IMPORTANT NOTE: FOR ALL POST & BEAM
SETOUTS, REFER TO CONSTRUCTION DETAILS
IMPORTANT NOTE: ALL EXHAUST FANS TO BE B
DUCTED EXTERNALLY TO EAVE/SOFFIT
IMPORTANT NOTE: PROVIDE STUDS AT 300MM C A
OFF BACK WALL ADJACENT TO OVERHEAD
CUPBOARDS AND ALL SHELVING TO ALLOW D
FOR SIDE FIXING
PROVIDE TERMIMESH PROTECTION
ALL WINDOWS TO BE @ 2400MM HEAD HEIGHT 18120 210
UNLESS NOTED OTHERWISE
90 6610 90 7210 90 3940 90
BALCONY BED 1
1000 2010 90 1000 90 960 90 880 90 1000
HOUSE TYPE A VOID LIFT P. VOID
300 300 5115
ALFRESCO 25.13 m²
460
DP DP SA0816 SA0816 SA0816 DP
BALCONY 37.30 m²
170
90
90
590
GARAGE 45.24 m²
1000
90 1000
HALLWAY
820*
2700MM CEILING HT
820-08SL*
TIMBER
LOWER LIVING 51.60 m² 17
2330
QL2136/4 2700HH
860 90 410
16
UPPER LIVING 89.29 m²
SERVICES
15
BALCONY
VOID
VOID
14
1360
40MM STEP
BED 1
BED 1
3720
248.56 m² TILES 13 LIFT
CARPET
VOID
VOID PROV.
2420
12
5960
GYPROCK LINED
90
90 510 90
11
820*
5500
SERVICES
CEILING 10
ROBE
90 1000
720*
VOID
R
VOID
1100
9
BALCONY
8
6980
5800
6800
820 CSD* 7
90
90
6
5
450
1 1
ROBE
ROBE
1400
4
1400
3
BATH 4 4
2120
BATH BED 2
950
WIR
BED 2
3660
90 TILES BED 3 CARPET
BED 3
3290
2 820 CSD*
CARPET
700 90
90
90
ENS
BATH
890 180
1800
1500
ENS
IMPORTANT NOTE: TILES
1300
1480
SHR
800
590
• ALL EXHAUST FANS TO BE DUCTED EXTERNALLY TO THE
EAVE/SOFFIT.
90
90
DP SA0816 SA0824 SA0824 SA0612
• FOR ALL POST & BEAM SET OUTS, REFER TO DP DP
1000
CONSTRUCTION DETAILS. 670 1545 2390 945
• PROVIDE STUDS AT 300mm OFF BACK WALL ADJACENT
TO OVERHEAD CUPBOARDS & SHELVING TO ALLOW FOR
SIDE FIXING
• ALL STAIR TREAD SURFACES OR NOSING STRIP TO BE 410 90 910 90 51090 3010 1930 90 1000 800 90 3050
SLIP RESISTANT IN ACCORDANCE WITH NCC TABLE
V. R. ROBE WIR
3.9.1.1 90 120
• ALL DOORS TO WC, POWDER ROOM & ENSUITE WC TO 90 4510 90 2200 90 2820 90 1000 90 3020 90 2720 180 1040 90
BE FITTED WITH LIFT OFF HINGES IN ACCORDANCE WITH BALCONY BED 3 HALL BED 2 ENS SHR
NCC 3.8.3 4120 1000
• HARDWIRED INTERCONNECTED SMOKE DETECTOR TO
BE LOCATED @ MIN. 300mm FROM BULKHEADS/WALLS
WITH BATTERY BACK UP as per NCC 3.7.2 & to comply with
AS3786.
ENERGY EFFICIENCY TO COMPLY WITH NCC 3.12 (ENERGY
RATING OF 6.0 STARS).
FIRST FLOOR A
SINGLE STOREY: Scale 1 : 100
• WALL SISALATION AND R1.5 BATTS TO EXT WALLS
• R3.5 BATTS TO ROOF SPACE (INCL. GARAGE &
ALFRESCO)
• CEILING FAN TO ALFRESCO
• 2X ROOF VENTILATORS
GENERAL NOTES:
• 3X VENTED EAVE SHEETS * DENOTES 2340H INTERNAL DOORS
2340H INTERNAL DOORS TO GROUND FLOOR
ONLY & WINDOW HEAD HEIGHTS 2143mm
FLOOR WASTE LOCATION
SMART WASTE INSERT TILE GRATE LOCATION
(UNLESS NOTED OTHERWISE)
DOUBLE STOREY:
HARDWIRED INTERCONNECTED SMOKE G GAS POINT
• WALL SISALATION AND R1.5 BATTS TO GROUND & FIRST DETECTOR(S) TO BE LOCATED @ MIN. 300mm
FLOOR FROM BULKHEADS/WALLS WITH BATTERY
BACKUP as per BCA 3.7.2 & to comply with
CAPPED COLD WATER POINT TO FRIDGE SPACE. REFER
TO DETAIL.
• R3.5 BATTS TO ROOF SPACE (INCL. GARAGE & AS3786 F
ALFRESCO) ASSUMES LIGHT COLOUR WINDOW DENOTES ENGINEER DESIGNED BEAM. RV ROOF VENTILATOR LOCATION
*EDB (REFER TO ENGINEERS DETAILS)
COVERINGS BY OWNER & LIGHT COLOUR ROOF AT TIME
ALL STAIR TREAD SURFACES OR NOSING STRIP TO BE SLIP
OF CONSTRUCTION. MH MANHOLE LOCATION RESISTANT IN ACCORDANCE WITH BCA TABLE 3.9.1.1
• CEILING FAN TO ALFRESCO DP DOWNPIPE LOCATION DOORS TO WC, POWDER ROOM, WC & ENSUITE WC, TO BE
• 2X ROOF VENTILATORS FITTED WITH LIFT OFF HINGES IN ACCORDANCE WITH B.C.A. 3.8.3
AC DUCT LOCATION (GENERALLY 300mm
• 3X VENTED EAVE SHEETS DIA.)
HOUSE TYPE A
Rev Date Amendment Init Stage: Drawing Title:
"THIS WORK IS OWNED BY CDS DESIGN CONSULTANTS
PTY LTD, AND CANNOT BE REPRODUCED OR COPIED,
A
B
05/02/21
10/02/21
DESIGN SKETCH
SITE AMENDMENTS
DW
DW
WORKING DRAWINGS FIRST FLOOR
EITHER WHOLLY OR IN PART, IN ANY FORM (GRAPHIC, Address:
ELECTRONIC OR MECHANICAL, INCLUDING C 24/02/21 WORKING DRAWINGS DW Date: 09/03/21
PHOTOCOPYING) WITHOUT THE PERMISSION OF CDS
DESIGN CONSULTANTS PTY LTD." D 09/03/21 CERTIFIER AMENDMENTS DW 21 NANNYGAI STREET Scale @ A3:
CDS
As indicated Drawn:
cdsdesignconsultants.com.au
Telephone: (07) 3219 3988
PO Box 455, Coorparoo QLD 4151
NOOSAVILLE Checked: ZK/FL
Email: [email protected] Project: Drawing No:
D
QBCC No. 81713 BDAA:5096-20 Mobile: 0413 127 282
© COPYRIGHT 2021
Document Set ID: 21419096
DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE. CONFIRM
ALL LEVELS AND DIMENSIONS ON SITE BEFORE COMMENCEMENT OF WORKS
Email: [email protected]
www.oneproperty.com.au NANNYGAI 2A Revision:
Version: 1, Version Date: 16/03/2021
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Response to Information Request - MCU1 0015 - Revised Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.