Council archive · source document
RFI - Attachment F - Revised Architectural Plans · MCU25/0053
Plans and drawings: the text below has words only, no drawings.
Original PDF page 11, section 1. The text section number identifies this passage in the reader.
GENERAL NOTES
VERIFY ALL DIMENSIONS AND LEVELS BEFORE COMMENCING WORK. DO NOT SCALE FROM DRAWING.
COPYRIGHT
THE COPYRIGHT OF THESE DOCUMENTS AND ALL WORKS EXECUTED FROM THESE DOCUMENTS
SHALL REMAIN THE PROPERTY OF THE ARCHITECT OR ON CREATION VEST IN THE ARCHITECT.
THESE DOCUMENTS MAY ONLY BE USED TO PRODUCE THE PROJECT FOR THE CLIENT AND IN THE
LOCATION DESCRIBE HEREON
9 MCU RFI RESPONSE 22.09.25
8 CONSULTANT ISSUE 02.05.25
7 CONSULTANT ISSUE 30.04.25
6 MINOR UPDATES 24.04.25
5 BOAT STORE REMOVAL 16.04.25
4 UPDATED BASEMENT, STRUCTURE 11.03.25
3 GENERAL UPDATES 30.01.25
REV DESCRIPTION DATE
REVISION SCHEDULE
LEGEND
1 2 3 4 5 6 7 CODE DESCRIPTION
AFG-01 ALUMINIUM FRAMED GLAZING - TYPE 1
BAL-01 BALUSTRADE TYPE 1
3380 8500 7160 17435 4690 CNC-PF CONCRETE - PAINT FINISH
SCN-01 SCREEN - TYPE 1
SST STACKED STONE VENEER
CNC-PF 8M HEIGHT
ROOF
RL 9.800
SITE BOUNDARY
3450
SCN-01
BALCONY BED 3 ENS 3 ENS BALCONY BAL-01
01_FIRST FLOOR
RL 6.350
3650
3200
BED 4 BED 5 SIDE COURT OUTDOOR ROOM FAMILY STAIR PDR SCULLERY
REAR TERRACE
00_GROUND FLOOR RL 2.100 DRIVEWAY
DFL
RL 2.700 14
RL 2.400 7
3400
4 NATURAL GROUND LINE
GARAGE CELLAR
8
-01_BASEMENT
RL -0.700
SECTION 01
1 1 : 100
GENERAL NOTES:
1. REFER TO ARCHITECTURAL & INTERIOR FINISHES SCHEDULES FOR
SYSTEMS, LININGS & FINISHES.
2. ALL WET AREAS TO HAVE WET AREA PLASTERBOARD OR EQUAL.
3. FALLS TO SCREED TO BE PROVIDED TO WET AREAS TO COMPLY WITH
AS1428.1 GRADES FOR BATHROOM AND SHOWER FLOORS.
UPPERMOST FFL NOTED ONLY.
4. ALL WALLS AND PARTITIONS TO ALLOW FOR STRUCTURAL
DEFLECTION AND STRUCTURAL MOVEMENT.
5. REFER TO NCC REPORT & ACOUSTIC REPORT FOR ACOUSTIC
REQUIREMENTS. ACOUSTIC LINING TO ALL TIMBER FLOORS.
1 2 3 4 5 6 7 6. REFER TO NCC REPORT & ESD REPORT FOR THERMAL
REQUIREMENTS.
7. FIRE HYDRANT AND FIRE HOSE REEL INSTALLATIONS TO COMPLY
WITH AS2419 AND AS2441.
8. VERIFY ALL DIMENSIONS/SETOUTS ON SITE PRIOR TO
CONSTRUCTION.
9. REFER TO CONSULTANT DRAWINGS FOR SERVICES LOCATIONS AND
SIZES. CONTRACTOR TO VERIFY PRIOR TO CONSTRUCTION.
3380 8500 7160 17435 4690 10. REFER TO ELEVATIONS FOR FURTHER FINISHES AND PANEL SETOUT
INFORMATION.
SITE BOUNDARY
SITE BOUNDARY
11. ALL STRUCTURAL STEEL TO BE HOT DIPPED GALVANISED, REFER
STRUCTURAL ENGINEERS DETAILS
12. OVERFLOW LOCATIONS TO BE COORDINATED WITH HYDRAULIC
ENGINEER, OVERFLOW REQUIRED BY THE HYDRAULIC ENGINEER TO
BE COORDINATED WITH THE ARCHITECT.
CNC-PF 8M HEIGHT 13. REFER TO ELEVATIONS FOR FACADE SCREEN SET-OUT.
14. ALL EXPOSED CONCRETE WALLS/COLUMNS TO BE CLASS 2 FINISH.
ANY BACK OF HOUSE CONCRETE WALLS/COLUMNS TO BE CLASS 3
ROOF
FINISH.
RL 9.800
15. DISCONTINUOUS CONSTRUCTION AS REQUIRED TO COMPLY WITH NCC
REQUIREMENTS.
AFG-01 AFG-01 16. ROOF VENTILATION REQUIRMENTS BY OTHERS. CONTRACTOR TO
SCN-01 VERIFY PRIOR TO CONSTRUCTION.
3450
BALCONY BED 1 MASTER SUITE BALCONY
3100
3100
BAL-01
01_FIRST FLOOR SST
RL 6.350
CNC-PF
CNC-PF
3650
3220
FRONT COURT POOL TERRACE LIVING REAR TERRACE
bureau^proberts PTY LTD
ABN 53 073 087 993 ACN 073 087 993
LEVEL 14, 100 CREEK STREET, BRISBANE QLD 4000, GPO Box 3204 QLD 4001
P: 07 3221 0672 F: 07 3221 0683 EMAIL : [email protected] www.bureauproberts.com.au
CLIENT:
00_GROUND FLOOR
RL 2.700 DFL SEYMOUR GROUP
RL 2.400 PROJECT:
CNC-PF NOOSA RESIDENCE
NATURAL GROUND LINE ADDRESS:
3400
PLANT GARAGE SPA 7 NOOSA PARADE
CNC-PF
-01_BASEMENT
RL -0.700 DRAWN BY: NORTH:
TH
CHECK BY:
JC
PROJECT
ARCHITECT JC
DESIGN
SECTION 02 ARCHITECT AB
2 1 : 100 5 1 : 100 [A1]
SCALE:
DRAWING TITLE:
SECTIONS 1 & 2
CAD FILE REF: DATE:
C:\_Revit Local\24048_7 Noosa Parade_B.A_larissaf4R2ZR.rvt
22.09.25
PROJECT NO: PHASE: DRAWING NUMBER: REVISION:
24048 B.A. AR 40.01 9
22/09/2025 3:37:14 PM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - Attachment F - Revised Architectural Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.