Original source · versioned page text
Appendix C - Stormwater Management Plan
Attached to the e-mail MCU15/0095 & REC15/0022 Development Application Stormwater Mgmt Plan (2 of 3).
Original PDF page 38, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnSolution for Non-Compliant Petrol Stations SPEL Puraceptor Class 1 stormwater treatment system is a solution for the “satment, capture and retention of focarbons off petrol stations. SPEL Puraceptor Class 1 can rationalize the existing use of service stations in conformity with the applicable environmental guidelines and put in place ongoing operational measures to prevent the likelihood of contamination in the case of an unforeseen future event. SPEL’s Puraceptor Class 1 oil/water separator is connected to the stormwater [provides the site with the hignest degree of environmental protection; - a protection that complies with the councils, and the EPA‘s guidelines.] Puraceptor Benefits © Full retention Class 1 treatment oil/water separator. It treats all liquid. There is no bypass. * Complies with federal and state government regulating environmental guidelines for water quality. ¢ University tested and certified to independent uropean Standard EN BS 858.1 for the capture and ois: of hydrocarbons with a discharge quality of no visible trace from a tested inflow concentrator of 5,000ppm. © Capture and contain oil/fuel spillages. © Can be sized to capture and contain a spill from a refuelling tanker and prevent discharge to stormwater. * Passive gravity function ensuring treatment is continuous. * Equipped with an intrinsically safe oil alert probe providing regular detection for oil build-up. Set to alarm when oil hydrocarbons attain 10% of the chambers volume, * Oil alert probe enables ‘self-monitoring’, suitable for unmanned and remote locations. © Equipped with a flame trap ensuring fire water is extinguished. © Equipped with a vapour trap preventing vapours from discharging and preventing the emission of odours. ¢ Water tight structure © Minimum 50 years life-span. © Low frequency and low cost maintenance iperations & Maintenance manual with a ledger for accurate recording of maintenance operations. ¢ Maintenance performed from ground level; no entering of tank is required, satisfying O.H.& S. requirements. = sap gigi ils Petrol forecourt and surrounds at a busy metropolitan petrol station rendered compliant. The catchment consists of a grated drain encompassing the complete perimeter of the under-sized canopy. Surface water and forecourt runoff drains to the Puraceptor located under the two trafficable covers in the foreground. Puracepter Certification Australian Independent Tests The Puraceptor has been independently tested at Australia's pre- eminent hydraulics research facility, the University of South Australia (UNISA), and at the Uk's leading hydraulics research faculty HR Wallingford. * NAIA analysis of the tests shows a water quality of no visible trace of hydrocarbons from an inflow concentration of 5,000ppm. In-Situ Testing NATA analysis of Puraceptors operating at similar applications in Australia reveal ‘no cletection’ of hydrocarbons from a captured concentration of 8,000ppm. Council Approvais The increasing awareness by councils of the superior European Standard has prompted many to review their current procedures and in only the past eighteen months over sixty councils have approved SPEL for service stations and similar applications with units’ already operational in excess of forty sites, tly tested for *rocucing we ave seen ane (Ts) ’ ya a g ; > swan gross polluraw 11008 Fer) ds (TPH) less, (cenified disenarge quality of ee European standard BSEN e584 y 45h total plrosphovous TS SS \ v >A5ih tocol mitrogen r= aa sf & \ 5 >go%p heavy metals
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.