GENERAL NOTES
• ALL FIRST FLOOR WINDOWS TO BE
RESTRICTED TO A MAXIMUM 125MM
OPENING
• DOORS TO WC, POWDER ROOM WC, &
ENSUITE WC TO BE FITTED WITH LIFT
DOWNPIPE DROPPER
450 450 OFF HINGES IN ACCORDANCE WITH
B.C.A. 3.8.3
• WINDOW HEAD HEIGHT DIMESIONS TO
5.00° 5.00° BE TAKEN TO THE NEAREST BRICK
DOWNPIPE DROPPER
COURSE (UNLESS NOTED OTHERWISE)
• ALL GLAZING TO COMPLY WITH A.S.
1288-2006 (Amdt 1-2008) (REFER TO
FEATURE FIBRO/COMPOSITE ENERGY RATING FOR ALL GLAZING
1600
CLADDING TO BALCONY
VALUES.)
• FOAM SYSTEM REFER TO ATTACHED
2700
400MM AXON CLADDING
(OR SIMILAR) FIXED TO
SPECIFICATIONS (WHERE APPLICABLE)
STUDWORK
1100
FIRST FLOOR
400 60
325
2800
2400
GROUND FLOOR
60
PROPOSED FILL
NATURAL GROUND LEVEL
STONEWORK FIXED TO
ELEVATION C EASYLAP CLADDING EPS/HEBEL CLADDING TO
ALFRESCO
Scale 1 : 100
COLORBOND ROOF
SHEETING, FASCIA, AND
RAISED ROOF
GUTTER
500
425
2700
400MM AXON CLADDING
(OR SIMILAR) FIXED TO
STUDWORK
FIRST FLOOR
325
2800
405MM STRIA CLADDING
(OR SIMILAR) FIXED TO
HWS STUDWORK
AC
GROUND FLOOR
180
GARAGE
PROPOSED FILL
NATURAL GROUND LEVEL
ELEVATION D
Scale 1 : 100
HOUSE TYPE A
Rev Date Amendment Init Stage: Drawing Title:
"THIS WORK IS OWNED BY CDS DESIGN CONSULTANTS
PTY LTD, AND CANNOT BE REPRODUCED OR COPIED,
A
B
05/02/21
10/02/21
DESIGN SKETCH
SITE AMENDMENTS
DW
DW
WORKING DRAWINGS ELEVATIONS C & D
EITHER WHOLLY OR IN PART, IN ANY FORM (GRAPHIC, Address:
ELECTRONIC OR MECHANICAL, INCLUDING C 24/02/21 WORKING DRAWINGS DW Date: 09/03/21
PHOTOCOPYING) WITHOUT THE PERMISSION OF CDS
DESIGN CONSULTANTS PTY LTD." D 09/03/21 CERTIFIER AMENDMENTS DW 21 NANNYGAI STREET Scale @ A3:
CDS
1 : 100 Drawn:
cdsdesignconsultants.com.au
Telephone: (07) 3219 3988
PO Box 455, Coorparoo QLD 4151
NOOSAVILLE Checked: ZK/FL
Email: [email protected] Project: Drawing No:
D
QBCC No. 81713 BDAA:5096-20 Mobile: 0413 127 282
© COPYRIGHT 2021
Document Set ID: 21419096
DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE. CONFIRM
ALL LEVELS AND DIMENSIONS ON SITE BEFORE COMMENCEMENT OF WORKS
Email: [email protected]
www.oneproperty.com.au NANNYGAI 3A Revision:
Version: 1, Version Date: 16/03/2021
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Response to Information Request - MCU1 0015 - Revised Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.