24. The full length of the Peregian Esplanade frontage of the development site shall be
upgraded by providing kerb & channel. The kerb and channel shall be extended to the
existing Council catchpit located approximately 7 metres to the north of the site. The
alignment of the kerb and channel and any required modifications or improvements to
the existing catch pit shall be at the direction of Council at the time of engineering design.
All associated and ancillary work including pavement correction to the existing
pavement, drainage works, modification of the footpath, and adjustments to the existing
infrastructure shall be undertaken as part of these works.
In this regard, plans detailing this work shall be prepared and submitted to Council for
approval prior to obtaining a Development Permit for Operational Works.
25. All paths, driveways and parking areas must be designed and constructed to ensure
pedestrian safety using non-slip materials, to produce an evenly graded surface finish,
and to be in accordance with the Disability Discrimination Act 1992 and Australian
Standard 1428.1 Design for Access & Mobility.
26. All redundant vehicular crossings to the site must be removed and replaced by kerb &
channel, footpath paving and landscaping such as trees and grasses in accordance with
Council’s Standard specifications prior to commencement of the use permitted by this
permit.
Roof Water & Stormwater Drainage
27. Roof runoff from any dwelling must be directed to a rainwater storage system or tank
that is installed to ensure water from the rainwater storage system or tank is used for
external uses (such as watering gardens, irrigation, ornamental ponds, water features,
topping-up swimming pools, outdoor cleaning, etc) and for internal (ground floor) use in
washing machine cold taps and toilet cisterns. All rainwater tanks are to be designed
and installed in accordance with the Queensland Development Code (QDC) current at
the time of building approval, and must be part of the plumbing application for approval.
The location and capacity of the tanks must be clearly shown on the plans submitted for
Building Works and Operational Works approval and any overflow must be directed to
the stormwater drainage system.
28. All stormwater drainage (including roof water overflow from the rainwater storage
system) must be collected and discharged so there is no net increase in stormwater
runoff from the site. Stormwater drainage permitted to drain from the site must be
discharged to Council’s existing drainage structures in Peregian Esplanade. Plans of
the drainage design must be prepared by a Registered Professional Civil Engineer and
submitted to Council prior to obtaining a Development Permit for Operational Works.
29. Stormwater runoff from the proposed carparking areas and driveway must be directed
to the stormwater drainage system.
30. All site stormwater drainage must be by means of a gravity system.
Earthworks
31. Filling works required on site must be carried out in accordance with Council’s Planning
Scheme Policy PSP5 – Engineering Design Standards, so as not to cause the additional
ponding of water on any adjoining lands or the blockage of, or interference with, any
natural watercourses.
32. Earthworks carried out on site must not affect the structural integrity of any of the existing
fences or structures that border the development site. Fences that are affected must be
replaced prior to the Building Certifier issuing the Certificate of Classification. In this
regard any fences to be replaced must be clearly shown on the plans submitted for
Operational Works approval.
Site Stability
Page 6 of 13
Document Set ID: 24928702
Version: 6, Version Date: 09/07/2026
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Other Change Decision Notice - MCU10 2113 03 (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 184 KB (small file)
- File type
No other editions are linked here.