 JANUARY 2023
W
S
W
N
S
W
S
W
NEW CONNECTION TO S
EXISTING SEWER SERVICE
W
S
W
NEW TYPE 'B1' BARRIER
KERB TO REPLACE EXISTING
STORMWATER PIT
S
W
GRANT STREET
S
W
S
W
PROPOSED RESIDENTIAL DRIVEWAY TO
BE CONSTRUCTED IN ACCORDANCE
WITH IPWEA RS-049 & RS-050
S
W
1.5m WIDE FOOTPATH TO BE
S
CONSTRUCTED IN ACCORDANCE WITH
W
NSC STD DWG RS-065.
S
W
NEW STORMWATER INLET
S
PIT AND BARRIER KERB.
W
MATCH NEATLY TO EXISTING
LEVELS
S
W
NEW CONNECTION TO
EXISTING WATER SERVICE
S
W
S
W
S
W
W
W
NOTE:
EXCEPT WHERE NOTED ON PLAN AND ASSOCIATED DESIGN DRAWINGS, ALL
IN-GROUND SERVICES WITHIN THE PROPERTY BOUNDARY INCLUDING BUT NOT
LIMITED TO: STORMWATER DRAINAGE, SEWERAGE, WATER, GAS, ELECTRICAL
W
AND COMMUNICATIONS TO BE SAFELY BE DISCONNECTED, REMOVED FROM
SITE AND CAPPED OFF AT SITE BOUNDARY. CONTRACTOR TO ARRANGE ALL
NECESSARY APPLICATIONS AND PERMITS WITH THE RELEVANT AUTHORITIES.
SERVICES TO BE CAPPED IN ACCORDANCE WITH RELEVANT SERVICE
PROVIDER SPECIFICATIONS AND STANDARD DETAILS
W
CLIENT DETAILS: PROJECT ADDRESS: APPROVED BY: PROJECT NAME:
W
PROPOSED RESIDENTIAL DUPLEX
INTEGRA PARTNERSHIPS TITLE: STATUS:
22 GRANT STREET LAYOUT PLAN FOR APPROVAL - NOT FOR
W
© ABN 89 647 469 707
NOOSA HEADS, QLD, 4567 NATHAN WAGSTAFF CONSTRUCTION
75 NOOSA DRIVE RPEQ: 20693
01 09/11/2022 ISSUED FOR APPROVAL MVP NW NW SCALE:
NOOSA HEADS, QLD 4567 CPEng
+61 7 5211 1003 REV DATE DESCRIPTION DWN CHK APP
1:100 DATE: 06/12/2022
DRAWING NUMBER: PROJECT NUMBER: SHEET REV:
W
SIZE:
RECORCONSULTING.COM REVISIONS
DO NOT SCALE, IF IN DOUBT ASK
010 20220218 A1 01
Page 16
NOOSA COUNCIL
APPROVED PLAN
MCU22/0172, OPW22/0243 &
RAL22/0024
25 JANUARY 2023
N
CUT/FILL DEPTH RANGE
Lower_value Upper_value Colour
-0.9 to -1. M
-0.8 to -0.9 M
-0.7 to -0.8 M
-0.6 to -0.7 M
D C
021 021 -0.5 to -0.6 M
GRANT STREET
-0.4 to -0.5 M
-0.3 to -0.4 M
-0.2 to -0.3 M
B B -0.1 to -0.2 M
021 021
FL 24.8m AHD 0 to -.1 M
FL 21.4m AHD
0 to .1 M
0.1 to 0.2 M
0.2 to 0.3 M
0.3 to 0.4 M
0.4 to 0.50 M
0.5 to 0.6 M
FL 21.4m AHD FL 24.8m AHD
A A 0.6 to 0.7 M
021 021
0.7 to 0.8 M
0.8 to 0.9 M
0.9 to 1 M
D C
021 021
EARTHWORKS VOLUMES
EARTHWORKS VOLUMES FROM
EXISTING SURFACE TO DESIGN
SURFACE
CUT = 506m³
FILL = 30m³
BALANCE = 476m³
NOTE:
EXCEPT WHERE NOTED ON PLAN AND ASSOCIATED DESIGN
DRAWINGS, ALL IN-GROUND SERVICES WITHIN THE PROPERTY
BOUNDARY INCLUDING BUT NOT LIMITED TO: STORMWATER
DRAINAGE, SEWERAGE, WATER, GAS, ELECTRICAL AND
COMMUNICATIONS TO BE SAFELY BE DISCONNECTED, REMOVED
FROM SITE AND CAPPED OFF AT SITE BOUNDARY. CONTRACTOR TO
ARRANGE ALL NECESSARY APPLICATIONS AND PERMITS WITH THE
RELEVANT AUTHORITIES. SERVICES TO BE CAPPED IN
ACCORDANCE WITH RELEVANT SERVICE PROVIDER
SPECIFICATIONS AND STANDARD DETAILS
CLIENT DETAILS: PROJECT ADDRESS: APPROVED BY: PROJECT NAME:
PROPOSED RESIDENTIAL DUPLEX
INTEGRA PARTNERSHIPS TITLE: STATUS:
22 GRANT STREET BULK EARTHWORKS FOR APPROVAL - NOT FOR
© ABN 89 647 469 707
NOOSA HEADS, QLD, 4567 NATHAN WAGSTAFF LAYOUT PLAN CONSTRUCTION
75 NOOSA DRIVE RPEQ: 20693
SCALE:
NOOSA HEADS, QLD 4567 CPEng
+61 7 5211 1003 REV DATE DESCRIPTION DWN CHK APP
1:100 DATE: 06/12/2022
DRAWING NUMBER: PROJECT NUMBER: SHEET REV:
SIZE:
RECORCONSULTING.COM REVISIONS
DO NOT SCALE, IF IN DOUBT ASK
020 20220218 A1 01
Page 17
NOOSA COUNCIL
APPROVED PLAN
MCU22/0172, OPW22/0243 &
RAL22/0024
25 JANUARY 2023
STAIRS GARAGE GARAGE STAIRS
UNIT 2 UNIT 2 UNIT 1 UNIT 1
FFL 21.4 FFL 21.4
D BULK EARTHWORKS
- SECTION SCALE 1:100
STAIRS DINING DINING STAIRS
UNIT 2 UNIT 2 UNIT 1 UNIT 1
FFL 24.8 FFL 24.8
C BULK EARTHWORKS
- SECTION SCALE 1:100
PATH POOL
UNIT 2 UNIT 2
DRIVEWAY GARAGE DINING FFL 26.2
UNIT 2 UNIT 2
FFL 24.8 FFL 24.7
FFL 21.4 FFL 21.4
B BULK EARTHWORKS
- SECTION SCALE 1:100
PATH POOL
UNIT 1 UNIT 1
DRIVEWAY GARAGE DINING FFL 26.2
UNIT 1 UNIT 1
FFL 24.8 FFL 24.7
FFL 21.4 FFL 21.4
A BULK EARTHWORKS
- SECTION SCALE 1:100
CLIENT DETAILS: PROJECT ADDRESS: APPROVED BY: PROJECT NAME:
PROPOSED RESIDENTIAL DUPLEX
INTEGRA PARTNERSHIPS TITLE: STATUS:
22 GRANT STREET EARTHWORKS FOR APPROVAL - NOT FOR
© ABN 89 647 469 707
NOOSA HEADS, QLD, 4567 NATHAN WAGSTAFF LONGITUDINAL SECTIONS CONSTRUCTION
75 NOOSA DRIVE RPEQ: 20693
SCALE:
NOOSA HEADS, QLD 4567 CPEng
+61 7 5211 1003 REV DATE DESCRIPTION DWN CHK APP
AS INDICATED DATE: 06/12/2022
DRAWING NUMBER: PROJECT NUMBER: SHEET REV:
SIZE:
RECORCONSULTING.COM REVISIONS
DO NOT SCALE, IF IN DOUBT ASK
021 20220218 A1 01
Page 18
NOOSA COUNCIL LEGEND
APPROVED PLAN
MCU22/0172, OPW22/0243 & SW SW PROPOSED STORMWATER DRAINAGE
RAL22/0024 PROPOSED GRATE
25 JANUARY 2023
PROPOSED FIELD INLET PIT
PROPOSED STORMWATER TANK
DRAINAGE NOTES
1. REFER HYDRAULIC DRAWINGS FOR BUILDING DRAINAGE DETAILS.
BU CP 2. ALL ROADWORKS AND DRAINAGE (EXTERNAL TO SITE BOUNDARIES
P1 AND/OR COUNCIL OWNED DRAINAGE PIPES INTERNAL TO THE SITE
37 BOUNDARIES) CONSTRUCTION AND TESTING TO BE IN ACCORDANCE
WITH NOOSA SHIRE COUNCIL DEVELOPMENT GUIDELINES, DRAWINGS
3 1 AND SPECIFICATIONS.
3. ALL DRAINAGE CONSTRUCTION (PRIVATELY OWNED DRAINAGE LINES
INTERNAL TO THE SITE BOUNDARIES) CONSTRUCTED AND TESTED TO
DEMOLISH EXISTING STORMWATER BE IN ACCORDANCE WITH RELEVANT AUSTRALIAN STANDARDS.
PIT END REMOVE APPROX 8m OF 4. ALL STORMWATER DRAINAGE PIPES INTERNAL TO SITE SHALL BE: Ø225
REDUNDANT PIPE. REINSTATE
KERB TO MATCH EXISTING SW SW SW SW SW SW RRJ RCP OR APPROVED EQUIVALENT.
SW 7. ALL STORMWATER PIPES ARE TO BE MANUFACTURED TO RELEVANT
SW AUSTRALIAN STANDARDS INCLUDING BUT NOT LIMITED TO AS4058 AND
SW
SW AS1992.
8. STORMWATER DRAINAGE AND STRUCTURES HAVE BEEN DESIGNED
FOR OPERATIONAL LOADS ONLY. CONTRACTOR TO CONSIDER
CONSTRUCTION LOADINGS AND ENSURE NO EXCESSIVE LOADS ARE
PLACED ON STORMWATER DRAINAGE OR STRUCTURES.
SW
0.5
9. CONTRACTOR TO CONFIRM LOCATION AND LEVEL OF EXISTING
0.25
STORMWATER DRAINAGE WHERE CONNECTING ON TO EXISTING.
10. CONTRACTOR TO NOTIFY THE SUPERINTENDENT OF ANY UNSUITABLE
FOUNDING MATERIAL WITHIN DRAINAGE TRENCH OR STORMWATER
SW
STRUCTURES AND AWAIT DIRECTION PRIOR TO LAYING OF PIPES.
11. ALL STORMWATER GRATES/LIDS WITHIN TRAFFICABLE AREAS TO BE
CLASS "D" IN ACCORDANCE WITH AS3996.
12. ALL GRATES AND LIDS SHALL SIT FLAT WITH ITS SURROUND AND NOT
BE LOOSE OR MOVE UNDER WHEEL LOADS.
5
13. ALL STORMWATER STRUCTURES TO BE CONSTRUCTED IN
SW
ACCORDANCE WITH PROJECT SPECIFICATION, AND LOCAL AUTHORITY
SW
GUIDELINES AND SPECIFICATIONS. WHERE STRUCTURES EXCEED
BU
MAXIMUM DEPTH AS IDENTIFIED WITHIN STANDARD DRAWINGS THE
CP
SW
CONTRACTOR WILL ENSURE AN ADEQUATE STRUCTURAL DESIGN IS
P5
1.3
0.5
UNDERTAKEN FOR THE SUBJECT STRUCTURE TO BE CONSTRUCTED
71
SW
TO.
SW
4 14. CONTRACTOR TO ENSURE ALL MANHOLE STRUCTURES COMPLY WITH
THE MAXIMUM DEPTH SPECIFIED IN THE PROJECT SPECIFICATION OR
2
SW LOCAL AUTHORITY FROM FINISHED SURFACE LEVEL TO UNDERSIDE OF
SW
SW
ROOF SLAB. ANY NON CONFORMANCE IS TO BE RECTIFIED AT THE
1
CONTRACTORS EXPENSE.
SW
0.4
SW SW SW SW SW SW SW 15. ALL FOOTPATHS TO BE CONSTRUCTED IN ACCORDANCE WITH
ARCHITECTURAL/LANDSCAPING DRAWINGS AND RELEVANT
AUTHORITY STANDARD DRAWINGS AND SPECIFICATIONS. FOOTPATHS
TO BE CONSTRUCTED WITH MAXIMUM 2.5% CROSSFALL. SHOULD
CONSTRUCTED FOOTPATHS EXCEED 2.5% CROSSFALL, THE
PROVIDE HUMES STORMTRAP OR
EQUIVALENT OSD WITH MIN. 6000L STORAGE
CONTRACTOR WILL BE REQUIRED TO RECTIFY BY REMOVING AND
REPLACING AT THEIR COST.
EXISTING Ø375mm SW PIPE OUTLET 16. CONCRETE FOOTPATH TO BE 100mm THICK N32 WITH SL72 MESH IN
USIL: 19.76 ACCORDANCE WITH NSC STD DWG RS-065, AS1679 AND AS3600 UNO
DSIL: 19.49
LENGTH: 35m
17. THE CONTRACTOR IS TO CONFIRM THE LOCATION AND DEPTH OF ALL
GRADE: 0.75% SERVICE CONDUITS IN VERGE PRIOR TO COMMENCING WORKS. THE
PROVIDE NEW ON GRADE LIP IN LINE STORMWATER
SUPERINTENDANT IS TO BE NOTIFIED OF ANY CONFLICTS WITH WORKS
INLET PIT AS PER NSC STD DWG DS-061 TO DS-063. IDENTIFIED IN THESE PLANS IMMEDIATELY.
MAKE SMOOTH JOIN TO EXISTING Ø375 SW PIPE 18. ALL TRENCH EXCAVATION AND CONSTRUCTION SHALL COMPLY WITH
SL: 21.01 THE REQUIREMENTS OF THE QUEENSLAND WORKPLACE HEALTH AND
IL: 19.76
SAFETY ACT 2011.
19. REMOVE ANY REDUNDANT DRAINAGE OUTLETS FROM THE KERB AND
CHANNEL INCLUDING ANY ASSOCIATED PIPEWORK ACROSS THE
FOOTWAY AND REINSTATE THE KERB AND CHANNEL AND THE
FOOTWAY AREA IN ACCORDANCE WITH COUNCIL GUIDELINES.
20.ROADBASE MATERIAL SHOULD BE PLACED IN LAYERS AT LEAST 75 MM
THICK BUT NOT EXCEEDING 150 MM IN THICKNESS, AND COMPACTED
TO A MINIMUM DENSITY OF 95% OF THE MAXIMUM DRY DENSITY AS
DETERMINED IN ACCORDANCE WITH AUSTRALIAN STANDARD
AS1289.6.2.
21. CONTRACTOR TO UNDERTAKE ROADWORKS TESTING IN ACCORDANCE
WITH NOOSA SHIRE COUNCIL GUIDELINES, DRAWINGS AND
SPECIFICATIONS.
22.INTERNAL CONCRETE TO BE 125MM THICK (EXCLUDING FINISHED
TREATMENTS) N32 IN ACCORDANCE WITH AS1379 AND AS3600. SL72
MESH MIN 50MM TOP COVER TO AS1304. MIN 100MM BASE COURSE
WHERE SUBGRADE CBR <=6. LOCATION AND TYPE OF INTERNAL
CONCRETE JOINTS TO CONFORM TO STRUCTURAL ENGINEERS SPECIFICATION.
CLIENT DETAILS: PROJECT ADDRESS: APPROVED BY: PROJECT NAME:
PROPOSED RESIDENTIAL DUPLEX
INTEGRA PARTNERSHIPS TITLE: STATUS:
22 GRANT STREET STORMWATER LAYOUT FOR APPROVAL - NOT FOR
© ABN 89 647 469 707
02 06/12/22 RFI UPDATE BRP BRP NW
NOOSA HEADS, QLD, 4567 NATHAN WAGSTAFF PLAN CONSTRUCTION
75 NOOSA DRIVE RPEQ: 20693
01 09/11/2022 ISSUED FOR APPROVAL MVP NW NW SCALE:
NOOSA HEADS, QLD 4567 CPEng
+61 7 5211 1003 REV DATE DESCRIPTION DWN CHK APP
1:100 DATE: 06/12/2022
DRAWING NUMBER: PROJECT NUMBER: SHEET REV:
SIZE:
RECORCONSULTING.COM REVISIONS
DO NOT SCALE, IF IN DOUBT ASK
040 20220218 A1 02
Page 19
UP
13
N 73
NOOSA COUNCIL 1
APPROVED PLAN
MCU22/0172, OPW22/0243 &
RAL22/0024
25 JANUARY 2023
GRANT STREET
90
SITE CATCHMENT AREAS
FRACTION
PAVED AREA ROAD AREA ROOF AREA PERVIOUS
NAME AREA (M²) IMPERVIOUS
(M²) (M²) (M²) AREA (M²)
(%)
EXISTING DEVELOPMENT CATCHMENTS EXISTING 105.5 21.5 129.9 337.8 594.7 43.2
PROPOSED 161.7 75.2 197.2 160.6 594.7 73.0
CHANGE 56.2 53.7 67.3 -177.2 0 29.8
LEGEND
PERVIOUS GROUND
IMPERVIOUS GROUND
DRIVEWAY SURFACE
IMPERVIOUS ROOF
21.17
Gully Pit
IL19.82
375dia
Telstra Pit
Hyd
Power pole
PROPOSED DEVELOPMENT CATCHMENTS
CLIENT DETAILS: PROJECT ADDRESS: APPROVED BY: PROJECT NAME:
PROPOSED RESIDENTIAL DUPLEX
INTEGRA PARTNERSHIPS TITLE: STATUS:
22 GRANT STREET STORMWATER CATCHMENT FOR APPROVAL - NOT FOR
© ABN 89 647 469 707
NOOSA HEADS, QLD, 4567 NATHAN WAGSTAFF LAYOUT PLANS CONSTRUCTION
75 NOOSA DRIVE RPEQ: 20693
SCALE:
NOOSA HEADS, QLD 4567 CPEng
+61 7 5211 1003 REV DATE DESCRIPTION DWN CHK APP
1:100 DATE: 06/12/2022
DRAWING NUMBER: PROJECT NUMBER: SHEET REV:
SIZE:
RECORCONSULTING.COM REVISIONS
DO NOT SCALE, IF IN DOUBT ASK
045 20220218 A1 01
Page 20
N NOOSA COUNCIL
APPROVED PLAN
MCU22/0172, OPW22/0243 &
RAL22/0024
25 JANUARY 2023
GRANT STREET
B99
B99 STANDARDS 2004 (AU_NZ)
(c) 2022 Transoft Solutions, Inc. All rights reserved.
STANDARDS 2004 (AU_NZ)
All rights reserved.
(c) 2022 Transoft Solutions, Inc.
Vertical Geometry Grade (%) 12.500 % 2.500 % 5.001 % 1.235 % 0.000 %
Ground Clearance (units: m)
Vertical Grade Length 1.500m 1.500m 1.500m 3.400m 1.200m
Part # Front Wheelbase Rear
Vertical Curve Length (m) #1 0.12 0.12 0.12
Vertical Curve K Value
DATUM R.L. 17.00
DEPTH TO
-0.000
-0.088
-0.015
-0.122
-0.421
-0.652
-0.932
NATURAL SURFACE
DESIGN HEIGHT
21.058
21.245
21.283
21.358
21.377
21.395
21.400
NATURAL SURFACE
21.058
21.157
21.268
21.480
21.798
22.047
22.332
CHAINAGE
1.5
4.5
7.5
0
3
6
9
HORIZONTAL SCALE 1:100
VERTICAL SCALE 1:100
LONGITUDINAL SECTION Driveway
CLIENT DETAILS: PROJECT ADDRESS: APPROVED BY: PROJECT NAME:
PROPOSED RESIDENTIAL DUPLEX
INTEGRA PARTNERSHIPS TITLE: STATUS:
22 GRANT STREET DRIVEWAY LONG SECTION FOR APPROVAL - NOT FOR
© ABN 89 647 469 707
02 06/12/22 RFI UDPATE ML BP NW
NOOSA HEADS, QLD, 4567 NATHAN WAGSTAFF CONSTRUCTION
75 NOOSA DRIVE RPEQ: 20693
01 09/11/2022 ISSUED FOR APPROVAL MVP NW NW SCALE:
NOOSA HEADS, QLD 4567 CPEng
+61 7 5211 1003 REV DATE DESCRIPTION DWN CHK APP
1:100 DATE: 06/12/2022
DRAWING NUMBER: PROJECT NUMBER: SHEET REV:
SIZE:
RECORCONSULTING.COM REVISIONS
DO NOT SCALE, IF IN DOUBT ASK
062 20220218 A1 02
Page 21
2 PHE woo
1 SYZ res 2 ALP cae
2 SYZ res 1 ALP cae 1 SYZ res
4 ALE cor PHE woo 1 PHE woo
SCREENED BIN ENCLOSURE
2 ALP cae
SELECT 1.8 HIGH FENCE BY ARCHITECT
1 ACR imp
PATH
3 BAN CC
1 POA lab
1 ACM hem
3 WES zen 6 CIS ant
STREET
STAINLESS WIRES ABOVE
CE
REMOVE EXISTING CALLISTEMON
Species TO CONNECT FOOTPATH 3 POA lab
ACCESS
2 AUS dul
REMOVE AND RELOCATE SW INLET 2 CIS ant
9 DIA con
OVERHEAD POWER LINES
5 FIC nod
2 LIR mus
NEW CONCRETE CROSSOVER AND
DRIVEWAY TO ENGINEERS DESIGN
1 CAS CI
1 POA lab
STAINLESS WIRES ABOVE
2 TEC hil
6 LIR mus
GRANT
3 LIR mus
2 FIC nod
12 DIA con
2 BLE SL
NOOSA COUNCIL
2 CIS ant
2 AUS dul
APPROVED PLAN
CE
3 POA lab MCU22/0172, OPW22/0243 &
3 BAN CC
RAL22/0024
1 BAN int
1 AUS dul 7 CIS ant 25 JANUARY 2023
1 POA lab
1 WES fru
PATH
PROVIDE NEW
STREET TREE
1 ALE cor
1 XAN chr
22 24 SELECT 1.8 HIGH FENCE BY ARCHITECT
23
2 PHE woo 3 ALP cae
21
1 SYZ res 1 PHE woo 1 PHE woo
2 ACR imp 1 SYZ res 1 ALP cae
2 ALP cae 1 SYZ res
SHEET 02 - PLANTING PLAN - OPERATIONAL WORKS FOR COUNCIL APPROVAL
AMENDMENTS
TREE PLANTING ACCENT PLANTING SELECT FEATURE PROJECT
PROPOSED DUPLEX AT no
rth
element design
issue date description
ROCKS VERGE VEGETATION
A
B
22.09.22 ISSUE FOR COUNCIL APPROVAL
27.09.22 MINOR TREE ADJUSTMENT TO BE REMOVED
22 GRANT STREET
LEGEND
C 04.11.22 AMEND TO INFORMATION REQUEST landscape architecture NOOSA HEADS
D 04.11.22 CLIMBER SPECIES ADDED
SHRUB PLANTING GROUNDCOVER CORTEN STEEL BOUNDARY MASTER PLANNING SUBDIVISIONS
CE COMMERCIAL DEVELOPMENTS RESORTS Date SEPTEMBER 2022
PLANTING EDGE OR SIMILAR
PARKLANDS REVEGETATION MULTI-UNITS
APPROVED
151 Brisbane Rd. Mooloolaba
CLIENT
INTEGRA PARTNERSHIPS Scale 1: 100 @ A3
Phone 07 5444 6155 Fax 07 5444 6055 DWG
Design JS Drawn JS
BLUESTONE
Copyright in the whole and every part of this document belongs to
ELEMENT DESIGN QLD PTY LTD and may not be used, sold,
TURF SELECT FEATURE
GRAVEL STEPPERS OR
PO Box 1546, Buderim QLD 4556
[email protected]
TITLE
PLANTING PLAN - Front Sheet 02 OF 05
transferred, copied or reproduced in whole or in part in any manner or TM issue
form or in or on any media to any person without the prior written
consent of ELEMENT DESIGN QLD PTY LTD.
SIMILAR
ED 22295 OPW - 02 D
Page 22
NOOSA COUNCIL
APPROVED PLAN 1 BLE SL 1 POA lab
1 ACR imp
MCU22/0172, OPW22/0243 & 1 PHE woo
20 OPH jap
3 POA lab 30 OPH jap
4 LIR EG
3 HEL HRN
1 SYZ res
1 SYZ res
RAL22/0024 1 BLE SL 3 ALE cor 1 SYZ res
23 24 25 26 27
25 JANUARY 2023
1 ACR imp
1 ALE cor
1 POA lab
4 LIR EG
1 FIC nod
1 BAN rob
2 AUS dul
2 SYZ res
2 BLE SL
2 CAS CI 2 SYZ res
15 OPH jap
3 AUS dul 6 LIR EG
1 FIC nod
1 HEL HRN
DRYING COURT / SERVICES 1 ALP cae
2 CAS CI
2 ACM hem
2 BLE SL
2 AUS dul
DRYING COURT / SERVICES
2 CAS CI 1 BLE SL 3 ALP cae
3 AUS dul 6 LIR EG
1 HEL HRN
1 BAN rob 1 ALE cor
2 CAS CI
1 FIC nod
3 LIR EG 1 SYZ res
1 SYZ res
25
23 24 1 ACR imp
26 27
1 BLE SL 1 ACR imp 1 SYZ res
2 SYZ res
1 PHE woo 20 OPH jap 3 HEL HRN
30 OPH jap 1 ALP cae 4 LIR EG
1 BLE SL 1 POA lab 2 ALE cor
SHEET 03 - PLANTING PLAN - OPERATIONAL WORKS FOR COUNCIL APPROVAL
AMENDMENTS
TREE PLANTING ACCENT PLANTING SELECT FEATURE PROJECT
PROPOSED DUPLEX AT no
rth
element design
issue date description
ROCKS VERGE VEGETATION
A
B
22.09.22 ISSUE FOR COUNCIL APPROVAL
27.09.22 MINOR TREE ADJUSTMENT TO BE REMOVED
22 GRANT STREET
LEGEND
C 04.11.22 AMEND TO INFORMATION REQUEST landscape architecture NOOSA HEADS
D 04.11.22 CLIMBER SPECIES ADDED
SHRUB PLANTING GROUNDCOVER CORTEN STEEL BOUNDARY MASTER PLANNING SUBDIVISIONS
CE COMMERCIAL DEVELOPMENTS RESORTS Date SEPTEMBER 2022
PLANTING EDGE OR SIMILAR
PARKLANDS REVEGETATION MULTI-UNITS
APPROVED
151 Brisbane Rd. Mooloolaba
CLIENT
INTEGRA PARTNERSHIPS Scale 1: 100 @ A3
Phone 07 5444 6155 Fax 07 5444 6055 DWG
Design JS Drawn JS
BLUESTONE
Copyright in the whole and every part of this document belongs to
ELEMENT DESIGN QLD PTY LTD and may not be used, sold,
TURF SELECT FEATURE
GRAVEL STEPPERS OR
PO Box 1546, Buderim QLD 4556
[email protected]
TITLE
PLANTING PLAN - Rear Sheet 03 OF 05
transferred, copied or reproduced in whole or in part in any manner or TM issue
form or in or on any media to any person without the prior written
consent of ELEMENT DESIGN QLD PTY LTD.
SIMILAR
ED 22295 OPW - 03 D
Page 23
NOOSA COUNCIL
APPROVED PLAN
MCU22/0172, OPW22/0243 &
RAL22/0024
25 JANUARY 2023
c ed
MIN 1500mm
c ed c ed
DIAL BEFORE
YOU DIG
WWW. 1100.com.au
SHEET 04 - DETAILS PLAN - OPERATIONAL WORKS
AMENDMENTS PROJECT
PROPOSED DUPLEX AT
element design
issue date description
A 22.09.22 ISSUE FOR COUNCIL APPROVAL
B 27.09.22 MINOR TREE ADJUSTMENT
22 GRANT STREET
LEGEND
C 04.11.22 AMEND TO INFORMATION REQUEST landscape architecture NOOSA HEADS
D 04.11.22 CLIMBER SPECIES ADDED
MASTER PLANNING SUBDIVISIONS
COMMERCIAL DEVELOPMENTS RESORTS Date SEPTEMBER 2022
PARKLANDS REVEGETATION MULTI-UNITS
151 Brisbane Rd. Mooloolaba
CLIENT
INTEGRA PARTNERSHIPS Scale 1: 150 @ A3
Phone 07 5444 6155 Fax 07 5444 6055 DWG
Design JS Drawn JS
Copyright in the whole and every part of this document belongs to
ELEMENT DESIGN QLD PTY LTD and may not be used, sold,
PO Box 1546, Buderim QLD 4556
[email protected]
TITLE
DETAILS PLAN Sheet 04 OF 05
transferred, copied or reproduced in whole or in part in any manner or TM issue
form or in or on any media to any person without the prior written
consent of ELEMENT DESIGN QLD PTY LTD. ED 22295 OPW - 04 D
The text continues on page 24.
Used in these records
SUPERSEDED - Appproved Plans MCU22-0172 RAL22-0024 OPW22-0243.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file