Council archive · source document
SUPERSEDED - Appproved Plans MCU22-0172 RAL22-0024 OPW22-0243 · MCU22/0172
Plans and drawings: the text below has words only, no drawings.
Very large file (10.0 MB): may take a few minutes to open.
NOOSA COUNCIL LEGEND APPROVED PLAN MCU22/0172, OPW22/0243 & SW SW PROPOSED STORMWATER DRAINAGE RAL22/0024 PROPOSED GRATE 25 JANUARY 2023 PROPOSED FIELD INLET PIT PROPOSED STORMWATER TANK DRAINAGE NOTES 1. REFER HYDRAULIC DRAWINGS FOR BUILDING DRAINAGE DETAILS. BU CP 2. ALL ROADWORKS AND DRAINAGE (EXTERNAL TO SITE BOUNDARIES P1 AND/OR COUNCIL OWNED DRAINAGE PIPES INTERNAL TO THE SITE 37 BOUNDARIES) CONSTRUCTION AND TESTING TO BE IN ACCORDANCE WITH NOOSA SHIRE COUNCIL DEVELOPMENT GUIDELINES, DRAWINGS 3 1 AND SPECIFICATIONS. 3. ALL DRAINAGE CONSTRUCTION (PRIVATELY OWNED DRAINAGE LINES INTERNAL TO THE SITE BOUNDARIES) CONSTRUCTED AND TESTED TO DEMOLISH EXISTING STORMWATER BE IN ACCORDANCE WITH RELEVANT AUSTRALIAN STANDARDS. PIT END REMOVE APPROX 8m OF 4. ALL STORMWATER DRAINAGE PIPES INTERNAL TO SITE SHALL BE: Ø225 REDUNDANT PIPE. REINSTATE KERB TO MATCH EXISTING SW SW SW SW SW SW RRJ RCP OR APPROVED EQUIVALENT. SW 7. ALL STORMWATER PIPES ARE TO BE MANUFACTURED TO RELEVANT SW AUSTRALIAN STANDARDS INCLUDING BUT NOT LIMITED TO AS4058 AND SW SW AS1992. 8. STORMWATER DRAINAGE AND STRUCTURES HAVE BEEN DESIGNED FOR OPERATIONAL LOADS ONLY. CONTRACTOR TO CONSIDER CONSTRUCTION LOADINGS AND ENSURE NO EXCESSIVE LOADS ARE PLACED ON STORMWATER DRAINAGE OR STRUCTURES. SW 0.5 9. CONTRACTOR TO CONFIRM LOCATION AND LEVEL OF EXISTING 0.25 STORMWATER DRAINAGE WHERE CONNECTING ON TO EXISTING. 10. CONTRACTOR TO NOTIFY THE SUPERINTENDENT OF ANY UNSUITABLE FOUNDING MATERIAL WITHIN DRAINAGE TRENCH OR STORMWATER SW STRUCTURES AND AWAIT DIRECTION PRIOR TO LAYING OF PIPES. 11. ALL STORMWATER GRATES/LIDS WITHIN TRAFFICABLE AREAS TO BE CLASS "D" IN ACCORDANCE WITH AS3996. 12. ALL GRATES AND LIDS SHALL SIT FLAT WITH ITS SURROUND AND NOT BE LOOSE OR MOVE UNDER WHEEL LOADS. 5 13. ALL STORMWATER STRUCTURES TO BE CONSTRUCTED IN SW ACCORDANCE WITH PROJECT SPECIFICATION, AND LOCAL AUTHORITY SW GUIDELINES AND SPECIFICATIONS. WHERE STRUCTURES EXCEED BU MAXIMUM DEPTH AS IDENTIFIED WITHIN STANDARD DRAWINGS THE CP SW CONTRACTOR WILL ENSURE AN ADEQUATE STRUCTURAL DESIGN IS P5 1.3 0.5 UNDERTAKEN FOR THE SUBJECT STRUCTURE TO BE CONSTRUCTED 71 SW TO. SW 4 14. CONTRACTOR TO ENSURE ALL MANHOLE STRUCTURES COMPLY WITH THE MAXIMUM DEPTH SPECIFIED IN THE PROJECT SPECIFICATION OR 2 SW LOCAL AUTHORITY FROM FINISHED SURFACE LEVEL TO UNDERSIDE OF SW SW ROOF SLAB. ANY NON CONFORMANCE IS TO BE RECTIFIED AT THE 1 CONTRACTORS EXPENSE. SW 0.4 SW SW SW SW SW SW SW 15. ALL FOOTPATHS TO BE CONSTRUCTED IN ACCORDANCE WITH ARCHITECTURAL/LANDSCAPING DRAWINGS AND RELEVANT AUTHORITY STANDARD DRAWINGS AND SPECIFICATIONS. FOOTPATHS TO BE CONSTRUCTED WITH MAXIMUM 2.5% CROSSFALL. SHOULD CONSTRUCTED FOOTPATHS EXCEED 2.5% CROSSFALL, THE PROVIDE HUMES STORMTRAP OR EQUIVALENT OSD WITH MIN. 6000L STORAGE CONTRACTOR WILL BE REQUIRED TO RECTIFY BY REMOVING AND REPLACING AT THEIR COST. EXISTING Ø375mm SW PIPE OUTLET 16. CONCRETE FOOTPATH TO BE 100mm THICK N32 WITH SL72 MESH IN USIL: 19.76 ACCORDANCE WITH NSC STD DWG RS-065, AS1679 AND AS3600 UNO DSIL: 19.49 LENGTH: 35m 17. THE CONTRACTOR IS TO CONFIRM THE LOCATION AND DEPTH OF ALL GRADE: 0.75% SERVICE CONDUITS IN VERGE PRIOR TO COMMENCING WORKS. THE PROVIDE NEW ON GRADE LIP IN LINE STORMWATER SUPERINTENDANT IS TO BE NOTIFIED OF ANY CONFLICTS WITH WORKS INLET PIT AS PER NSC STD DWG DS-061 TO DS-063. IDENTIFIED IN THESE PLANS IMMEDIATELY. MAKE SMOOTH JOIN TO EXISTING Ø375 SW PIPE 18. ALL TRENCH EXCAVATION AND CONSTRUCTION SHALL COMPLY WITH SL: 21.01 THE REQUIREMENTS OF THE QUEENSLAND WORKPLACE HEALTH AND IL: 19.76 SAFETY ACT 2011. 19. REMOVE ANY REDUNDANT DRAINAGE OUTLETS FROM THE KERB AND CHANNEL INCLUDING ANY ASSOCIATED PIPEWORK ACROSS THE FOOTWAY AND REINSTATE THE KERB AND CHANNEL AND THE FOOTWAY AREA IN ACCORDANCE WITH COUNCIL GUIDELINES. 20.ROADBASE MATERIAL SHOULD BE PLACED IN LAYERS AT LEAST 75 MM THICK BUT NOT EXCEEDING 150 MM IN THICKNESS, AND COMPACTED TO A MINIMUM DENSITY OF 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED IN ACCORDANCE WITH AUSTRALIAN STANDARD AS1289.6.2. 21. CONTRACTOR TO UNDERTAKE ROADWORKS TESTING IN ACCORDANCE WITH NOOSA SHIRE COUNCIL GUIDELINES, DRAWINGS AND SPECIFICATIONS. 22.INTERNAL CONCRETE TO BE 125MM THICK (EXCLUDING FINISHED TREATMENTS) N32 IN ACCORDANCE WITH AS1379 AND AS3600. SL72 MESH MIN 50MM TOP COVER TO AS1304. MIN 100MM BASE COURSE WHERE SUBGRADE CBR <=6. LOCATION AND TYPE OF INTERNAL CONCRETE JOINTS TO CONFORM TO STRUCTURAL ENGINEERS SPECIFICATION. CLIENT DETAILS: PROJECT ADDRESS: APPROVED BY: PROJECT NAME: PROPOSED RESIDENTIAL DUPLEX INTEGRA PARTNERSHIPS TITLE: STATUS: 22 GRANT STREET STORMWATER LAYOUT FOR APPROVAL - NOT FOR © ABN 89 647 469 707 02 06/12/22 RFI UPDATE BRP BRP NW NOOSA HEADS, QLD, 4567 NATHAN WAGSTAFF PLAN CONSTRUCTION 75 NOOSA DRIVE RPEQ: 20693 01 09/11/2022 ISSUED FOR APPROVAL MVP NW NW SCALE: NOOSA HEADS, QLD 4567 CPEng +61 7 5211 1003 REV DATE DESCRIPTION DWN CHK APP 1:100 DATE: 06/12/2022 DRAWING NUMBER: PROJECT NUMBER: SHEET REV: SIZE: RECORCONSULTING.COM REVISIONS DO NOT SCALE, IF IN DOUBT ASK 040 20220218 A1 02
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - Appproved Plans MCU22-0172 RAL22-0024 OPW22-0243.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.