Council archive · source document
SUPERSEDED - Compiled Approved Plans - 51983.3225.17
Plans and drawings: the text below has words only, no drawings.
Very large file (47.3 MB): may take a few minutes to open.
Original PDF page 83, section 1. The text section number identifies this passage in the reader.
NOOSA COUNCIL
APPROVED PLAN
5193.3225.16 13 NOV 2023
[OCR of page images]
NOTE
UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION
WORKS, REFER TO PROPOSED FLOOR PLAN FOR
PROPOSED RECONFIGURATION LAYOUT, WALL
SETOUT DIMENSIONS AND OPENING LOCATIONS.
ADJOINING PROPERTY
(SHOPPING CENTRE)
SITE BOUNDARY
- -
ADJOINING
VILLA
vA
ADJOINING
VILLA
\
ADJOINING
VILLA ADJOINING
VILLA
(01. \ PROPOSED PLAN - LEVEL 1
a, SCALE 1:100
NOTES
1. ALL CONSTRUCTION WORK UNDERTAKEN
IS TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT
AUSTRALIAN STANDARDS AND
APPLICABLE LOCAL AUTHORITY
REQUIREMENTS.
2. ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION.
a
NOTE:
THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER
TO STRUCTURAL ENGINEER'S DETAILS
FOR ALL MEMBER SIZES, SPECIFICATIONS
AND SITE SPECIFIC STRUCTURAL
REQUIREMENTS.
NOTE:
ROOM DIMENSIONS
SHOWN ARE TO
FINISHED WALL FACES.
LEGEND
AW AWNING WINDOW
COL STEEL COLUMN
CT COOKTOP
DHW DOUBLE HUNG WINDOW
DP =DOWNPIPE
DRY CLOTHES DRYER
FW — FLOOR WASTE
DW DISHWASHER
FGW FIXED GLASS WINDOW
HB HAND BASIN
LVW LOUVRE WINDOW
OV OVEN
P PANTRY
REF REFRIGERATOR
SGD SLIDING GLASS DOOR
SGW_ SLIDING GLASS WINDOW
SHR SHOWER
SWP SANITARY WASTE PIPE
we TOILET
WM WASHING MACHINE
NOOSA COUNCIL
APPROVED PLAN
5193.3225.16 13 NOV 2023
NoTEs: AMENDMENTS
1. THIS IS A COMPUTER GENERATED DRAWING. DO NOT AMEND BY HAND. REV DATE
THIS DRAWING SHOWS DFSIGN INTENT ONY AI DIMENSIONS AND
SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION,
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS
ARE TO BE REPORTED TO THE DESIGNER PRIOR TO CONSTRUCTION.
PROJECI
PROPOSED RESIDENTIAL ALTERATIONS
ADDRESS
DESCRIPTION BY
A [30.06.2023] ISSUE FOR DEVELOPMENT APPROVAL GB
DRAWING CREATED
AUG 2022 1:100
PROJECT NO. REVISION
SCALE @ AS
www.gtgroup.net.au
21021 A
DWG.NO.
DA013
GT GROUP
[email protected]
0410 063 172
(COD YLT Rott]
4, DO NOT SCALE THIS DRAWING,
COPYRIGHT:
‘© GT GROUP BUILDING DCSIGN. TIICSC DRAWINGS ARC PROTECTED DY
‘THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.
3/30 HASTINGS STREET, NOOSA HEADS QLD 4567
DRAWING
PROPOSED PLAN - LEVEL 1
| AUTHOR: GB.
| ORIGINAL SHEET SIZE: A3 [420x297mm]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - Compiled Approved Plans - 51983.3225.17.pdfRelated documentApplication case desk ↗