NOTES:
unit 5, the hastings, noosa parade
lot 5 on GTP1154
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN
- DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010
APPROVED PLAN RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12
51983.3225.10 4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM
NOOSA COUNCIL JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
90 1 AUGUST 2017 90
3710
70
960
70
1660
90
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH
2270 830
AS 1684.2 2010
1209DH 0906AW 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE
OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH
existing internal space
MANUFACTURERS SPECIFICATIONS.
880
proposed pantry 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS
2520
EXIST AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS
840
existing cross bracing
L'DRY 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO
RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED
11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN
UP
EXISTING
existing first floor STANDARDS RELATING TO HIS OR HER OWN WORK
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000
CARPORT
close off opening, remove wc and
vanity to make as pantry and DOMESTIC SMOKE ALARMS:
2109DH
entry from kitchen side 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED WITH
existing 90x90shs posts PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE
SAFETY LEGISLATION AMENDMENT REGULATION 2016
2121OXSD 2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE WITH AS
1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL AND INTERCOM
Existing Ground Existing First Floor balcony SYSTEMS.
3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD WIRED
(EXISTING DWELLINGS ONLY) THAT CANNOT BE
REMOVED FROM DEVICE
NOTE: SMOKE ALARMS TO BE INSTALLED IN ALL HALLWAYS AND BEDROOMS
TO EXISTING RESIDENCE
90 70 70 90
3710 960 1660
existing windows to remain
0906AW 0906AW 0906AW
divide bathroom close off opening
make as 2 rooms
remove existing
cupboard
bed bed
Elevation 1 - a
02 of 04
2109DH 2109DH
Existing Upper Floor
existing floor
Elevation 2 - a
existing carport
02 of 04
Elevation 1 - a
Elevation 2 - a
PROPOSED: CLIENT: PAUL TEYCHENNE BUILDER: MICK GARDNER MANDY'S DESIGN & DRAFTING SHEET: 2 of 4 DATE: ISSUE NO:
BUILD IN GROUND+ALTERATIONS PH: 0414 697 882 PH: 0403 481 474 SCALE: 1:100 JULY 2017 A
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - Compiled Approved Plans - 51983.3225.17.pdfRelated documentApplication case desk ↗
About this file
- File size
- 47.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.