220239 - 44 Williams Road, KIN KIN - SSE - TE222036 - 44 Williams Road, Kin Kin QLD 4571 (1) (1)
Attached to the e-mail MCU22/0168 - Information Response - 44 Williams Road Kin Kin.
GENERAL NOTES
1. THE SYSTEM INSTALLER IS RESPONSIBLE TO ESTABLISH THE SOIL CHARACTERISTICS SECOND DWELLING
LOCATION, LEVELS AND DEPTHS OF ALL EXISTING SERVICES
ON-SITE PRIOR TO COMMENCING ANY WORKS
SOIL 0 - 2000 SILTY CLAY (CL)
2. LOCATIONS AND SETOUT DIMENSIONS SHOWN ARE APPROXIMATE
ONLY AND ARE TO BE CONFIRMED ON SITE.
REVISIONS
DISTRIBUTION BOX STRAIGHT # DATE SUBJECT AUTHORISED
3. ACCESS AND LAY DOWN AREAS ARE TO BE CONFIRMED BY THE STRUCTURE MODERATE / STRONG LOW VENT
SYSTEM INSTALLER RAISED CONNECTOR
OFFSET ADAPTER A 14/06/2022 REVISION A C. TAYLOR
4. EXISTING BUILDINGS AND EXTERNAL STRUCTURES SHOWN ON THESE SOIL CATEGORY 4/5
DRAWINGS ARE OBTAINED FROM THE AVAILABLE INFORMATION AND
MAY NOT BE COMPLETE AND ACCURATE PERMEABILITY 0.06 - 0.12 m/DAY
5. ALL DIMENSIONS ARE IN MM U.N.O
900
6. NO TREES TO REMAIN WITHIN 2.0m OF AES FOOTPRINT DESIGN LOADING RATE 10 mm/DAY
7. PLUMBING AND DRAINAGE TO QLD PLUMBING & WASTEWATER ACT,
AS / NZS 3500 DESIGN VOLUME
8. ALL PIPE WORK TO AS / NZS 4020
INSPECTION POINT
2610
9. ALL TANKS TO BE INSTALLED AND ANCHORED IN COMPLIANCE WITH WATER SUPPLY RAIN WATER
THE MANUFACTURERS SPECIFICATIONS
10. FLEXIBLE JOINTS ON ALL INSTALLED TANKS (AS / NZS 3500) VOLUME ALLOWANCE 120 L/P/DAY
1710
11. THERE SHALL BE NO CROSS CONNECTION BETWEEN ANY
WASTEWATER / EFFLUENT PIPEWORK AND ANY POTABLE WATER NUMBER OF BEDROOMS 2
SUPPLY PIPEWORK
12. MINIMUM DISTANCE BETWEEN TANKS AND BUILDINGS TO BE
TAYLOR ENVIRONMENTAL
DESIGN POPULATION 3
MAINTAINED (AS/NZS 3500)
13. USE ONLY A LICENSED DRAINER THAT HAS BEEN ACCREDITED BY TOTAL DESIGN VOLUME 360 L/DAY
THE AES SYSTEM SUPPLIER. THE SUPPLIER WILL NOT PROVIDE THE
AES PIPES UNLESS THE LICENSED DRAINER HAS BEEN TRAINED AND INSPECTION POINT
DISPOSAL AREA
ACCREDITED
14. AES PIPES MUST BE INSTALLED AS PER AES INSTALLATION ∅100 uPVC DWV
2000
DISPOSAL AREA REQUIRED A = Q/DLR = 36.0 m²
INSTRUCTIONS.
15. FINAL LOCATION OF AES BEDS AND ASSOCIATED PIPE WORK CAN INSTALL AS 2x [6.6 x 2.61] = 36 m²
ONLY BE ALTERED ON SITE TO MEET THE SITE CONDITIONS AFTER
APPROVAL FROM TAYLOR ENVIRONMENTAL (AUSTRALIA) PTY LTD TYPE OF FACILITY ADVANCED ENVIRO SEPTIC
16. GRADE ALL BATTERS EVENLY AT 1 IN 5, UNLESS NOTED
OTHERWISE TREATMENT PLANT APPROVAL 15 / 2019
17. ANY SOILS ENCOUNTERED WHICH SHOW EVIDENCE OF
CONTAMINATION ARE TO BE STOCKPILED SEPARATELY.
900
TREATMENT LEVEL ADVANCED SECONDARY
CONTAMINATED SOIL SHALL BE HANDLED IN ACCORDANCE WITH ALL
WORKPLACE HEALTH & SAFETY AND ENVIRONMENTAL REGULATIONS AES CALCULATOR OUTCOMES
18. IT IS THE INSTALLERS RESPONSIBILITY TO PROVIDE ACCURATE 'AS
CONSTRUCTED' DRAWINGS TO RELEVANT LOCAL AUTHORITY AND
NUMBER OF AES PIPE ROWS 2
2610
INCUR ASSOCIATED COST
19. ALL DISTURBED AREAS TO BE RE-GRASSED AND RECTIFIED
NUMBER OF AES PIPES/ROW 2.0
1710
20. EXISTING TOPSOIL IS TO BE RETAINED AND SET ASIDE
(WINDROWED) TO PREVENT DAMAGE FROM MACHINERY AND
BUFFER CAPACITY 890 L
REDISTRIBUTED ONCE INSTALLATION IS COMPLETE
21. AT LEAST A 5 TONNE MACHINE WITH POSI-TRACK SYSTEM IS
BILL OF QUANTITIES
QBCC LICENCE NUMBER 150 556 72
REQUIRED FOR EARTHWORKS TO ELIMINATE POTENTIAL TRACK ABN NUMBER 95268308955
INDENTATIONS INTO GROUND LEVEL
22. IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENGAGE THE
AES PIPES 4
DESIGNER TO UNDERTAKE INSPECTIONS DURING INSTALLATION. 300 3000 300 3000 300 Phone: +61 400 301 364
FAILURE TO DO SO WILL RESULT IN THE FORM 8 / COMMISSIONING COUPLINGS [AESC] 0 Email: [email protected]
CERTIFICATE NOT BEING ABLE TO BE COMPLETED Web: www.taylorenviro.com.au
OFFSET ADAPTOR [AESO] 8 6900
INSTALLATION
- IT IS THE INSTALLERS RESPONSIBILITY TO ENSURE THAT ALL OXYGEN DEMAND VENT [AESODV] 2
COMPONENTS COMPLY WITH THESE GUIDES UPON COMMISSIONING OF
THIS SYSTEM INSPECTION POINT BASE [AESIPB] 4 AES BED PLAN VIEW
- ALL BURIED PIPE WORK IS TO BE IDENTIFIED WITH UNDERGROUND
MARKING TAPE PLACED ABOVE THE PIPE WORK CLEAN COURSE SAND 16 m² WASTE WATER TREATMENT &
- ALONG THE BOUNDARY OF THE LAND APPLICATION AREA THERE
AES FOOTPRINT
EFFLUENT DISPOSAL SYSTEM
SHALL BE AT LEAST 2 WARNING SIGNS CLEARLY VISIBLE TO
ADVISE THAT RECYCLED WATER IS USED (EACH SIGN SHALL
COMPLY WITH AS1319 AND HAVE THE WORDING RECYCLED WATER - LENGTH WIDTH AREA
AVOID CONTACT DO NOT DRINK) AUTHORISED FOR ISSUE DATE
AES SYSTEM 13.8 m 0.9 m 12.4 m² STORMWATER DIVERSION
MAINTENANCE 14/06/2022
- SEPTIC TANKS TO BE CHECKED FOR SOLIDS BUILD UP ANNUALLY EXTENSION AREA 13.8 m 1.71 m 23.6 m² GRASS
- SEPTIC TANKS TO PUMPED OUT IF 31 FULL OF SOLIDS OR 5 YEARS INSPECTION POINT LOW VENT
150 MIN
TOTAL 13.8 m 2.61 m 36.0 m²
(WHICHEVER IS SOONER) STREET ADDRESS
- LAND APPLICATION IS IMPORTANT AND IS TO BE REGULARLY INSPECTION POINT
150 MIN
MOWED AND ANIMALS AND VEHICLES EXCLUDED 44 WILLIAMS RD, KIN KIN 4571
16% SLO
PE
APPROVED SAND
1020 APPROX
LOT & PLAN
150
3 SP127443
150 MIN
300 300 BACK FILL
750
COUNCIL
150 MIN
300
NOOSA SHIRE
1020 APPROX
∅100 LOW VENT WITH
150
150
MOSQUITO PROOF MESH NAME OF CLIENT
900 1710 300 300
COTTERILL
750
TURF ALL FINAL GRADES. NO DEEP ROOTED
ROTATE
PLANTS ON SYSTEM OR OVERFILL AREAS
2610 DESIGNER
300
150
150
ROTATE UNTIL LEVEL WITH TOP C. TAYLOR
OF OFFSET ADAPTER
TOP VIEW 100 RIP & SCARIFY 300mm DRAWN
900 1710
50-100MM 2221 ° ELBOW 100MM ∅ S&D PIPE APPLY GYPSUM 1kg/m²
LEVEL
GEOTEXTILE FIBER WRAP
2000 2610 M. MAHONY
LEVEL
RANDOMLY ORIENTATED DRAWING DETAILS
FIBER MAT
SLOPE
SECOND DWELLING DETAIL
AES PIPE
ADVANCED E-S PIPE SIDE VIEW OFFSET ADAPTERS
OFFSET ADAPTOR JOB NUMBER
ORIGINAL SOIL AES BED SECTION VIEW TE222036
APPROVED SAND
SCALE REVISION DWG #
STRAIGHT RAISED CONNECTION LOW VENT N/A A SL4