Council archive · source document
RFI - Attachment F - Revised Architectural Plans · MCU25/0053
Plans and drawings: the text below has words only, no drawings.
Original PDF page 7, section 1. The text section number identifies this passage in the reader.
GENERAL NOTES
VERIFY ALL DIMENSIONS AND LEVELS BEFORE COMMENCING WORK. DO NOT SCALE FROM DRAWING.
COPYRIGHT
THE COPYRIGHT OF THESE DOCUMENTS AND ALL WORKS EXECUTED FROM THESE DOCUMENTS
SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR ON CREATION VEST IN THE ARCHITECT.
THESE DOCUMENTS MAY ONLY BE USED TO PRODUCE THE PROJECT FOR THE CLIENT AND IN THE
LOCATION DESCRIBE HEREON
8 MCU RFI RESPONSE 22.09.25
7 CONSULTANT ISSUE 02.05.25
6 CONSULTANT ISSUE 30.04.25
5 STRUCT UPDATES 09.04.25
4 UPDATED BASEMENT, STRUCTURE 11.03.25
3 GENERAL UPDATES 30.01.25
2 CONSULTANT COORDINATION 16.01.25
1 2 2 1
40.02 REV DESCRIPTION DATE
40.03 40.03 40.02
1 2 3 4 5 6 7 REVISION SCHEDULE
LEGEND
CODE DESCRIPTION
AFG-SD1 ALUMINIUM FRAMED GLAZED SLIDING DOOR - 4-PANEL XXXO
AFG-SD2 ALUMINIUM FRAMED GLAZED SLIDING DOOR - 3-PANEL XXO
AFG-SD3 ALUMINIUM FRAMED GLAZED SLIDING DOOR - 2-PANEL XO
BAL-01 BALUSTRADE TYPE 1
BLK-200 190mm CORE-FILLED BLOCKWORK
7292 3380 8500 7160 11435 6000 4690 7000 CNC-PF CONCRETE - PAINT FINISH
COL-A CONCRE COLUMN - PAINT FINISH
COL-B STEEL COLUMN
VB VANITY BASIN
WC TOILET SUITE
190
300 1005 95 4305 95 200
2005
150 1700 95 2275 95 1150 350 2685
150 5840 200
150 5315 150 2885
A A
150 650 0 750 150360
200 790 390
DOOR LEGEND
COL-A COL-A LEVEL OR UNIT NUMBER
***
DOOR NUMBER D**
AFG-SD2 AFG-SD2
WINDOW/GLAZING LEGEND
BED 1
3575
W** L**
CPT-01 COL-A COL-A
WINDOW NUMBER LEVEL NUMBER
MASTER SUITE
4000
CPT-01
2 WALL TYPES
WT-20
40.01
95
PARTITION STUD WALL WITH LININGS AS NOTED,
11210
WT-12
AFG-SD1 REFER ARCH. SCHEDULES
VB
WIR ENS 1 WT-20 CONCRETE/PRECAST WALL/PANEL. FINISHES AS
2205
SHR
95
FT-01 NOTED, REFER ARCH. SCHEDULE
BLK-200
WC CONCRETE/PRECAST WALLPANEL WITH LINING.
BLK-200
WIR
2210
FINISHES AS NOTED, REFER TO ARCH. SCHEDULE
65
BALCONY WT-20 CPT-01
CONCRETE BLOCK WALL WITH LINING.
VOID
EX-FT-01
CNC-PF WT-20 BALCONY FINISHES AS NOTED, REFER ARCH. SCHEDULE
FFL 6.350 EX-FT-01
95
CONCRETE BLOCK WALL. FINISHES AS NOTED, REFER
AFG-SD2
WT-20
BLK-200 FFL 6.360
ARCH. SCHEDULE
BED 2 COL-B
1780
VOID
4210
BAL-01 ALUMINIUM FRAMED GLAZING SUITE. REFER TO
FT-01 WC
WT-20
ELEVATIONS AND DETAILS.
ENS 2 COL-B COL-B
95
FT-01 SHR HALL WT-20 BLK-200 SERVICE PENETRATION ZONE
VB COL-B TMF-01
B WIR B
2190
AFG-SD3
CPT-01
80
WT-20
BLK-200 LIFT WT-20 BLK-200 COL-A
GENERAL NOTES:
AFG-SD2
1005 95
BAR SK HT HOSE TAP 1. REFER TO ARCHITECTURAL & INTERIOR FINISHES SCHEDULES FOR
BED 3 WC WC SYSTEMS, LININGS & FINISHES.
4400
VOID VOID VOID VOID 2. ALL WET AREAS TO HAVE WET AREA PLASTERBOARD OR EQUAL.
3720
1 CPT-01 WT-20
3. FALLS TO SCREED TO BE PROVIDED TO WET AREAS TO COMPLY WITH
40.01 ENS 3 ENS BATH AS1428.1 GRADES FOR BATHROOM AND SHOWER FLOORS.
WT-20
FT-01 WC SHR SHR FT-01
1705
UPPERMOST FFL NOTED ONLY.
VB VB
VB VB 4. ALL WALLS AND PARTITIONS TO ALLOW FOR STRUCTURAL
HT DEFLECTION AND STRUCTURAL MOVEMENT.
600
C C 5. REFER TO NCC REPORT & ACOUSTIC REPORT FOR ACOUSTIC
280
1000 280
BLK-200 BLK-200 BLK-200 REQUIREMENTS. ACOUSTIC LINING TO ALL TIMBER FLOORS.
BLK-200 BLK-200
6. REFER TO NCC REPORT & ESD REPORT FOR THERMAL
REQUIREMENTS.
2500
7. FIRE HYDRANT AND FIRE HOSE REEL INSTALLATIONS TO COMPLY
2300
WITH AS2419 AND AS2441.
1500
8. VERIFY ALL DIMENSIONS/SETOUTS ON SITE PRIOR TO
CONSTRUCTION.
9. REFER TO CONSULTANT DRAWINGS FOR SERVICES LOCATIONS AND
SIZES. CONTRACTOR TO VERIFY PRIOR TO CONSTRUCTION.
150 4020 60095 1010 95 2430 100 2100 200 5660 200 3955 1175 675 1200 250280 1100 1800 110 1005 95 1464 95 1464 95 1521 150 3390 200600190 310 10. REFER TO ELEVATIONS FOR FURTHER FINISHES AND PANEL SETOUT
110 1005 95 4305 200150 INFORMATION.
11. ALL STRUCTURAL STEEL TO BE HOT DIPPED GALVANISED, REFER
135 STRUCTURAL ENGINEERS DETAILS
12. OVERFLOW LOCATIONS TO BE COORDINATED WITH HYDRAULIC
ENGINEER, OVERFLOW REQUIRED BY THE HYDRAULIC ENGINEER TO
BE COORDINATED WITH THE ARCHITECT.
13. REFER TO ELEVATIONS FOR FACADE SCREEN SET-OUT.
14. ALL EXPOSED CONCRETE WALLS/COLUMNS TO BE CLASS 2 FINISH.
ANY BACK OF HOUSE CONCRETE WALLS/COLUMNS TO BE CLASS 3
FINISH.
15. DISCONTINUOUS CONSTRUCTION AS REQUIRED TO COMPLY WITH NCC
REQUIREMENTS.
16. ROOF VENTILATION REQUIRMENTS BY OTHERS. CONTRACTOR TO
VERIFY PRIOR TO CONSTRUCTION.
1 2 3 4 5 6 7
bureau^proberts PTY LTD
ABN 53 073 087 993 ACN 073 087 993
LEVEL 14, 100 CREEK STREET, BRISBANE QLD 4000, GPO Box 3204 QLD 4001
P: 07 3221 0672 F: 07 3221 0683 EMAIL : [email protected] www.bureauproberts.com.au
CLIENT:
SEYMOUR GROUP
PROJECT:
NOOSA RESIDENCE
ADDRESS:
7 NOOSA PARADE
DRAWN BY: NORTH:
TH
CHECK BY:
JC
PROJECT
ARCHITECT JC
DESIGN
ARCHITECT AB
SCALE:
10 1 : 100 [A1]
DRAWING TITLE:
G.A. FIRST FLOOR PLAN
CAD FILE REF: DATE:
C:\_Revit Local\24048_7 Noosa Parade_B.A_larissaf4R2ZR.rvt
22.09.25
PROJECT NO: PHASE: DRAWING NUMBER: REVISION:
24048 B.A. AR 21.03 8
22/09/2025 3:37:00 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - Attachment F - Revised Architectural Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.