NOOSA COUNCIL
APPROVED PLAN
51983.3225.17
27 NOV 2023
[OCR of page images]
ADJOINING |
VILLA _
BOUNDARY ADJOINING
7 VILLA
BOUNDARY
(DEDICATED LOT
EXCLUSIVE USE AREA)
ADJOINING
VILLA
ROADWAY
BOUNDARY
ENSUITE
2860x1920mm
TILE
BED 1
4200x2800mm
CARPET
OUNDARY
770
BED 2
4200x2780mm
CARPET
ADJOINING
__ Sf SHARED
BOUNDARY ROADWAY
aa
(DEDICATED LOT
EXCLUSIVE USE AREA)
ENSUITE
2380x1920mm
TILE
7
ADJOINING
SHARED
ROADWAY
(01. \ PROPOSED PLAN - LEVEL 1
YT) SCALE 1:100
NOTE
UNLESS NOTED OTHERWISE, ALL EXISTING
BUILT WORKS ARE TO REMAIN. FOR FURTHER
CLARIFICATION ON EXTENT OF DEMOLITION
WORKS, REFER TO PROPOSED FLOOR PLAN FOR
PROPOSED RECONFIGURATION LAYOUT, WALL
SETOUT DIMENSIONS AND OPENING LOCATIONS.
NOTES
1. ALL CONSTRUCTION WORK UNDERTAKEN
IS TO COMPLY WITH THE NATIONAL
CONSTRUCTION CODE (BCA), RELEVANT
AUSTRALIAN STANDARDS AND
APPLICABLE LOCAL AUTHORITY
REQUIREMENTS.
2. ALL SETBACK/SETOUT DIMENSIONS ARE
TO BE CHECKED AND VERIFIED ON SITE
PRIOR TO CONSTRUCTION,
THESE DRAWINGS ARE DESIGN CONCEPTS
ONLY AND SHALL NOT BE USED IN ANY
WAY FOR STRUCTURAL PURPOSES. REFER
TO STRUCTURAL ENGINEER'S DETAILS
FOR ALL MEMBER SIZES, SPECIFICATIONS
AND SITE SPECIFIC STRUCTURAL
REQUIREMENTS.
NOTE:
ROOM DIMENSIONS
SHOWN ARE TO
FINISHED WALL FACES.
LEGEND
AW AWNING WINDOW
COL STEEL COLUMN
CT COOKTOP
DHW DOUBLE HUNG WINDOW
DP DOWNPIPE
DRY CLOTHES DRYER
FW FLOOR WASTE
DW DISHWASHER
FGW FIXED GLASS WINDOW
HB HAND BASIN
LVW LOUVRE WINDOW
OV OVEN
P PANTRY
REF REFRIGERATOR
SGD SLIDING GLASS DOOR
SGW SLIDING GLASS WINDOW
SHR SHOWER
SWP SANITARY WASTE PIPE
wc TOILET
WM WASHING MACHINE
NOOSA COUNCIL
APPROVED PLAN
51983.3225.17
27 NOV 2023
2. THIS DRAWING SHOWS DESIGN INTENT ONLY. ALL DIMENSIONS AND REV DATE DESCRPTION
‘SETOUTS ARE TO BE CHECKED ON SITE PRIOR TO CONSTRUCTION. A | 04.07.2023 | ISSUE FOR DEVELOPMENT APPROVAL GB
3. ANY DISCREPANCIES OR OMISSIONS FOUND WITHIN THE DRAWINGS
PROJECT
g
DA ISSUE
PROPOSED RESIDENTIAL ALTERATIONS
2/30 HASTINGS STREET, NOOSA HEADS QLD 4567
‘ADDRESS
COPYRIGHT: | AUTHOR: GB DRAWING
© GT GROUP BUILDING DESIGN. THESE DRAWINGS ARE PROTECTED BY i omcnn SESE MI
THE LAWS OF COPYRIGHT AND MAY NOT BE COPIED OR REPRODUCED [ORIGINAL SHEET SIZE: A8;420x287m]__ | PROPOSED PLAN - LEVEL 1
WITHOUT THE WRITTEN PERMISSION OF GT GROUP BUILDING DESIGN.
DRAWING CREATED SCALE @ A3
AUG 2022 1:100
PROJECT NO, REVISION
22048 A
DW, NO.
DA013
GT GROUP
www.gtgroup.net.qu
[email protected]
era Ie
(07) 3298 6938
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - Compiled Approved Plans - 51983.3225.17.pdfRelated documentApplication case desk ↗
About this file
- File size
- 47.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.