Council archive · source document
Response to Info Request - Attachment 4a - Engineering Report Part 1 MCU18-0015 & RAL18-0001 · MCU18/0015
Very large file (16.9 MB): the original may take a few minutes to open or download. The page text below is quick to read.
LEGEND:
= —O=—s— — = EXISTING UNITYWATER SEWER
——@— s ——_ PROPOSED UNITYWATER SEWER
—@-—s ———._ PROPOSED BODY CORPORATE SEWER
—@-— s —— _ PROPOSED PRIVATE RISING MAIN
-_——wWw— — = EXISTING UNITYWATER WATER
——W——— PROPOSED UNITYWATER WATER
w PROPOSED BODY CORPORATE WATER
NOTE: NEW SEWER EXTENSION TO BE CONSTRUCTED
USING HORIZONTAL DIRECTIONAL DRILLING. REFER TO
ENGINEERING REPORT BY WALSH ENGINEERS FOR
DETAILS AND TECHNICAL ADVICE
EXISTING SEWER MANHOLE
SM2670588
SL: 22.68
ee a)
eed
=C
———
PROVIDE PRIVATELY OWNED PACKAGE
——__PUMP STATION WITH RISING MAIN TO.
EXISTING MANHOLE SM2670588.
PROVIDE WATER
CONNECTION TO
SERVICE LOT 3.
\y \~ PROPOSED
LOT 3
\) 927m?
\
EXISTING SEWER MANHOLE 2
$M2670601 sf
\ OPEN SPACE
VN PP
eebvcaren
PROVIDE SEWER CONNECTION
TO SERVICE APARTMENTS 1-12. PROVIDE WATER CONNECTION
TO SERVICE PROPOSED
RESIDENTIAL ALLOTMENT.
@ PROPOSED a OE A PROVIDE GROUP TITLE WATER METER
LoT1 : TO SERVICE APARTMENTS 1-12.
EXTENSION FROM EXISTING MANHOLE
$M2668739. EXISTING SL 20.66, IL 19.35.
EXISTING SEWER MANHOLE
SM2668739
SL: 20.65
IL: 19.35
SCALE 1:500 A1, 1:1000 A3
REV DATE DESCRIPTION BY CHKD PROJECT: DRAWING TITLE:
> ov saaa.aaeg Flee ree a Sn nox wanes & |e PROPOSED DEVELOPMENT PRELIMINARY SEWER WALSH
E [email protected] c¢ [sunons =D - we our at 27 ATTUNGA HEIGHTS, NOOSA HEADS AND WATER LAYOUT CONS UELING
W walsheng.net.au for DAVID NEATE
CONSULTING J 4 15/72 Wises Road, Maroochydore Q 4558 are 4665
PO Box 5512, Maroochydore BC Q 4558 ©This plan is Copyright. Other than for the ourposes of and subject to the conditions prescribed under the Copyright Act, no 2
ENGINEERS ABN. 39611 482716 FOR APPROVAL Coe seen cs sarc casonomenaa, naeaecowecone wectestsenccie [_ORWING No: C5756/15/P23 REVISION:
NOT FOR CONSTRUCTION reproduced, stored in a retrieval system or transmitted without the prior written permission of Walsh Consulting Engineers. All
FLEMANE “GHGS ePoSang ONE, DITTO Oo Al Sheet Size | Design:Als | DrawnsAls | Dateroct 2015 J _itlectul oer ema itn wal Censuting engines, llenques shou be dees to Wash Const Erginees COUNCIL REFERENCE: SHEET: 3 of 13
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Response to Info Request - Attachment 4a - Engineering Report Part 1 MCU18-0015 & RAL18-0001.pdfRelated documentApplication case desk ↗
About this file
- File size
- 16.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.